TITLE

Korea superconducting tokamak advanced research vacuum and gas puffing system

AUTHOR(S)
Seo, Seong-Heon; Kim, H. T.; Kim, K. P.; Kim, Y. O.; Kim, W. C.; Yang, H. L.; Oh, Y. K.; Jeong, Seung Ho
PUB. DATE
November 2008
SOURCE
Review of Scientific Instruments;Nov2008, Vol. 79 Issue 11, p116103
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A piezoelectric valve, which has a flow rate of about 463 mbar l/s, has been installed to fuel the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. The valve flow rate is in situ calibrated by analyzing the pressure rise curve while fueling the vessel at a constant rate. The calibration method and results are presented. In addition to the flow rate, other vacuum system parameters, such as the pumping speed and the vessel volume, were experimentally obtained. Based on these measurements, a KSTAR vacuum system simulator was developed to calculate the valve drive signal to obtain a programmed pressure trace. An arbitrarily shaped pressure trace was successfully controlled in KSTAR with this hardware and software system.
ACCESSION #
35886460

 

Related Articles

  • Calibration and test of the tangential phase contrast imaging diagnostic on CDX-U. Lo, E.; Nazikian, R.; Stutman, D.; Choe, W.; Kaita, R. // Review of Scientific Instruments;Feb1997, Vol. 68 Issue 2, p1206 

    Focuses on the calibration of a carbon dioxide laser-based tangential imaging diagnostic system for used in measuring two-dimensional images of density fluctuations on CDU-X tokamak. Optical layout of the imaging system; Operation of the system at its maximum responsivity; Use of sound waves to...

  • Absolute calibration of the JT-60U neutron monitors using a 252Cf neutron sourcea). Nishitani, T.; Takeuchi, H.; Kondoh, T.; Itoh, T.; Kuriyama, M.; Ikeda, Y.; Iguchi, T.; Barnes, Cris W. // Review of Scientific Instruments;Nov92, Vol. 63 Issue 11, p5270 

    Absolutely calibrated measurements of the neutron yield are important for the evaluation of plasma performance such as the fusion gain Q in D–D operating tokamaks. The time-resolved neutron yield is measured with 235U and 238U fission chambers and 3He proportional counters in the JT-60U...

  • Calibration of the neutron yield measurement system on FTU tokamak (abstract). Angelone, M.; Batistoni, P.; Bertalot, L.; Esposito, B.; Martone, M.; Podda, S.; Pillon, M.; Rapisarda, M.; Rollet, S. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p3230 

    This paper describes the in situ calibration of the BF[sub 3] detector system used for measuring the total neutron yield from the FTU tokamak. Two different neutron sources, [sup 252]Cf (7.23 × 10[sup 7] n/s) and AmBe (2.18 × 10[sup 6] n/s), were used. The calibration was performed by...

  • Experimental and numerical calibration of the neutron activation system on the FTU tokamak. Angelone, M.; Batistoni, P.; Bertalot, L.; Esposito, B.; Martone, M.; Pillon, M.; Podda, S.; Rapisarda, M.; Rollet, S. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p3157 

    A benchmark experiment has been performed for the absolute calibration of the FTU tokamak neutron activation system with the purpose of comparing experimental and numerical absolute reaction rates. Indium samples have been activated by a [sup 252]Cf neutron source located on the torus axis at...

  • Development of a fast valve for mitigating disruptions in tokamaks. Savtchkov, A.; Finken, K. H.; Mank, G. // Review of Scientific Instruments;Oct2002, Vol. 73 Issue 10, p3490 

    In support of our disruption mitigation profram, a fast gas valve has been constructed and tested on TEXTOR at FZJ Juelich. Its main features have been shown to be: (1) rapid response time: 0.5 ms; (2) amount of injected gas: variable, 2-1000 mbar×1; (3) linear dependence of the number of...

  • Measurements of the neutron source strength at DIlI-D Heidbrink, W. W.; Taylor, P. L.; Phillips, J. A. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p536 

    Documents the calibration procedure for neutron counters and scintillators used to measure the neutron emission produced by the DIII-D tokamak. Detectors and calibration; Detector comparisons; Comparison with other diagnostics.

  • Neutron calibration techniques for comparison of tokamak results. Strachan, J. D.; Adams, J. M.; Barnes, Cris W.; Batistoni, P.; Bosch, H.-S.; Brzosko, J. S.; England, A. C.; Fiore, C. L.; Granetz, R. S.; Hendel, H. W.; Hoenen, F.; Jarvis, O. N.; Jassby, D. L.; Ku, L. P.; Liu, P.; Martin, G.; McCauley, S.; Motley, R. W.; Nishitani, T. // Review of Scientific Instruments;Nov90, Vol. 61 Issue 11, p3501 

    A workshop on 1–3 August 1989 reviewed the techniques, uncertainties, and experiences of neutron calibration on PLT, TFTR, JET, Tore Supra, JT-60, JIPPT-IIU, Alcator C-Mod, ATF, FT, ASDEX, Textor, and DIII-D. In the summary session, the workshop participants discussed possible consensus...

  • Neutron calibration techniques for comparison of tokamak results (abstract). Strachan, J. D.; Adams, J. M.; Barnes, Cris W.; Batistoni, P.; Bosch, H.-S.; Brzosko, J. S.; England, A. C.; Fiore, C. L.; Granetz, R. S.; Hendel, H. W.; Hoenen, F.; Jarvis, O. N.; Jassby, D. L.; Ku, L. P.; Liu, P.; Martin, G.; McCauley, S.; Motley, R. W.; Nishitani, T. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p3232 

    A workshop on 1-3 August 1989 reviewed the techniques, uncertainties, and experiences of neutron calibration on PLT, TFTR, JET, Tore Supra, JT-60, JIPPT-IIU, Alcator C-Mod, ATF, FT, ASDEX, Textor, and DIII-D. In the summary session, the workshop participants discussed possible consensus neutron...

  • Low dead volume piezoelectric valve. Marinescu, Dan // Review of Scientific Instruments;Jun90, Vol. 61 Issue 6, p1749 

    By using a capillary tube as both seat and exit duct in a commercial piezoelectric valve, the outlet dead volume is reduced by more than three orders of magnitude. The described modification also makes a separation between the gas flow and the actuator chamber which considerably extends the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.