TITLE

Improved manometric setup for the accurate determination of supercritical carbon dioxide sorption

AUTHOR(S)
van Hemert, Patrick; Bruining, Hans; Rudolph, E. Susanne J.; Wolf, Karl-Heinz A. A.; Maas, Jos G.
PUB. DATE
March 2009
SOURCE
Review of Scientific Instruments;Mar2009, Vol. 80 Issue 3, p035103
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
An improved version of the manometric apparatus and its procedures for measuring excess sorption of supercritical carbon dioxide are presented in detail with a comprehensive error analysis. An improved manometric apparatus is necessary for accurate excess sorption measurements with supercritical carbon dioxide due to the difficulties associated with the high sensitivity of density for pressure and temperature changes. The accuracy of the apparatus is validated by a duplicate measurement and a comparison with literature data. Excess sorption and desorption of CO2 on Filtrasorb 400 at 318.11 K up to 17 069 mole/m3 (15.474 MPa) were selected for this validation. The measured excess sorption maximums are 7.79±0.04 mole/kg at 2253 mole/m3 for the first sorption isotherm and 7.91±0.05 mole/kg at 2670 mole/m3 for its subsequent desorption isotherm. The sorption and desorption peaks of the duplicate experiment are 7.92±0.04 mole/kg at 2303 mole/m3 and 8.10±0.05 mole/kg at 2879 mole/m3, respectively. Both data sets show desorption data being higher than the sorption data of the same data set. The maximum discrepancy between the desorption and sorption isotherms of one data set is 0.15 mole/kg. The discrepancy between the two excess sorption isotherms is 0.12 mole/kg or less. The a priori error of the excess sorption measurements is between 0.02 and 0.06 mole/kg. The error due to He contamination is between 0.01 and 0.05 mole/kg. The difference between the a priori uncertainty and the observed maximum discrepancies is considered to be acceptable. The sorption isotherms show identical qualitative behavior as data in the literature. The quantitative behavior is similar but the peak height and the linear decrease in excess sorption at high gas densities are 10% higher. A plot of the excess sorption versus the density can be used to obtain the sorbed phase density and the specific micropore volume. These sorbed phase densities are in excellent agreement with the data in the literature. Furthermore, the excess sorption data scaled to this specific micropore volume in this work and in the literature collapse on a single curve when plotted versus gas density.
ACCESSION #
37259522

 

Related Articles

  • High Pressure Carbon Dioxide Pump.  // Product Design & Development;Nov/Dec2015, Vol. 70 Issue 9, p32 

    The article offers brief information on the SFT-10 liquid carbon dioxide pump from Supercritical Fluid Technologies.

  • Pressure applied to epoxy-potted samples by thermal contraction of the epoxy matrix. Lukefahr, H.G.; Collins, J.K.; Camacho, E.; Yeager, C.; MacLaughlin, D.E.; Myers, A.; Bernal, O.O. // Review of Scientific Instruments;Oct96, Vol. 67 Issue 10, p3642 

    Discusses the use of a cuprous oxide manometer in measuring the pressure applied to powdered cuprous oxide due to thermal contraction of an epoxy matrix commonly used for cryogenic nuclear magnetic resonance experiments. Overview on the experiment process and results.

  • Gravimetric/FT-IR apparatus for the study of vapor sorption on clay films. Tipton, T.; Johnston, C. T.; Trabue, S. L.; Erickson, C.; Stone, D. A. // Review of Scientific Instruments;Apr93, Vol. 64 Issue 4, p1091 

    An apparatus was built to collect simultaneous gravimetric and Fourier transform infrared sorption/desorption data on self-supporting clay films in a controlled-environment cell. This apparatus enables the masses of several sorbed species to be continuously monitored in situ. Its primary purpose...

  • Preparative SFC system.  // LC-GC North America;May2006, Vol. 24 Issue 5, p526 

    The article evaluates Thar's Supercritical Fluid Chromatography Prep 70 II system which is designed for the small-scale purification of both chiral and achiral compounds.

  • SFC columns for analytical and preparative applications.  // LC-GC Europe;Mar2009 Travelling Light, Vol. 22 Issue 3, p155 

    The article evaluates a line of supercritical fluid chromatography (SFC)-certified columns from Phenomenex Inc.

  • A new apparatus for the measurement of physical adsorption of gas mixtures at elevated pressures. Malbrunot, P.; Vidal, D.; Vermesse, J. // Review of Scientific Instruments;Jul1993, Vol. 64 Issue 7, p1984 

    The new apparatus described enables making simultaneously absolute measurements of physisorption, bulk density, and adsorption kinetics of multicomponent gas mixtures as a function of pressure up to 30 MPa. The method which combines the dynamic and the gravimetric methods is self-sufficient...

  • Improved double fluorescence detector for x-ray absorption spectroscopy. Heald, S. M. // Review of Scientific Instruments;Apr88, Vol. 59 Issue 4, p650 

    An improved double fluorescence detector for x-ray absorption spectroscopy is described and compared to a standard filter-slit detector.

  • Measurement of physical adsorption of gases at high pressure. Vidal, D.; Malbrunot, P.; Guengant, L.; Vermesse, J.; Bose, T. K.; Chahine, R. // Review of Scientific Instruments;Apr90, Vol. 61 Issue 4, p1314 

    A dielectric method is described for the measurement of physisorption of gases at pressures up to 200 MPa. The adsorption measurements of methane on activated carbon obtained at moderate pressures are in good agreement with precedent results but reveal unexpected negative values at higher pressures.

  • NEW MATERIALS AND COMPONENTS. Farmer, Barry L. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p258 

    Presents materials and components for scientific instruments and apparatus. Intelligent link; Noncontact milliammeter; Optical power meter; Moisture analysis; Pulse-delay generator; Optical mount; Lubricant; Phototherapy radiometer; Custom charge coupled devices; Miniature process manometer.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics