Three-dimensional Finite Element Stress Analysis of a Cuneiform-Geometry Implant

Cruz, Mauro; Wassall, Thomaz; Toledo, Elson Magalhães; da Silva Barra, Luis Paulo; de Castro Lemonge, Afonso Celso
September 2003
International Journal of Oral & Maxillofacial Implants;Sep/Oct2003, Vol. 18 Issue 5, p675
Academic Journal
Purpose: The biomechanical behavior of an osseointegrated dental implant plays an important role in its functional longevity inside the bone. Studies of this aspect of dental implants by the finite element method are ongoing. In the present study, a cuneiform-geometry implant was considered with a 3-dimensional model that had a mesh that was finer than in the models commonly found in the literature. Materials and Methods: A mechanical model of an edentulous mandible was generated from computerized tomography, with the implant placed in the left first premolar region. A 100-N axial load was applied at the implant abutment, and the mandibular boundary conditions were modeled considering the real geometry of its muscle supporting system. The cortical and trabecular bone was assumed to be homogeneous, isotropic, and linearly elastic. Results: The stress analysis provided results that were used to plot global and detailed graphics of normal maximum (S1), minimum (S3), and von Mises stress fields. The results obtained were analyzed and compared qualitatively with the literature. Discussion: Quantitative comparisons were not performed because of basic differences between the model adopted here and those used by other authors. The stress distribution pattern for the studied geometry was similar to those found in the current literature, but insignificant apical stress concentration occurred. The stress concentration occurred at the neck of the implant, ie, in the cortical bone, which was similar to results for other implant shapes reported in the literature. Conclusion: The studied geometry showed a smooth stress pattern, with stress concentrated in the cervical region. The values, however, were within the range of values found in the cortical layer far from the implant, caused by the muscular action. No significant stress concentration was found in the apical area.


Related Articles

  • In Situ Tooth Replica Custom Implant: A 3-Dimensional Finite Element Stress and Strain Analysis. Ghuneim, Wael Aly // Journal of Oral Implantology;Oct2013, Vol. 39 Issue 5, p558 

    This study is a phase of a biomechanical study, a part of a research program concerned with the new concept of in situ tooth replication. The purpose of the study was to evaluate tooth replica under each of two possible circumstances: (1) attachment via periodontal ligament and (2)...

  • Biomechanics of the press-fit phenomenon in dental implantology: an image-based finite element analysis. Frisardi, Gianni; Barone, Sandro; Razionale, Armando V.; Paoli, Alessandro; Frisardi, Flavio; Tullio, Antonio; Lumbau, Aurea; Chessa, Giacomo // Head & Face Medicine;2012, Vol. 8 Issue 1, p18 

    Background: A fundamental pre-requisite for the clinical success in dental implant surgery is the fast and stable implant osseointegration. The press-fit phenomenon occurring at implant insertion induces biomechanical effects in the bone tissues, which ensure implant primary stability. In the...

  • Analysis of Stress and Strain Around Orthodontically Loaded Implants: An Animal Study. Cattaneo, Paolo M.; Dalstra, Michel; Melsen, Birte // International Journal of Oral & Maxillofacial Implants;Mar/Apr2007, Vol. 22 Issue 2, p213 

    Purpose: The aim of this study was to describe the stress and strain fields around orthodontically loaded dental implants using the finite element method and to evaluate the relationship between the generated strain and the biologic reaction expressed through histomorphometric parameters....

  • Three dimensional finite element analysis of a novel osteointegrated dental implant designed to reduce stress peak of cortical bone. ZHENG, LI; YANG, JINGSONG; HU, XUEFENG; LUO, JIAOMING // Acta of Bioengineering & Biomechanics;2014, Vol. 16 Issue 3, p21 

    A new type of dental implant was designed as multi-component mainly including inset and abutment between which a gap was introduced to guide the force to transmit from the cancellous bone to cortical bone, with the intention to lower the stress peak at cortical bone. By way of finite element...

  • Effect of Model Parameters on Finite Element Analysis of Micromotions in Implant Dentistry. Winter, Werner; Klein, Daniel; Karl, Matthias // Journal of Oral Implantology;Feb2013, Vol. 39 Issue 1, p23 

    Micromotion between dental implant and bony socket may occur in immediate-loading scenarios. Excessive micromotion surpassing an estimated threshold of approximately 150 µm may result in fibrous encapsulation instead of osseointegration of the implant. As finite element analysis (FEA) has...

  • Ultimate Masticatory Force as a Criterion in Implant Selection. Demenko, V.; Linetskiy, I.; Nesvit, K.; Shevchenko, A. // Journal of Dental Research;Oct2011, Vol. 90 Issue 10, p1211 

    Osseointegrated implants often fail because of excessive masticatory forces that cause extremely large stresses in bone tissue. We hypothesized that a proper dental implant could be selected by comparing the ultimate masticatory forces of a wide range of commercially available implants. We...

  • The Relationship of Bone Resorption Around Dental Implants to Abutment Design: A Preliminary 1-Year Clinical Study. Hasan, Istabrak; Heinemann, Friedhelm; Bourauel, Christoph // International Journal of Prosthodontics;2011, Vol. 24 Issue 5, p457 

    The influence of abutment design on bone resorption around immediately loaded and osseointegrated implants used to support fixed partial prostheses was investigated in a 1-year study. One hundred ten implants were placed in 24 anterior partially edentulous maxillae. The probing depths of each...

  • ONE PIECE IMPLANT. Saluja, B. S.; Mittal, Divya // Guident;2012, Vol. 5 Issue 3, p26 

    During the last two decades, implant treatment has become one of the first options for the prosthetic rehabilitation of completely edentulous and partially edentulous jaws. Slow and steady shift of paradigm from conventional two pieces, two stage implantology to unibody single stage implantology...

  • A Retrospective Clinical Study of Wide-Diameter Implants Used in Posterior Edentulous Areas. Mordenfeld, Maud Hultin; Johansson, Anders; Hedin, Måns; Billström, Camilla; Fyrberg, Kristina Arvidson // International Journal of Oral & Maxillofacial Implants;May/Jun2004, Vol. 19 Issue 3, p387 

    Purpose: The purpose of this study was to examine retrospectively the outcome of wide-diameter dental implants used to retain fixed restorations in the posterior segments of the maxilla and mandible. Materials and Methods: Fifty-two patients were consecutively treated between 1997 and 2000 with...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics