TITLE

Parameters to Maximize 2f2-f1 Distortion Product Otoacoustic Emission Levels

AUTHOR(S)
Horn, Jennifer H.; Pratt, Sheila R.; Durrant, John D.
PUB. DATE
December 2008
SOURCE
Journal of Speech, Language & Hearing Research;Dec2008, Vol. 51 Issue 6, p1620
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Purpose: Past research has established parameters for the 2f1-f2 distortion product otoacoustic emissions (DPOAEs) that enhance response levels (e.g., L1 -- L2 = 10 dB; f2/f1 = 1.22; L1, L2 = 65, 55 dB SPL). These same parameters do not optimize 2f2-f1 DPOAEs. Therefore, this study was conducted to evaluate more completely those parameters that produce the most robust 2f2-f1 output. Method: Input--output functions of the 2f2-f1 component were obtained from 20 normal-hearing adults (with f2 = 2000 Hz and 4000 Hz). Frequency ratios, level differences, and overall sound levels were manipulated with parameter combinations chosen to expand on information established in previous studies. The DPOAE signal-to-noise ratio (SNR), response presence, and output levels were measured. Results: In general, mean SNRs and 2f2-f1 levels were greater, and DPOAEs were present more often for 2000 than for 4000 Hz across all parameter combinations. No single parameter combination resulted in pronounced maxima for 2f2-f1, which is consistent with past studies but is in sharp contrast to results for the more familiar 2f1-f2. Conclusions: Overall, the results suggest that to maximize the 2f2-f1 level, lower test frequencies, low frequency ratio, essentially equal levels of primary tones, and moderate stimulus levels are best, and such parameters might be important for applying DPOAE measurement to assessment of normal and impaired auditory function.
ACCESSION #
35974480

 

Related Articles

  • Distortion Product Otoacoustic Emissions in Children at School Entry: A Comparison with Pure-Tone Screening and Tympanometry Results. Lyons, April; Kei, Joseph; Driscoll, Carlie // Journal of the American Academy of Audiology;Nov/Dec2004, Vol. 15 Issue 10, p702 

    This study examined the test performance of distortion product otoacoustic emissions (DPOAEs) when used as a screening tool in the school setting. A total of 1003 children (mean age 6.2 years, SD = 0.4) were tested with puretone screening, tympanometry, and DPOAE assessment. Optimal DPOAE test...

  • Ocena możliwoÅ›ci wykorzystania emisji otoakustycznych w badaniach przesiewowych sÅ‚uchu u dzieci szkolnych w wieku 6-13 lat. Piłka, Edyta; Trzaskowski, Bartosz; Jędrzejczak, W. Wiktor; Kochanek, Krzysztof; Skarżyński, Henryk // Otorynolaryngologia;Mar2012, Vol. 11 Issue 1, p7 

    Introduction. Otoacoustic emissions are weak acoustic signals that can be measured in the ear canal. Their measurements enable obtaining information on the status of the cochlea in the inner ear. The most frequent application of otoacoustic emission is screening of newborns for hearing loss....

  • An Evaluation of the Cross-Check Principle Using Visual Reinforcement Audiometry, Otoacoustic Emissions, and Tympanometry. Baldwin, Stacey M.; Gajewski, Byron J.; Widen, Judith E. // Journal of the American Academy of Audiology;Mar2010, Vol. 21 Issue 3, p187 

    Background: Early intervention to reduce the effects of congenital hearing loss requires accurate description of hearing loss. In pediatric audiology, a cross-check principle is used to compare behavioral and physiological tests. Purpose: The purpose of this study was to investigate the...

  • Signal-to-Noise Ratios of the Auditory Steady-State Response from Fifty-Five EEG Derivations in Adults. van der Reijden, C. S.; Mens, Lucas H. M.; Snik, Ad F. M. // Journal of the American Academy of Audiology;Nov/Dec2004, Vol. 15 Issue 10, p692 

    The Auditory Steady-State Response (ASSR) was recorded in 20 awake adults with normal hearing on ten EEG channels simultaneously to find derivations with the best signal-to-noise ratios (SNRs). Stimuli were 20% frequency modulated tones of 0.5 and 2 kHz at 20 dB SL, 100% amplitude modulated at...

  • Adaptive Filter Based Two-Probe Noise Suppression System for Transient Evoked Otoacoustic Emission Detection. Subotić, Miško; Šarić, Zoran; Jovičić, Slobodan // Annals of Biomedical Engineering;Mar2012, Vol. 40 Issue 3, p637 

    Transient otoacoustic emission (TEOAE) is a method widely used in clinical practice for assessment of hearing quality. The main problem in TEOAE detection is its much lower level than the level of environmental and biological noise. While the environmental noise level can be controlled, the...

  • Time-Frequency Properties of Neonatal Transiently Evoked Otoacoustic Emissions Measured in Three Different Acquisition Modes. Jedrzejczak, W. Wiktor; Hatzopoulos, Stavros; Skarzynski, Piotr H.; Skarzynski, Henryk // Journal of International Advanced Otology;2014, Vol. 10 Issue 1, p52 

    OBJECTIVE: The purpose of this study was to investigate transiently evoked otoacoustic emissions recorded from the cochleas of neonates using three acquisition protocols: non-linear; linear; and QuickScreen. In the non-linear mode, a series of four clicks was used, with three clicks at the same...

  • TECHNICAL BRIEFS.  // Noise & Vibration Worldwide;Jun2015, Vol. 46 Issue 6, p29 

    The article offers technical news briefs. Topics include the effect of otoacoustic emissions amplitudes on the risk of leusure noise exposure on Asian youth, a global-scale statistics on sound propagation, and prediction on the accuracy of speech transmission based on signal-to-noise ratio and...

  • Olivocochlear efferent function: issues regarding methods and the interpretation of results. Guinan Jr., John J. // Frontiers in Systems Neuroscience;Aug2014, Vol. 8, p1 

    As studies of the olivocochlear (OC) efferent system have matured, issues have been identified that need to be taken into account in the design of new studies and in the interpretation of existing work. The need for high signal-to-noise ratios (SNRs), multiple alternations of conditions, and...

  • Improved measurement method for electron energy distribution functions with high accuracy and reliability. Jin Young Bang; Aram Kim; Chin Wook Chung // Physics of Plasmas;Jun2010, Vol. 17 Issue 6, p064502 

    An improved ac superimposed method for measuring the electron energy distribution function (EEDF) with high accuracy is proposed. Although high amplitude of the superimposed ac voltage provides a higher signal-to-noise ratio (SNR), it causes the distortion in the EEDF. To correct the distortion,...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics