TITLE

Control of hysteretic behavior in flux concentrators

AUTHOR(S)
Trindade, I. G.; Leitão, D. C.; Pogorelov, Y.; Sousa, J. B.; Chaves, R. C.; Cardoso, S.; Freitas, P. P.
PUB. DATE
February 2009
SOURCE
Applied Physics Letters;2/16/2009, Vol. 94 Issue 7, pN.PAG
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The magnetic states of flux concentrators (FCs), consisting of poles and yokes with lateral dimensions in the range of 100 μm and integrating either single layer films of amorphous alloys of Cox(Zr–Nb)1-x with x=90 and x=88 or a synthetic antiferromagnet (SAF) of (NiFe/Ru)xn, are analyzed by Bitter pattern and magnetic force microscopy. Magnetic field sensors, placed in the gap of the FC by microfabrication processes, exhibited magnetoresistive responses strongly correlated with the magnetic states of the FC. The hysteresis of the field produced by the FC is reduced to a minimum when the SAF is used.
ACCESSION #
36797994

 

Related Articles

  • Variable magnetic field and temperature magnetic force microscopy. Mohanty, J.; Engel-Herbert, R.; Hesjedal, T. // Applied Physics A: Materials Science & Processing;Nov2005, Vol. 81 Issue 7, p1359 

    Magnetic force microscopy (MFM) studies of epitaxial MnAs films on GaAs(001) have been performed as a function of the applied magnetic field and the sample temperature. For this purpose, we combined a stable variable-temperature sample stage with a compact magnet assembly to fit a commercial...

  • Measurement of magnetic near field on a coplanar waveguide using a MFM tip. Endo, Yasushi; Watanabe, Masatoshi; Mitsuzuka, Yoshio; Shimada, Yutaka; Yamaguchi, Masahiro // Journal of Applied Physics;Apr2011, Vol. 109 Issue 7, p07D326 

    This paper proposes a method to measure the ac magnetic field distribution in close proximity to a coplanar waveguide (CPW) employing a cantilever tip fabricated for magnetic force microscopy as a sensor. Almost the entire surface of the tip is coated with a magnetically hard film (Co-Cr-Pt),...

  • Direction detectable static magnetic field imaging by frequency-modulated magnetic force microscopy with an AC magnetic field driven soft magnetic tip. Saito, Hitoshi; Ito, Ryoichi; Egawa, Genta; Li, Zhenghua; Yoshimura, Satoru // Journal of Applied Physics;Apr2011, Vol. 109 Issue 7, p07E330 

    Direction detectable static magnetic field imaging, which directly distinguishes the up and down direction of static perpendicular magnetic field from a sample surface and the polarity of magnetic charges on the surface, was demonstrated for CoCrPt-SiO2 perpendicular magnetic recording media...

  • Flux trapping in a macroscopic cylinderical hole drilled in Bi-Sr-Ca-Cu-O. Kiliç, A.; Kiliç, K.; Yetiç, H.; Olutaç, M.; Altinkok, A.; Sözeri, H.; Çetin, O. // European Physical Journal B -- Condensed Matter;Apr2006, Vol. 50 Issue 4, p565 

    The flux dynamics in a polycrystalline sample of Bi1.7Pb0.3Sr2Ca2Cu3Ox with a macroscopic cylindrical hole (CH) drilled was investigated by slow transport relaxation (V-t curves) and magnetovoltage measurements (V-H curves). It was monitored that there are several discontinuities in the time...

  • Measurement of in-plane magnetization by force microscopy. Abraham, David W.; Williams, C. C.; Wickramasinghe, H. K. // Applied Physics Letters;10/10/1988, Vol. 53 Issue 15, p1446 

    We present data which show that the magnetic force microscope is capable of detecting the component of the magnetic field parallel to the surface of a sample under study. Images of bits in a Co-alloy thin-film disk and of laser-written bits in a TbFe film were taken with a magnetized tip tilted...

  • Quantitative analysis of transition curvature by magnetic force microscopy. Liu, Feng; Li, Shaoping; Liu, Yan; Gray, George; Schultz, Allan // Journal of Applied Physics;5/15/2002 Part 1, 2 & 3, Vol. 91 Issue 10, p6842 

    A technique, based on magnetic force microscopy (MFM), has been developed to quantify the curvature of recording written transitions. By evaluating the phase deviation and coherence of MFM imaged recording tracks, the on-track transition curvature can be precisely measured to nanometer level or...

  • Observation of thermal switching of a single ferromagnetic particle. Lederman, M.; Gibson, G. A.; Schultz, S. // Journal of Applied Physics;5/15/1993, Vol. 73 Issue 10, p6961 

    Focuses on a magnetic force microscope which could detect fields emanating from submicrometer permalloy particles with magnetic moments. Data on the angular dependence of the switching field; Dynamics of switching close to the switching field.

  • Vortex State Suppression in a Hexagonal Array of Interacting Py Triangular Rings. SPIZZO, F.; PATRIGNANI, L.; BISERO, D.; VAVASSORI, P.; METLUSHKO, V. // Acta Physica Polonica, A.;Feb2013, Vol. 123 Issue 2, p218 

    We investigate the effect of magnetostatic interactions on the magnetization reversal process of equilateral triangular rings arranged on a hexagonal lattice. Inter-ring interactions originate as rings corners host domain- -walls that produce an intense dipolar field; the effect of such...

  • A NEW METHOD BASED ON THE SPECTRAL ANALYSIS TO GENERATE THE FREQUENTIAL BEHAVIOR OF MAGNETIC HYSTERESIS. Nouicer, A.; Nouicer, E.; Feliachi, M. // Progress in Electromagnetics Research M;Sep2011, Vol. 19, p53 

    The aim of the paper is to present a simple but well applicable development, to generate the waveform of the magnetic flux density, and so the magnetic hysteresis, for any signal frequency. The proposed approach is based on the knowledge of the signal spectrum for one given frequency. It allows...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics