TITLE

Minimal Invasive PHILOS®-Plate Osteosynthesis in Proximal Humeral Fractures

AUTHOR(S)
Acklin, Yves P.; Jenni, Raphael; Walliser, Martin; Sommer, Christoph
PUB. DATE
February 2009
SOURCE
European Journal of Trauma & Emergency Surgery;Feb2009, Vol. 35 Issue 1, p35
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The anterior delto-pectoral approach is the standard approach for the fixation of proximal humeral fractures with the PHILOS®-Plate system. However, this approach can impair the vascular supply and can increase avascular necrosis. The objective of this study was to evaluate the results and complexity of surgery of proximal humeral fractures with a minimal invasive (MIPO) approach. All PHILOS®-plate osteosynthesis operated between Januray 2003 and June 2006 were evaluated prospectively. A minimal invasive antero-lateral deltasplit-approach was performed in all two to four fragment instable fractures meeting the indication for osteosynthesis according to Neer. An open approach (ORIF) was chosen in all other fractures mainly dislocated fractures and particularly in fractures with major subcapital displacement. A cohort of 68 patients suffered a proximal humerus fracture and qualified for a minimal invasive approach with a PHILOS®-plate osteosynthesis. Of these 68 patients, 41 were locally resident. Eight patients refused a follow-up, two patients were in constant care, and two patients died; 29 patients (71%) (20 females, 9 males) could be documented entirely with a median age of 64 years. The median operation time amounted to 75 min with a fluoroscopic time of 160 s. The median Constant score was 78 after 12 months. All fractures healed in adequate time. One patient showed a lesion of the ventral part of the axillary nerve. No patient suffered an avascular necrosis. The minimal invasive PHILOS® plate osteosynthesis through an antero-lateral delta-split approach proved to be an elegant procedure for selected fractures of the proximal humerus with a low morbidity and good functional outcome.
ACCESSION #
36502889

 

Related Articles

  • Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures. Zettl, Ralph; Müller, Thorben; Topp, Tobias; Lewan, Ulrike; Krüger, Antonio; Kühne, Christian; Ruchholtz, Steffen // International Orthopaedics;Aug2011, Vol. 35 Issue 8, p1245 

    Objective: The development of locking plate systems has led to polyaxial screws and new plate designs. This study compares monoaxial head locking screws (PHILOS© by Synthes) and a new generation of polyaxial locking screws (NCB-LE© by Zimmer) with respect to biomechanical stability....

  • Internal fixation of proximal humeral fractures with locking proximal humeral plate (LPHP) in elderly patients with osteoporosis. Roop Singh; Rajesh Rohilla; Virender Kadian; Sukhbir Sangwan; Manjeet Dhanda // Journal of Orthopaedics & Traumatology;Sep2008, Vol. 9 Issue 3, p149 

    Abstract Background  Different operative techniques used for treating displaced proximal humeral fractures could result in malunion, non-union, osteonecrosis of humeral head, loosening of screw and loss of reduction particularly in comminuted and osteoporotic fractures. Locking compression...

  • Internal fixation of proximal humeral fractures with a Polarus humeral nail. Yoichi Koike; Tatsuro Komatsuda; Katsumi Sato // Journal of Orthopaedics & Traumatology;Sep2008, Vol. 9 Issue 3, p135 

    Abstract Background  Proximal humeral fractures occur frequently. Displaced or unstable fractures require open reduction and internal fixation. Our objective was to investigate the clinical and radiographic results of the internal fixation using Polarus humeral nails for fractures of the...

  • Biological osteosynthesis of complex proximal humerus fractures: surgical technique and results from a prospective single center trial. Gavaskar, Ashok S.; Muthukumar, S.; Chowdary, Naveen // Archives of Orthopaedic & Trauma Surgery;May2010, Vol. 130 Issue 5, p667 

    Locked plating for complex proximal humerus fractures through a deltopectoral incision can be difficult due to the fracture morphology and need for fixed angle screws. Although good results have been reported with the deltopectoral approach; technical difficulties, excessive soft tissue...

  • OPEN REDUCTION AND INTERNAL FIXATION OF HUMERAL NONUNIONS. Rubel, Iván F.; Kloen, Peter; Campbell, Deirdre; Schwartz, Mark; Liew, Alan; Myers, Elizabeth; Helfet, David L. // Journal of Bone & Joint Surgery, American Volume;Aug2002, Vol. 84-A Issue 8, p1315 

    Background: Several studies have compared different methods for fixation of the midpart of the humeral shaft, but there are only scattered data regarding which type of plate construct provides the best fixation for humeral nonunion. The objectives of this study were (1) to obtain objective data...

  • Open Reduction and Internal Fixation of Three and Four-Part Fractures of the Proximal Part of the Humerus. Wijgman, A.J.; Roolker, W.; Patt, T.W.; Raaymakers, E.L.F.B.; Marti, R.K. // Journal of Bone & Joint Surgery, American Volume;Nov2002, Vol. 84-A Issue 11, p1919 

    Background: Controversy persists concerning the preferred treatment of displaced fractures of the proximal part of the humerus. The present study was undertaken to evaluate the results of open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus...

  • OPEN REDUCTION AND INTERNAL FIXATION OF DELAYED UNIONS AND NONUNIONS OF FRACTURES OF THE DISTAL PART OF THE HUMERUS. Helfet, David L.; Kloen, Peter; Anand, Neel; Rosen, Howard S. // Journal of Bone & Joint Surgery, American Volume;Jan2003, Vol. 85-A Issue 1, p33 

    Background: The purpose of the present retrospective study was to evaluate the results of open reduction and internal fixation of delayed unions and nonunions of fractures of the distal part of the humerus. Methods: Between 1976 and 2001, fifty-two patients with a delayed union (thirteen...

  • Arthroscopic assisted removal of screws from proximal humeral locking plates. Dattani, Rupen; Patel, Vipul R. // International Journal of Shoulder Surgery;Jul-Sep2013, Vol. 7 Issue 3, p125 

    A letter to the editor is presented which describes a method for removal or exchange of prominent screws from proximal humeral locking plates during osteosynthesis.

  • Management of proximal humeral fractures in elderly patients with uni- or polyaxial locking osteosynthesis system. Hong-fei Shi; Jin Xiong; Yi-xin Chen; Jun-fei Wang; Shou-feng Wang; Zhi-jun Chen; Yong Qiu // Archives of Orthopaedic & Trauma Surgery;Apr2011, Vol. 131 Issue 4, p541 

    Introduction: To evaluate the clinical efficacy of uni- and polyaxial locking osteosynthesis systems in the management of proximal humeral fractures in elderly patients, totally 76 cases were reviewed including 18 cases of two-part (Neer classification), 36 cases of three-part, and 22 cases of...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.