ABSTRACT
Seven columns with embedded polar functionality were evaluated for use in liquid chromatography with a focus on molecular shape recognition. Tests based on Standard Reference Material 869b Column Selectivity Test Mixture for Liquid Chromatography and the Tanaka test indicate that only two of the phases are slightly shape selective at 20 °C. The shape recognition characteristics of the phases appear to be directly related to the density of the embedded polar ligands and the temperature of the separation, consistent with trends observed with conventional hydrocarbon phases.
ACCESSION #
37371680

 

Related Articles

  • LC Trouble Everywhere. Dolan, John W. // LC-GC Asia Pacific; 

    The article discusses some problems that students encountered on both conventional liquid chromatography (LC) and ultrahigh-pressure LC (UHPLC). One student asked if she could inject 5 µL of sample onto her UHPLC column without any problems. The rule is that one can inject ≈ 15% of the...

  • Development and validation of stability indicating UPLC assay method for bupivacaine in pharmaceutical formulation. PCHGS, Prathyusha.; Shanmugasundaram, P.; Naidu, P. Y.; Singamsetty, Sanjeev // Journal of Chemical & Pharmaceutical Research;2012, Vol. 4 Issue 11, p4702 

    The present method provides the detailed description of development and validation of a simple stability indicating liquid chromatographic method for Bupivacaine Assay in the presence of Methyl paraben. Successful separation of the drug from methyl paraben was achieved with in 6min on C18, 50 x...

  • LC Technologies Tackle Reproducibility. Sidawi, Danielle // R&D Magazine;Aug2004, Vol. 46 Issue 8, p26 

    Provides information on the use of liquid chromatography technology in maximizing reproducibility. Benefits offered by the technology; Elements of liquid chromatography; Implementation of the technology. INSET: GC/MS targets toxic dust.

  • A new affinity-HPLC packing for protein separation: Cibacron blue attached uniform porous poly(HEMA- co-EDM) beads. Unsal, Ender; Durdu, Aysun; Elmas, Begum; Tuncel, Murvet; Tuncel, Ali // Analytical & Bioanalytical Chemistry;Nov2005, Vol. 383 Issue 6, p930 

    In this study, a new affinity high-performance liquid chromatography (HPLC) stationary phase suitable for protein separation was synthesized. In the first stage of the synthesis, uniform porous poly(2-hydroxyethyl methacrylate- co-ethylene dimethacrylate), poly(HEMA- co-EDM), beads 6.2 �m...

  • How to Retain Polar and Nonpolar Compounds on the Same HPLC Stationary Phase with an Isocratic Mobile Phase. Pesek, Joseph J.; Matyska, Maria T. // LC-GC North America;Mar2006, Vol. 24 Issue 3, p296 

    The article focuses on the ways to retain polar and nonpolar compounds on the same high performance liquid chromatography phase with an isocratic mobile phase. stationary phases such as hydride silica-based can be a useful approach for the analysis of complex samples with a broad range of...

  • A Novel HPLC Silica-Based C18 Stationary Phase for Highly Acidic pH the SiliaChrom SB C18. Lévesque, Charles; Bédard, Vincent; Béland, François // LC-GC North America;Sep2009 Application Notebook, Vol. 27, p60 

    The article reports on the result of the study which assesses the effectiveness of SiliChrom SB C18 column in the analysis of acidic compounds. The study was conducted on SiliaChrom SB C18 μm phase where pH level and flow rate was evaluated through high performance liquid chromatography...

  • Orthogonal Selectivity of ZirChrom-CARB. Bingwen Yan; McNeff, Clayton // LC-GC North America;Sep2010 Supplement, Vol. 28, p66 

    The article examines the selectivity comparison of carbon-clad ZirChrom-CARB high performance liquid chromatography (HPLC) column against a typical silica bonded phase for 22 nonelectrolyte solutes with varying chemical properties. It mentions that the bonded-phase silicas in reversed-phase...

  • Comparison of Fully and Superficially Porous Particle Columns for the Analysis of Basic Compounds. Fountain, Kenneth J.; Xu, Jane; Zhe Yin; Iraneta, Pamela C.; Diehl, Diane M. // LC-GC Asia Pacific;Jun2009, Vol. 12 Issue 2, p1 

    The article discusses the improvements made to column stationary phases in high-performance liquid chromatography (HPLC). A discussion on HPLC columns with superficially porous particles is provided. The differences in separation performance between fully and superficially porous particle...

  • Pressure Stability of Wide-Pore Diameter Chiral Chromatography Columns. Cox, Geoffrey B.; Maier, Norbert M. // LC-GC North America;Sep2009 Application Notebook, Vol. 27, p21 

    The article reports on the result of the study which assesses the stability of wide-pore silica-based chiral stationary phases (CSP) to high pressures. The study was conducted on 3-μm and 5-μm columns using Agilent 1100 and 1200 high performance liquid chromatography (HPLC) systems. It was...