TITLE

Adaptive spatially resolving detector for the extreme ultraviolet with absolute measuring capability

AUTHOR(S)
Benk, Markus; Bergmann, Klaus
PUB. DATE
March 2009
SOURCE
Review of Scientific Instruments;Mar2009, Vol. 80 Issue 3, p033113
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A spatially resolving detector for the extreme ultraviolet (XUV) and soft x-ray spectral region is presented. Principle of operation is conversion of XUV radiation to visible light by a scintillator crystal. Luminescence is detected using charge coupled device camera and imaging optics. Single layer and multilayer coatings are applied to match the system to different spectral regions of interest. Field of view and spatial resolution can be adapted to the application. Calibration of the system enables to absolutely measure in-band radiation flux on the scintillator. The setup is designed for the characterization and optimization of XUV sources and XUV optical systems. Measurements, carried out to characterize the focus in a soft x-ray microscope, are presented as an application example.
ACCESSION #
37259481

 

Related Articles

  • Characterization of an x-ray framing camera utilizing a charge coupled device or film as recording media Logory, L.M.; Farley, D.R.; Conder, A.D.; Belli, E.A.; Bell, P.M.; Miller, P.L. // Review of Scientific Instruments;Dec1998, Vol. 69 Issue 12, p4054 

    Characterizes a charge coupled device camera system as a recording media. Applications of the electronic package and design of the camera system; Measurement on the contrast transfer function of the x-ray imager; Indications of the modulation transfer function plots of the device.

  • Quantitative measurement of x-ray images with a gated microchannel plate system in a z-pinch... Bing Shan; Yanagidaira, Takeshi; Shimoda, Katsuji; Hirano, Katsumi // Review of Scientific Instruments;Mar99, Vol. 70 Issue 3, p1688 

    Describes a multiframe, gated pinhole system capable of quantitative acquisition for pulsed soft x rays. System's basis on a gated microchannel plate (MCP); Observation of the evolution of z-pinch plasma in a plasma focus facility; Quantitative relationship between x-ray source intensity and...

  • A quarter waveplate for the polarization analysis close to the carbon K edge. Di Fonzo, Silvia; Jark, Werner // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1375 

    A recipe is presented for the optimization of quarter waveplates for the soft x-ray range constructed from multilayer transmission filters. The limitations are discussed in terms of stateof-the-art multilayer technology. A quarter waveplate with promising properties close to the carbon...

  • Double-crystal monochromator beam line on the Aladdin 1-GeV storage ring. Yang, B. X.; Middleton, F. H.; Olsson, B. G.; Bancroft, G. M.; Chen, J. M.; Sham, T. K.; Tan, K.; Wallace, D. J. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1355 

    We report the design, construction, and performance of a soft x-ray beam line with accessible photon energy 0.8–4.0 keV at the Synchrotron Radiation Center, University of Wisconsin–Madison. The beam line features an ultrahigh-vacuum (UHV) compatible high-precision double-crystal...

  • new products.  // Physics Today;May87, Vol. 40 Issue 5, p89 

    Introduces several scientific apparatus and instruments. Range of high-speed photodetectors by Instrument Technology Ltd.; Transient digitizer from Tektronix; Ultraviolet detector camera by Spectron Engineering.

  • Design and noise model for CCD-based, time-resolved PHA measurements. Schooff, R.; Diem, S.; Fonck, R.; Reinke, M.; Tritz, K. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p2007 

    A CCD pulse height analysis system is considered for the measurement of electron temperature on the Pegasus Toroidal Experiment. The first-generation CCD/PHA system will have one spatial point and obtain seven time points with a time resolution of 2.4 ms. Time resolution is achieved by shifting...

  • Precise measurement technology of soft-x-ray spectrum using dual transmission grating spectrometer. Jiamin Yang; Yaonan Ding; Wenghai Zhang; Jiyan Zhang; Zhijian Zheng // Review of Scientific Instruments;Oct2003, Vol. 74 Issue 10, p4268 

    A novel transmission grating spectrometer, called a dual-transmission grating spectrometer, has been designed and established. This spectrometer adopts two transmission gratings to disperse x rays twice, which suppresses the overlap of the grating higher-order diffraction, cuts out the transfer...

  • Calibration of charge coupled devices and a pinhole transmission grating to be used as elements... Schriever, G.; Lebert, R.; Naweed, A.; Mager, S.; Neff, W.; Kraft, S.; Scholze, F.; Ulm, G. // Review of Scientific Instruments;Sep97, Vol. 68 Issue 9, p3301 

    Investigates two charge coupled device (CCD) camera systems using two different chips. Charge coupled devices for soft x-ray detection; Characterization of the thinned back illuminated CCD camera; Characterization of the coated CCD camera; Comparison of the CCD types.

  • X-ray TV camera at 4.5 nm. Germer, R.; Meyer-Ilse, W. // Review of Scientific Instruments;Mar86, Vol. 57 Issue 3, p426 

    An imaging CCD (charge coupled device) camera for soft x-ray detection has been constructed. The principle used is the conversion of x-rays to visible light in a GdO[sub 2]S:Tb screen which covers the CCD surface. The achieved detective quantum efficiency was about 9% at the wavelength λ =...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics