TITLE

Gamma Inert Sterilization: A Solution to Polyethylene Oxidation?

AUTHOR(S)
Medel, Francisco J.; Kurtz, Steven M.; Hozack, William J.; Parvizi, Javad; Purtill, James J.; Sharkey, Peter F.; MacDonald, Daniel; Kraay, Matthew J.; Goldberg, Victor; Rimnac, Clare M.
PUB. DATE
April 2009
SOURCE
Journal of Bone & Joint Surgery, American Volume;Apr2009, Vol. 91-A Issue 4, p839
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: In the 1990s, oxidation was found to occur in ultra-high molecular weight polyethylene total joint replacement components following gamma irradiation and prolonged shelf aging in air. Orthopaedic manufacturers developed barrier packaging to reduce oxidation during and after radiation sterilization. The present study explores the hypothesis that polyethylene components sterilized in a low-oxygen environment undergo similar in vivo oxidative mechanisms as inserts sterilized in air. In addition, the potential influence of the different sterilization processes on the wear performance of the polyethylene components was examined. Methods: An analysis of oxidation, wear, and surface damage was performed for forty-eight acetabular liners and 123 tibial inserts. The mean implantation time was 12.3 ± 3.7 years for thirty-one acetabular liners that had been gamma sterilized in air and 4.0 ± 2.5 years for the seventeen acetabular liners that had been gamma sterilized in inert gas. The mean implantation time was 11.0 ± 3.2 years for the twenty-six tibial inserts that had been sterilized in air and 2.8 ± 2.2 years for the ninety-seven tibial inserts that had been gamma sterilized in inert gas. Oxidation and hydroperoxide levels were characterized in loaded and unloaded regions of the inserts. Results: Measurable oxidation and oxidation potential were observed in all cohorts. The oxidation and hydroperoxide levels were regional. Surfaces with access to body fluids were more heavily oxidized than protected bearing surfaces were. This variation appeared to be greater in historical (gamma-in-air-sterilized) components. Regarding wear performance, historical and conventional acetabular liners showed similarwear penetration rates, whereas a low incidence of delamination was confirmed for the conventional tibial inserts in the first decade of implantation. Conclusions: The present study explores the impact of industry-wide changes in sterilization practices for polyethylene. We found lower oxidation and oxidation potential in the conventional acetabular liners and tibial inserts that had been gamma sterilized in inert gas as compared with the historical components that had been gamma sterilized in air. However, we also found strong evidence that conventional components undergo mechanisms of in vivo oxidation similar to those observed following gamma irradiation in air. In addition, gamma sterilization in inert gas did not provide polyethylene with a significant improvement in terms of wear resistance as compared with gamma sterilization in air, except for a lower incidence of delamination in the first decade of implantation for tibial inserts. Clinical Relevance: Our research demonstrates that gamma inert sterilization may have improved, but not completely solved, the problem of polyethylene oxidation for hip and knee arthroplasty.
ACCESSION #
37614973

 

Related Articles

  • Soft-Tissue Resurfacing of the Glenoid in the Treatment of Glenohumeral Arthritis in Active Patients Less Than Fifty Years Old. Elhassan, Bassem; Ozbaydar, Mehmet; Duller, David; Higgins, Lawrence D.; Warner, Jon J. P. // Journal of Bone & Joint Surgery, American Volume;Feb2009, Vol. 91-A Issue 2, p419 

    Background: Soft-tissue resurfacing of the glenoid, with arthroplasty of the humeral head, has been proposed as a viable treatment option for younger patients with symptomatic osteoarthritis of the shoulder. The purpose of this study was to evaluate our results with soft-tissue resurfacing of...

  • Primary Total Hip Arthroplasty with a Porous-Coated Acetabular Component: A Concise Follow-up, at a Minimum of Twenty Years, of Previous Reports. Valle, Craig J. Della; Mesko, Nathan W.; Quigley, Laura; Rosenberg, Aaron G.; Jacobs, Joshua J.; Galante, Jorge O. // Journal of Bone & Joint Surgery, American Volume;May2009, Vol. 91-A Issue 5, p1130 

    We previously reported the seven and fifteen-year results of the use of a porous-coated acetabular metal shell inserted without cement in a consecutive series of 204 primary total hip arthroplasties. In the present study, we evaluated the longer-term outcomes of these arthroplasties at a minimum...

  • The Knee Arthroplasty Trial (KAT): Design Features, Baseline Characteristics, and Two-Year Functional Outcomes After Alternative Approaches to Knee Replacement. MacLennan, G. // Journal of Bone & Joint Surgery, American Volume;Jan2009, Vol. 91-A Issue 1, p134 

    Background: The aim of continued development of total knee replacement systems has been the further improvement of the quality of life and increasing the duration of prosthetic survival. Our goal was to evaluate the effects of several design features, including metal backing of the tibial...

  • Secondary Patellar Resurfacing after Primary Bicondylar Knee Arthroplasty did Not Meet Patients' Expectations. Correia, João; Sieder, Marc; Kendoff, Daniel; Citak, Mustafa; Gehrke, Thorsten; Klauser, Wolfgang; Haasper, Carl // Open Orthopaedics Journal;2012, Vol. 6, p414 

    Secondary patella resurfacing is a controversial procedure which is applied in patients with anterior knee pain after a bicondylar knee arthroplasty (with unresurfaced patella). A group of 46 patients were submitted to this procedure and their satisfaction, range of motion and pain improvement...

  • Metal Ion Measurement as a Diagnostic Tool to Identify Problems with Metal-on-Metal Hip Resurfacing. De Smet, K.; De Haan, R.; Calistri, A.; Campbell, P. A.; Ebramzadeh, E.; Pattyn, C.; Gill, H. S. // Journal of Bone & Joint Surgery, American Volume;Nov2008 Supplement 4, Vol. 90-A, p202 

    The article reports on the results of research which was conducted in an effort to determine if measurement of serum ion levels could be used as a diagnostic tool by correlating correlating blood and joint fluid metal ion measurements with findings of metallosis and component wear at the time of...

  • Patellofemoral Arthroplasty: A Systematic Review of the Literature. Tarassoli, Payam; Punwar, Shahid; Khan, Wasim; Johnstone, David // Open Orthopaedics Journal;2012 Special Issue 002, Vol. 6 Issue S2, p340 

    Identification and management of patients with isolated patellofemoral osteoarthritis are challenging. Many of these patients present at a young age and it is important to distinguish degenerative change in the patellofemoral articulation from the other various causes of anterior knee pain. Once...

  • IMPACTION GRAFTING IN REVISION TOTAL ELBOW ARTHROPLASTY. Loebenberg, Mark I.; Adams, Robert; O'Driscoll, Shawn W.; Morrey, Bernard F. // Journal of Bone & Joint Surgery, American Volume;Jan2005, Vol. 87-A Issue 1, p99 

    Background: Revision total elbow arthroplasty is often undertaken in patients who have severe osteolysis of both the distal part of the humerus and the proximal part of the ulna. To deal with such bone loss, we have adopted the practice of impaction grafting, which has become a well-established...

  • Knee arthrodesis with an intramedullary nail: a retrospective study. Vil, Jeroen; Almqvist, Karl; Vanheeren, Philippe; Boone, Barbara; Verdonk, René // Knee Surgery, Sports Traumatology, Arthroscopy;Aug2008, Vol. 16 Issue 7, p645 

    A group of 19 patients who underwent knee arthrodesis with use of an intramedullary nail between 1996 and 2005, was studied. In the majority of patients knee arthrodesis was performed as a salvage procedure for the limb following an infected total knee arthroplasty. The outcome of the procedure...

  • Relationship between the surgical epicondylar axis and the articular surface of the distal femur: an anatomic study. Lustig, Sébastien; Lavoie, Frédéric; Selmi, Tarik; Servien, Elvire; Neyret, Philippe // Knee Surgery, Sports Traumatology, Arthroscopy;Aug2008, Vol. 16 Issue 7, p674 

    Many authors presented the epicondylar axis as the fixed axis of rotation of the femoral condyles during flexion of the knee. Positioning of the femoral component of a total knee arthroplasty (TKA) based on the epicondyles has been proposed. This work is a critical analysis of this concept....

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics