TITLE

Effect of Incorrect Primer Application on Dentin Permeability

AUTHOR(S)
Cavalheiro, Alexandre; Vargas, Marcos A.; Armstrong, Steven R.; Dawson, Deborah V.; Gratton, David G.
PUB. DATE
November 2006
SOURCE
Journal of Adhesive Dentistry;2006, Vol. 8 Issue 6, p393
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Purpose: To evaluate in vitro the effect of clinical primer application errors on human dentin permeability. The null hypothesis is that there is no difference in dentin permeability reduction with the use of a total-etch three-step (TE3) dentin adhesive system among the treatment groups. Materials and Methods: Seventy extracted noncarious human third molars were sectioned to obtain 0.7-mm-thick midcoronal dentin disks. The specimens were randomly assigned to 5 groups and treated with a total-etch three-step (TE3) ethanol/water-based dentin adhesive system, Optibond FL (Kerr; Orange, CA, USA), according to manufacturer's instructions using 4 simulated application errors: short application of primer by immediate drying; no primer application; no drying of primer; aggressive drying of primer. Permeability of dentin was measured as fluid filtration at baseline and after adhesive polymerization. Kruskal-Wallis and Tukey's post-hoc comparisons were used to evaluate permeability reduction differences among groups (α = 0.05). Results: The null hypothesis was rejected (p < 0.0001). The data provided strong evidence that the distribution of percentage permeability reduction differed among the 5 treatment groups (p < 0.0001). All possible pairwise comparisons of the groups were statistically significant. The highest mean percentage of permeability reduction was observed in the group where manufacturer's instructions were followed (99.4 ± 1.0), followed by the aggressive drying primer group (86.7 ± 11.1), the shortened primer application group (73.01 ± 12.0), the no-drying primer group (48.44 ± 19.9), and, finally, the no-primer group (22.33 ± 7.7). Conclusion: The incorrect primer application allowed significant dentin permeability. Strict adherence to recommended clinical application of dentinal adhesives is fundamental to achieve good dentin tubule sealing.
ACCESSION #
36851955

 

Related Articles

  • Clinical Bonding of a Single-step Self-etching Adhesive in Noncarious Cervical Lesions. Van Dijken, Jan WV; Sunnegårdh-Grönberg, Karin; Sörensson, Ebba // Journal of Adhesive Dentistry;2007, Vol. 9 Issue 2, p241 

    Purpose: The aim of this study was to evaluate the clinical retention to dentin of a single-step self-etching adhesive system. Materials and Methods: A total of 133 Class V restorations were placed with the self-etching primer Xeno III and a resin composite (Tetric Ceram) or a polyacid-modified...

  • CURRENT CONCEPTS ON ADHESION TO DENTIN. Eick, J. D.; Gwinnett, A. J.; Pashley, D. H.; Robinson, S. J. // Critical Reviews in Oral Biology & Medicine;1997, Vol. 8 Issue 3, p306 

    This review examines fundamental concepts in bonding to dentin. Emphasis is placed on the structure and permeability characteristics of dentin and how they may influence its interaction with adhesive resin. Several new techniques to examine the interfaces between resin and dentin are reviewed...

  • Effect of Priming Time on Tensile Bond Strength to Bovine Teeth and Morphologic Structure of Interfaces Created by Self-Etching Primers. Itou, Kousuke; Torii, Yasuhiro; Takimura, Takehiko; Chikami, Kana; Ishikawa, Kunio; Suzuki, Kazuomi // International Journal of Prosthodontics;May/Jun2001, Vol. 14 Issue 3, p225 

    Purpose: The purpose of this study was to investigate the effect of priming time on bovine enamel and dentin adhesion promoted by self-etching primer systems. Materials and Methods: Two commercial self-etching primer systems, Clearfil SE Bond (SE) and Unifil Bond (UB), were used. Bovine enamel...

  • Bonding of Resin-based Luting Cements to Zirconia With and Without the Use of Ceramic Priming Agents. Koizumi, Hiroyasu; Nakayama, Daisuke; Komine, Futoshi; Blatz, Markus B.; Matsumura, Hideo // Journal of Adhesive Dentistry;2012, Vol. 14 Issue 4, p385 

    Purpose: This study evaluated and compared bonding characteristics of resin-based luting agents and special ceramic primers to zirconia. Materials and Methods: Disk specimens (n = 242) were fabricated from zirconium dioxide ceramics (Katana) and bonded with four resin-based luting agents without...

  • Phosphoric Acid/Sodium Hypochlorite Mixture as Dentin Conditioner: A New Approach. Nassif, Mohammed S.; El-Korashy, Dalia I. // Journal of Adhesive Dentistry;2009, Vol. 11 Issue 6, p455 

    Purpose: To investigate the effect of a phosphoric acid/sodium hypochlorite (NaOCl) mixture as a dentin conditioner on shear bond strength, the resin/dentin interface, as well as the surface area and tubular diameter of dentin. Materials and Methods: Thirty human molars were prepared for shear...

  • Improvement of Exposure Times: Effects on Adhesive Properties and Resin-Dentin Bond Strengths of Etch-and-Rinse Adhesives.  // Journal of Adhesive Dentistry;2011, Vol. 13 Issue 3, p235 

    Purpose: This study evaluated the effect of prolonged polymerization times on the microtensile resin-dentin bond strength (μTBS), degree of conversion of adhesive films (DC) and silver nitrate uptake (SNU) for an ethanol/water- (Adper Single Bond 2, [SB]) and an acetone-based (One Step Plus,...

  • Shear Bond Strength of Different Adhesives to Er:YAG Laser-prepared Dentin. Çelik, Esra Uzer; Ergücü, Zeynep; Türkün, L. Sebnem; Türkün, Murat // Journal of Adhesive Dentistry;2006, Vol. 8 Issue 5, p319 

    Purpose: The aim of this study was to examine the influence of Er:YAG laser on the shear bond strength of three different adhesives to lased dentin. Materials and Methods: Seventy specimens obtained from 35 extracted human molars were embedded in polyester resin and ground with silicon carbide...

  • Scanning electron microscopy examination of 3 different adhesive systems. de Cerqueria Luz, Maria Aparecida Alves; Arana-Chavez, Victor F.; Netto, Narciso Garone // Quintessence International;Oct2005, Vol. 36 Issue 9, p687 

    Objectives: The aim of this study was to compare the interaction of dentin with 2 different self-etch resin bonding systems, as well as with a total-etch resin bonding system. Method and materials: Nine recently extracted, unerupted third molars, roots, and occlusal thirds were used. A...

  • In Vitro Microleakage of Dentin Adhesives. Sorensen, John A.; Dixit, Neeta V.; White, Shane N.; Avera, Sean P. // International Journal of Prosthodontics;May/Jun1991, Vol. 4 Issue 3, p213 

    This in vitro study measured the microleakage of current dentin bonding agents and glass-ionomer bases. Freshly extracted human molars were prepared to a flat surface, and dentin adhesives and composite resins were applied in a plastic matrix. Samples were stored in water at 37�C,...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library