TITLE

Measurement of the energy distribution of an intense electron beam in an external magnetic field

AUTHOR(S)
Myers, M. C.; Swanekamp, S. B.; Friedman, M.; Hegeler, F.
PUB. DATE
February 2009
SOURCE
Review of Scientific Instruments;Feb2009, Vol. 80 Issue 2, pN.PAG
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
An energy analyzer device has been developed which utilizes a series of stacked foils and Rogowski current monitors to the measure time resolved current of an intense electron beam. The energy distribution of the electron beam is unfolded from measured current ratios using computer simulations. This device is particularly useful where electron beams are guided by external magnetic fields which may make other electron energy measurement techniques difficult. This technique was used to determine the energy distribution of a 550 keV, 95 kA electron beam as it propagates in the gas mixture of a high power KrF laser. The resulting energy distributions at various depths in the gas are in agreement with three-dimensional particle-in-cell simulations providing confidence in the measurement technique.
ACCESSION #
36823153

 

Related Articles

  • Velocity spread measurements on a magnetron injection gun beam. Guss, W. C.; Basten, M. A.; Kreischer, K. E.; Temkin, R. J. // Journal of Applied Physics;9/15/1994, Vol. 76 Issue 6, p3237 

    Reports on the measurement of the parallel electron velocity distribution function on an electron beam from a magnetron injection gun using an E/B energy analyzer. Illustration of the gycotron with source, magnetic field coils and cavity.

  • Study of the magnetic analyzer of relativistic helical electron beams. Zaitsev, N.; Ilyakov, E.; Kulagin, I.; Shevchenko, A. // Radiophysics & Quantum Electronics;Feb2006, Vol. 49 Issue 2, p120 

    The paper presents the results of studying the analyzer of helical electron beams experimentally. The analyzer is based on separation of electron velocity fractions in the adiabatically growing magnetic field. Optimization of the analyzer design to minimize the amount of electrons reflected from...

  • A magnetic analyzer of a helical electron beam based on a controlled magnetic mirror. Gvozdev, A.; Zaitsev, N.; Zapevalov, S.; Ilyakov, E.; Fiks, A.; Shevchenko, A. // Instruments & Experimental Techniques;Mar2011, Vol. 54 Issue 2, p230 

    magnetic analyzer of a helical subrelativistic electron beam formed by a three-electrode magnetron-injector gun in the field of a cryomagnet is described. Electrons are separated in transverse velocities by a magnetic field adiabatically increasing along the beam direction. The analyzer was used...

  • Observation of multiple-peaked structure in the time-of-flight spectrum of the Sinp-tokamak... Ray, N.R. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p971 

    Focuses on a multiple-peaked structure in the time-of-flight (TOF) spectrum obtained in a TOF analyzer system in the Sinp-tokamak. Explanation of the nature of the measured TOF spectrum; Study of the particle diffusion across the magnetic field as a result of acceleration by the dynamic...

  • Compact floating ion energy analyzer for measuring energy distributions of ions bombarding... Edelberg, Erik A.; Perry, Andrew; Benjamin, Neil; Aydil, Eray S. // Review of Scientific Instruments;Jun99, Vol. 70 Issue 6, p2689 

    Describes the design and construction of a compact floating retarding-field ion energy analyzer and the accompanying electronics for use in the measurement of the energy distribution of ions bombarding radio-frequency biased electrodes in high-density plasma reactors. Main components of the...

  • New Display-type Analyzer for Three-dimensional Fermi Surface Mapping and Atomic Orbital Analysis. Takahashi, Nobuaki; Matsui, Fumihiko; Matsuda, Hiroyuki; Shigenai, Shin; Hirama, Yoshiteru; Hamada, Yoji; Nakanishi, Koji; Namba, Hidetoshi; Kitamura, Toshiro; Soejima, Hiroyoshi; Daimon, Hiroshi // AIP Conference Proceedings;2007, Vol. 879 Issue 1, p1180 

    We have developed and installed a new Display-type ANAlyzer (DIANA) at Ritsumeikan SR center BL-7. We measured the angle-integrated energy distribution curve of poly-crystal gold and the photoelectron intensity angular distribution (PIAD) of HOPG to estimate the total energy resolution and to...

  • Tailored Particle Beams From Single-Component Plasmas. Weber, T. R.; Danielson, J. R.; Surko, C. M. // AIP Conference Proceedings;3/30/2009, Vol. 1114 Issue 1, p171 

    Recently, we developed a non-destructive technique to create narrow beams of electrons (or positrons) of adjustable width and brightness from single-component plasmas confined in a Penning-Malmberg trap [Weber et al., Phys. Plasmas 13, 123502 (2008)]. Here, we review highlights of that work and...

  • Magnetic Phase Diagram of the Quasi-Two-Dimensional S = 1/2 Antiferromagnet Cs2CuBr4. Tsujii, H.; Rotundu, C. R.; Ono, T.; Andraka, B.; Tanaka, H.; Takano, Y. // AIP Conference Proceedings;2006, Vol. 850 Issue 1, p1093 

    Cs2CuBr4 is one of the best candidates for the spin-1/2 Heisenberg antiferromagnet on the triangular lattice. To date, it is the only spin-1/2 material in which a magnetization plateau has been observed at 1/3 of the saturation magnetization — the hallmark of the triangular-lattice...

  • A thin-film second-order gradiometer with integrated dc-SQUID. Carelli, P.; Castellano, M. G.; Chiaventi, L.; Leoni, R.; Cirillo, M.; Modena, I. // Journal of Applied Physics;9/15/1993, Vol. 74 Issue 6, p4194 

    Presents a study which fabricated and characterized a superconducting planar gradiometer sensitive to the second-order spatial derivative of the magnetic field. Sensitivity in the flux-locked-loop and in open-loop mode; Measurement of the magnetic isoflux line distribution generated by a...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics