TITLE

The advanced ion-milling method for preparation of thin film using ion slicer: Application to a sample recovered from diamond-anvil cell

AUTHOR(S)
Tateno, Shigehiko; Sinmyo, Ryosuke; Hirose, Kei; Nishioka, Hideo
PUB. DATE
January 2009
SOURCE
Review of Scientific Instruments;Jan2009, Vol. 80 Issue 1, pN.PAG
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The advanced argon ion-milling technique using a new instrument called ion slicer was newly developed for preparation of thin foil. Compared to the conventional ion-milling methods, this technique facilitates very wide area to be homogeneously thinned by rocking the ion beam source with low angle and the specimen during milling. Here we applied this technique to a sample recovered from a laser-heated diamond-anvil cell (DAC). We obtained the thin film of almost entire cross section of the DAC sample along the compression axis, which possesses of ∼(10×50) μm2. The laser-heated sample is often heterogeneous due to a large temperature gradient. However the chemical analyses are obtained from the whole hot spot under the transmission electron microscope by preparing the thin foil using the ion slicer.
ACCESSION #
36425917

 

Related Articles

  • Physics update. S.G.B. // Physics Today;Jul96, Vol. 49 Issue 7, p9 

    Reports on the demonstration of multiple-beam ion channeling in crystals at the University of Oxford. Information on crystal quality from channelling patterns.

  • Synthesis and compressibility of Ti3(Al,Sn0.2)C2 and Ti3Al(C0.5,N0.5)2. Manoun, Bouchaib; Saxena, S. K.; Hug, Gilles; Ganguly, A.; Hoffman, E. N.; Barsoum, M. W. // Journal of Applied Physics;6/1/2007, Vol. 101 Issue 11, p113523 

    In this paper we report on the synthesis of a composition, Ti3Al(C0.5,N0.5)2, belonging to the Mn+1AXn family of ternary layered carbides and nitrides. X-ray and selected area diffraction confirm that this compound is isostructural with Ti3SiC2; its a and c-lattice parameters are 3.0404(5) and...

  • Determination of beam affected area and degradation of cathodoluminescence in GaAs induced by focused ion beam irradiation. Furuya, Kazuo; Saito, Tetsuya // Journal of Applied Physics;8/1/1996, Vol. 80 Issue 3, p1922 

    Presents information on a study which determined the beam affected area of n-type gallium arsenide, induced by the focused ion beam irradiation and the corresponding degradation in cathodoluminescence in a focused ion beam-interfaced transmission electron microscope. Background of the study;...

  • Transmission ERDA in Air with 15 MeV 4He Ions. Ishigami, Ryoya; Ito, Yoshifumi; Yasuda, Keisuke; Sasase, Masato; Hatori, Satoshi // AIP Conference Proceedings;2003, Vol. 680 Issue 1, p474 

    In-air transmission ERDA analysis was demonstrated using 15 MeV 4He beam in the W-MAST in Japan. The 4He beam was extracted into air through a molybdenum foil with thickness of 5 μm. The diameter of the 4He beam was about 2 mm after penetration through the foil. Titanium hydride TiHx and...

  • The Paths of Plurally Scattered Ions in Heavy Ion Elastic Recoil Detection Analysis. Franich, R.D.; Johnston, P.N.; Bubb, I.F. // AIP Conference Proceedings;2003, Vol. 680 Issue 1, p385 

    HIERDA spectra are complicated by the pronounced broadening and tailing effects that arise from the frequent plural and multiple scattering undergone by swift heavy ions in solids. The quantitative evaluation of these spectra is dependent on a clear understanding of the contribution of plurally...

  • Status and Perspectives of a Forward Scattering Project for the Multielemental Analysis of Liquids. Liendo, J.A.; González, A.C.; Fletcher, N.R.; Caussyn, D.D. // AIP Conference Proceedings;2003, Vol. 680 Issue 1, p377 

    A project based on low mass multielemental analysis of liquid samples by using forward elastic scattering is under progress. Elastic cross section measurements for the reactions 13 MeV 6,7Li +A and 24 MeV 16O +A, A being any nucleus lighter than Na, are necessary due to the existence of...

  • PROZA and CALIBRATION CURVES for Quantitative X-Ray Microanalysis of Biological Samples. Tylko, Grzegorz; Banach, Zuzanna; Kilarski, Wincenty // Microchimica Acta;Mar2004, Vol. 144 Issue 4, p271 

    The main scope of our work was to investigate the usefulness of the PROZA correction method and CALIBRATION CURVE construction for quantitative X-ray microanalysis of biological soft, freeze-dried tissues. The test samples with a known elemental concentration of NaCl, MgCl2, KH2PO4 and Na2SO4...

  • Scanning electron microscopy & coatings analysis. Germani, Mark S. // Paint & Coatings Industry;Jun98, Vol. 14 Issue 6, p102 

    Describes the scanning electron microscope with emphasis on the instrumental parameters that are most important for successful coating analysis. Ability to provide high magnification images of a sample on a micrometer-size scale; Use in the determination of the cause of coating failure and...

  • The importance of dust material in urban soil formation: the experience on study of two young Technosols on dust depositions. Prokof'eva, Tatiana; Kiryushin, Alexey; Shishkov, Vassiliy; Ivannikov, Feodor // Journal of Soils & Sediments: Protection, Risk Assessment, & Rem;Feb2017, Vol. 17 Issue 2, p515 

    Purpose: The volume of dust deposition on the soil surface in Moscow is big enough and make several tens of grams per square meter annually. The role of dust as a soil-forming material is especially high in places with practically no other soil parent materials. It is necessary to consider solid...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics