TITLE

Magnetic microbead-based electrochemical immunoassays

AUTHOR(S)
Kuramitz, Hideki
PUB. DATE
May 2009
SOURCE
Analytical & Bioanalytical Chemistry;May2009, Vol. 394 Issue 1, p61
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
This review provides a summary of recent works concerning electrochemical immunoassays using magnetic microbeads as a solid phase. Recent research activity has led to innovative and powerful detection strategies that have been resulted in sensitive electrochemical detection. Coupling of magnetic microbeads with highly sensitive electrochemical detection provides a useful analytical method for environmental evaluation and clinical diagnostics, etc. The huge surface area and high dispersion capability of magnetic microbeads strongly contributes towards the development of new sensitive, rapid, user-friendly, and miniaturized electrochemical immunoassay systems. Moreover, the immunocomplexes formed on the magnetic microbead surface can be easily detected without pretreatment steps such as preconcentration or purification, which are normally required for standard methods. The discussion in this review is organized in two main subjects that include magnetic-microbead-based assays using enzyme labels and nanoparticle tags. [Figure not available: see fulltext.]
ACCESSION #
37371678

 

Related Articles

  • Some Potential Pitfalls of Immunoassays. Hansen, Keith A. // South Dakota Medicine;May2012, p174 

    The author discusses the potential pitfalls of immunoassays. According to the author, the development of immunoassays has been dependent on the highly specific interaction between antibody and antigen. The author notes that inappropriate results can cause significant clinical decisions that can...

  • Electrochemoluminescent Immunoassay (ECLIA). Vohr, Hans-Werner // Encyclopedic Reference of Immunotoxicology;2005, p222 

    The article presents an encyclopedia entry for electrochemoluminescent immunoassay (ECLIA). It is an immunoassay in which a light-generating chemical reaction occurs during binding between a ruthenium tri-bispyridine-labeled analyte, captured in an antigen-antibody-bead complex and tripopylamine.

  • Evaluation of the Dade Behring Syva® EMIT 2000 tacrolimus assay on the Bayer Advia 1650. Stephen, DWS; Rooke, P; Clark, S; Coutts, M; Crowe, L; Docherty, D // Annals of Clinical Biochemistry;Nov2003, Vol. 40 Issue 6, p697 

    Background: The Dade Behring Syva® EMIT (enzyme multiplied immunoassay technique) method for the measurement of tacrolimus in whole blood was evaluated against the Abbott IMx® microparticle enzyme immunoassay (MEIA) method. EMIT measures tacrolimus colorimetrically, whereas MEIA measures...

  • Determination of Alachlor in food products by a fluorescence polarization immunoassay. Nartova, Yu. V.; Ermolaeva, T. N.; Fleisher, M. R.; Abuknesha, R.; Eremin, S. A. // Journal of Analytical Chemistry;May2008, Vol. 63 Issue 5, p499 

    A procedure for the determination of Alachlor in liquid media using a fluorescence polarization immunoassay (FPIA) was developed. The effects of the structure and purification degree of a tracer (analyte with a fluorescent label) on the analytical signals, sensitivity, and selectivity in the...

  • Direct electrochemical immunoassay based on a silica nanoparticles/sol—gel composite architecture for encapsulation of immunoconjugate. Fu-Chang Wang; Ruo Yuan; Ya-Qin Chai // Applied Microbiology & Biotechnology;Sep2006, Vol. 72 Issue 4, p671 

    A highly hydrophobic and non-toxic colloidal silica nanoparticle/polyvinyl butyral sol–gel composite membrane was prepared on a platinum wire electrode. With diphtheria-toxoid (D-Ag) as a model antigen and encapsulation of diphtheria antibody (D-Ab) in the composite architecture, this...

  • Immunoassays. Herzyk, Danuta J.; Vohr, Hans-Werner // Encyclopedic Reference of Immunotoxicology;2005, p325 

    A definition of the term "immunoassays" is presented. The term refers to methods applied in analyses of proteins also known as macromolecules. lmmunoassays as bioanalytical methods are based on formation of the specific antigen-antibody complex for detecting the presence and/or quantitation of...

  • Characteristics of a liposome immunoassay on a poly(methyl methacrylate) surface. Sang Youn Hwang; Yoichi Kumada; Gi Hoon Seong; Jaebum Choo; Shigeo Katoh; Eun Kyu Lee // Analytical & Bioanalytical Chemistry;Dec2007, Vol. 389 Issue 7/8, p2251 

    Liposome immunoassay (LIA) is based on enzyme immunoassay (EIA) but the detection sensitivity could be significantly enhanced by using antibody-coupled immunoliposomes encapsulating HRP (horse radish peroxidase). Here, we applied LIA to non-porous poly(methyl methacrylate) (PMMA) and polystyrene...

  • Displacement immunoassay for the detection of ochratoxin A using ochratoxin B modified glass beads. Lates, Vasilica; Yang, Cheng; Popescu, Ionel; Marty, Jean-Louis // Analytical & Bioanalytical Chemistry;Jun2012, Vol. 402 Issue 9, p2861 

    We report here the development of a new assay for the detection of ochratoxin A (OTA) based on the use of its dechlorinated analogue, ochratoxin B (OTB), in a displacement immunoassay. OTB was immobilised on controlled-pore glass beads followed by the binding of anti-OTA antibody, with anti-IgG...

  • Direct electrochemical immunoassay based on a silica nanoparticles/sol—gel composite architecture for encapsulation of immunoconjugate. Fu-Chang Wang; Ruo Yuan; Ya-Qin Chai // Applied Microbiology & Biotechnology;Sep2006, Vol. 72 Issue 4, p671 