Utility of Intraoperative Three-Dimensional Imaging at the Hip and Knee Joints with and without Navigation

AUTHOR(S)
Hüfner, Tobias; Stübig, Timo; Citak, Musa; Gösling, Thomas; Krettek, Christian; Kendoff, Daniel
PUB. DATE
February 2009
SOURCE
Journal of Bone & Joint Surgery, American Volume;Feb2009 Supplement 1, Vol. 91-A Issue S1, p33
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Intraoperative three-dimensional imaging in orthopaedic trauma care has achieved greater importance over the last few years in some specialized hospital centers. For various types of peripheral-extremity trauma, clinical studies have confirmed, on the basis of three-dimensional information, an intraoperative revision rate ranging from 7% to 19%. Three-dimensional C-arm imaging may be used to achieve adequate intraoperative information about the quality of fracture reduction, residual steps, and correct implant placement, and this technique has been described for use in both the hip joint (for acetabular fractures, isolated femoral head [Pipkin-type] fractures, three-dimensional navigated sacroiliac screw or acetabular column screw placements, and, less frequently, for navigated drilling of tumors or osteochondral lesions) and the knee joint (for tibial plateau fractures, complex distal femoral condylar fractures, and navigated targeting of osteochondral lesions in combination with the use of preoperative magnetic resonance imaging scans). Major limitations of this technology include increased intraoperative time requirements, limited image quality compared with that of computed tomographic scans, cost, specific positioning techniques, and the need for radiolucent operating-room tables. Although prospective studies have yet to be conducted, the ways in which the surgeon will benefit from the use of intraoperative three-dimensional imaging are apparent, but indications for combined three-dimensional C-arm navigated procedures at the hip and knee joint are still limited. Future directions may include the use of digital flat-panel detectors and even robotic-controlled C-arm motion.
ACCESSION #
36656918

 

Related Articles

  • 3D video-based deformation measurement of the pelvis bone under dynamic cyclic loading.  // BioMedical Engineering OnLine;2011, Vol. 10 Issue 1, p60 

    The article presents a study which described the application of dynamic 3D-deformation measurement using a three-dimensional (3D) video motion capturing (MoCap) system to gain data for the development of complex orthopaedic oncological implants around the hip joint of the pelvis including the...

  • 3D isotropic turbo spin-echo intermediate-weighted sequence with refocusing control in knee imaging: comparison study with 3D isotropic fast-field echo sequence. Jung Min Seo; Young Cheol Yoon; Jong Won Kwon // Acta Radiologica;Dec2011, Vol. 52 Issue 10, p1119 

    Three-dimensional (3D) turbo spin-echo (TSE) images have been used in imaging of the extremities and comparable diagnostic performance to two-dimensional (2D) TSE images has been reported in several studies. However, comparison of the 3D isotropic TSE intermediate-weighted sequence and 3D FFE...

  • MAGNETIC RESONANCE IMAGING COMPARISON OF LATERAL COLLATERAL LIGAMENT AND PATELLAR TENDON LENGTH. NJAGULJ, Vesna; KOVAČEV, Nemanja; RAŠOVIĆ, Predrag; SEMNIC, Robert; MILANKOV, Miroslav Z. // Medicinski Pregled / Medical Review;jul/avg2014, Vol. 67 Issue 7/8, p197 

    Introduction. The problem of using patellar tendon auto or allografts for lateral collateral ligament reconstruction results in the occurrence of ligaments mismatch. The length of patellar tendon does not match the lateral collateral ligament. Material and Methods. Out of 151 patients, who...

  • A fully automated human knee 3D MRI bone segmentation using the ray casting technique. Dodin, Pierre; Martel-Pelletier, Johanne; Pelletier, Jean-Pierre; Abram, François // Medical & Biological Engineering & Computing;Dec2011, Vol. 49 Issue 12, p1413 

    This study aimed at developing a fully automated bone segmentation method for the human knee (femur and tibia) from magnetic resonance (MR) images. MR imaging was acquired on a whole body 1.5T scanner with a gradient echo fat suppressed sequence using an extremity coil. The method was based on...

  • High Resolution T1ρ Mapping of In Vivo Human Knee Cartilage at 7T. Singh, Anup; Haris, Mohammad; Cai, Kejia; Kogan, Feliks; Hariharan, Hari; Reddy, Ravinder // PLoS ONE;May2014, Vol. 9 Issue 5, p1 

    Purpose: Spin lattice relaxation time in rotating frame (T1ρ) mapping of human knee cartilage has shown promise in detecting biochemical changes during osteoarthritis. Due to higher field strength, MRI at 7T has advantages in term of SNR compared to clinical MR scanners and this can be used...

  • Rotational alignment in patient-specific instrumentation in TKA: MRI or CT? Silva, Alcindo; Pinto, Elisabete; Sampaio, Ricardo // Knee Surgery, Sports Traumatology, Arthroscopy;Nov2016, Vol. 24 Issue 11, p3648 

    Purpose: To compare CT-guided and MRI-guided patient-specific instrumentation in total knee arthroplasty (TKA).Methods: Forty-four patients underwent primary TKA using either CT-guided or MR-guided Signatureâ„¢ patient-specific instrumentation. They were...

  • Patellar sleeve fracture. Nath, Priya I.; Lattin Jr., Grant E. // Pediatric Radiology;Dec2010, Vol. 40, p53 

    The article focuses on a patellar sleeve fracture diagnosed using magnetic resonance imaging (MRI) on a 14-year-old boy, who suffered a knee pain while running.

  • Osteochondral Lesions of Major Joints. Durur-Subasi, Irmak; Durur-Karakaya, Afak; Yildirim, Omer Selim // Eurasian Journal of Medicine;Jun2015, Vol. 47 Issue 2, p138 

    This paper provides information about osteochondral lesions (OCL) and example cases of OCL occurring in major joints, some of which are rarely seen. This simple tutorial is presented in question and answer format.

  • Asymmetrical bilateral traumatic hip dislocation in an adult with bilateral acetabular fracture. Sahin, Ozgur; Ozturk, Cagatay; Dereboy, Ferit; Karaeminogullari, Oguz // Archives of Orthopaedic & Trauma Surgery;Oct2007, Vol. 127 Issue 8, p643 

    This case report aims at presenting a unique case of simultaneous bilateral traumatic dislocation with right side anterior and the left side posterior together with bilateral acetabular fracture. Under general anesthesia, closed reduction of both hips was carried out. The case presented...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics