TITLE

A broadband absorption spectrometer using light emitting diodes for ultrasensitive, in situ trace gas detection

AUTHOR(S)
Langridge, Justin M.; Ball, Stephen M.; Shillings, Alexander J. L.; Jones, Roderic L.
PUB. DATE
December 2008
SOURCE
Review of Scientific Instruments;Dec2008, Vol. 79 Issue 12, p123110
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A broadband absorption spectrometer has been developed for highly sensitive and target-selective in situ trace gas measurements. The instrument employs two distinct modes of operation: (i) broadband cavity enhanced absorption spectroscopy (BBCEAS) is used to quantify the concentration of gases in sample mixtures from their characteristic absorption features, and (ii) periodic measurements of the cavity mirrors’ reflectivity are made using step-scan phase shift cavity ringdown spectroscopy (PSCRDS). The latter PSCRDS method provides a stand-alone alternative to the more usual method of determining mirror reflectivities by measuring BBCEAS absorption spectra for calibration samples of known composition. Moreover, the instrument’s two modes of operation use light from the same light emitting diode transmitted through the cavity in the same optical alignment, hence minimizing the potential for systematic errors between mirror reflectivity determinations and concentration measurements. The ability of the instrument to quantify absorber concentrations is tested in instrument intercomparison exercises for NO2 (versus a laser broadband cavity ringdown spectrometer) and for H2O (versus a commercial hygrometer). A method is also proposed for calculating effective absorption cross sections for fitting the differential structure in BBCEAS spectra due to strong, narrow absorption lines that are under-resolved and hence exhibit non-Beer–Lambert law behavior at the resolution of the BBCEAS measurements. This approach is tested on BBCEAS spectra of water vapor’s 4v+δ absorption bands around 650 nm. The most immediate analytical application of the present instrument is in quantifying the concentration of reactive trace gases in the ambient atmosphere. The instrument’s detection limits for NO3 as a function of integration time are considered in detail using an Allan variance analysis. Experiments under laboratory conditions produce a 1σ detection limit of 0.25 pptv for a 10 s acquisition time, which improves with further signal averaging to 0.09 pptv in 400 s. Finally, an example of the instrument’s performance under field work conditions is presented, in this case of measurements of the sum of NO3+N2O5 concentrations in the marine boundary layer acquired during the Reactive Halogens in the Marine Boundary Layer field campaign.
ACCESSION #
35982683

 

Related Articles

  • Application of a continuous-wave tunable erbium-doped fiber laser to molecular spectroscopy in the near infrared. Cousin, J.; Masselin, P.; Chen, W.; Boucher, D.; Kassi, S.; Romanini, D.; Szriftgiser, P. // Applied Physics B: Lasers & Optics;May2006, Vol. 83 Issue 2, p261 

    Development of a continuous-wave tunable fiber laser-based spectrometer for applied spectroscopy is reported. Wide wavelength tunability of an erbium-doped fiber laser (EDFL) was investigated in the near-infrared region of 1543–1601 nm. Continuous mode-hop free fine frequency tuning has...

  • A single source femtosecond-millisecond broadband spectrometer. Carroll, E. C.; Hill, M. P.; Madsen, D.; Malley, K. R.; Larsen, D. S. // Review of Scientific Instruments;Feb2009, Vol. 80 Issue 2, pN.PAG 

    Time-resolved measurement of population dynamics extending over femtosecond to millisecond time scales typically requires a combination of transient absorption techniques involving different laser systems and detection schemes. The spectrometer design presented here facilitates transient...

  • Diode arrays may light up compact spectrometers. Sobczynski, R.; Porter, J.L. // Laser Focus World;Mar95, Vol. 31 Issue 3, p75 

    Reports on the possible use of light-emitting diodes (LEDs) in compact spectrometers. Development of a near-infrared Fourier transform spectrometer, by D.O.M. Associates, that uses an array of light-emitting diodes (LEDs) and has no moving parts; LED modulation process.

  • Exciton localization and the Stokes' shift in InGaN epilayers. Martin, R.W.; Middleton, P.G. // Applied Physics Letters;1/11/1999, Vol. 74 Issue 2, p263 

    Reports on a comparative study of the emission and absorption spectra of a range of commercial InGaN light-emitting diodes and epilayers. Definition proposed for the form of the absorption edge for alloys.

  • A SIMPLE SPECTRO-COLORIMETER. Holden, Henry Francis // Australian Journal of Experimental Biology & Medical Science;Dec1927, Vol. 4 Issue 4, p221 

    The article describes the spectro-colorimeter, an instrument used for the rapid optical estimation of substances whose solutions show well-defined absorption bands in the visible region of the spectrum. The instrument may also be used for the estimation of the concentration of globin in a...

  • MERIS albedo climatology for FRESCO+O2 A-band cloud retrieval. Popp, C.; Wang, P.; Brunner, D.; Stammes, P.; Zhou, Y.; Grzegorski, M. // Atmospheric Measurement Techniques;2011, Vol. 4 Issue 3, p463 

    The article presents a study on a global albedo climatology for Oxygen A-band cloud retrievals based on MEdium Resolution Imaging Spectrometer (MERIS) Albedomap data. The study also discusses the favourable impact of MERIS for Fast Retrieval Scheme for Clouds from the Oxygen A-band (FRESCO+)...

  • Laboratory spectroscopic calibration of infrared tunable laser spectrometers for the in situ sensing of the Earth and Martian atmospheres. Zeninari, V.; Parvitte, B.; Joly, L.; Le Barbu, T.; Amarouche, N.; Durry, G. // Applied Physics B: Lasers & Optics;Nov2006, Vol. 85 Issue 2/3, p265 

    This paper reports the laboratory spectroscopic calibration of near- and mid- infrared tunable laser spectrometers used to determine in situ trace gases in the middle atmosphere of the Earth or in development for the investigation of the Martian atmosphere. The use of infrared absorption...

  • Online monitoring of ethane traces in exhaled breath with a difference frequency generation spectrometer. Halmer, D.; Thelen, S.; Hering, P.; Mürtz, M. // Applied Physics B: Lasers & Optics;Nov2006, Vol. 85 Issue 2/3, p437 

    We report a transportable mid-infrared laser cavity leak-out spectrometer for online detection of trace gases. The laser spectrometer is based on continuous-wave difference-frequency generation in the wavelength region around 3 μm. Sensitive spectroscopic trace gas monitoring was achieved...

  • Characterization of a derivative photoacoustic spectrometer. Guo, Lina; Tang, Zhilie; He, Yongheng; Zhang, Hanchao // Review of Scientific Instruments;Feb2007, Vol. 78 Issue 2, p024302 

    A design of derivative photoacoustic spectrometer is presented in this article. It mainly includes a wavelength-intensity splitter and a complementary chopper. In our design, a dual wavelength derivative method is introduced to implement a derivative operation. Through the wavelength-intensity...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics