TITLE

Selectivity for glucose, glucose-6-phosphate, and pyruvate in ternary mixtures from the multivariate analysis of near-infrared spectra

AUTHOR(S)
Liu, Lingzhi; Arnold, Mark A.
PUB. DATE
January 2009
SOURCE
Analytical & Bioanalytical Chemistry;Jan2009, Vol. 393 Issue 2, p669
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Near-infrared spectroscopy offers the potential for direct in situ analysis in complex biological systems. Chemical selectivity is a critical issue for such measurements given the extent of spectral overlap of overtone and combination spectra. In this work, the chemical basis of selectivity is investigated for a set of multivariate calibration models designed to quantify glucose, glucose-6-phosphate, and pyruvate independently in ternary mixtures. Near-infrared spectra are collected over the combination region (4,000–5,000 cm−1) for a set of 60 standard solutions maintained at 37 °C. These standard solutions are composed of randomized concentrations (0.5–30 mM) of glucose, glucose-6-phosphate, and pyruvate. Individual calibration models are constructed for each solute by using the partial least-squares (PLS) algorithm with optimized spectral range and number of latent variables. The resulting standard errors are 0.90, 0.72, and 0.32 mM for glucose, glucose-6-phosphate, and pyruvate, respectively. A pure component selectivity analysis (PCSA) demonstrates selectivity for each solute in these ternary samples. The concentration of each solute is also predicted for each sample by using a set of net analyte signal (NAS) calibration models. A comparison of the PLS and NAS calibration vectors demonstrates the chemical basis of selectivity for these multivariate methods. Selectivity of each PLS and NAS calibration model originates from the unique spectral features associated with the targeted analyte. Overall, selectivity is demonstrated for each solute with an order of sensitivity of pyruvate > glucose-6-phosphate > glucose. [Figure not available: see fulltext.]
ACCESSION #
35774251

 

Related Articles

  • Design and Synthesis of Near-infrared Fluorescent Probes for Imaging of Biological Nitroxyl. Tan, Yi; Liu, Ruochuan; Zhang, Huatang; Peltier, Raoul; Sun, Hongyan; Lam, Yun-Wah; Zhu, Qing; Hu, Yi // Scientific Reports;11/20/2015, p16979 

    Nitroxyl (HNO), the reduced and protonated form of nitric oxide (NO), has recently been identified as an interesting and important signaling molecule in biological systems. However, research on its biosynthesis and bioactivities are hampered by the lack of versatile HNO detection methods...

  • Terahertz near-field microscopy based on a collection mode detector. Mitrofanov, O.; Brener, I.; Harel, R.; Wynn, J. D.; Wynn, J.D.; Pfeiffer, L. N.; Pfeiffer, L.N.; West, K. W.; West, K.W.; Federici, J. // Applied Physics Letters;11/27/2000, Vol. 77 Issue 22 

    We report on the development of a collection mode near-field probe for the terahertz spectral range. The near-field detector is based on an aperture type probe with dimensions of 30x30 μm[sup 2]. The collection mode technique provides higher sensitivity and higher resolution than the similar...

  • Can near infrared spectroscopy of the liver monitor tissue oxygenation? Teller, Jan; Wolf, Martin; Keel, Mathias; Bucher, Hans-Ulrich; Fanconi, Sergio; Baenziger, Oskar; Teller, J; Wolf, M; Keel, M; Bucher, H U; Fanconi, S; Baenziger, O // European Journal of Pediatrics;2000, Vol. 159 Issue 7, p549 

    Measurement of the hepatic oxygenation index by near infrared spectroscopy is a suitable method to estimate the oxygenation and can be a non-invasive means to continuously monitor tissue perfusion and to detect early haemodynamic disturbances in critically ill children.

  • Market Profile: UV-vis-NIR microscopy.  // Spectroscopy;Jul2012, Vol. 27 Issue 7, p12 

    The article reports on the increase in the demand for microscopy-enabled ultraviolet (UV)-vis-near infrared (NIR) spectroscopy in the U.S.

  • Polymer analyzer performs multiple QC analyses at once.  // Plastics Technology;Jun96, Vol. 42 Issue 6, p12 

    Reports on the Fourier-transform near-infrared (FT-NIR) spectrometer which contains advanced software that can perform multiple nondestructive quality control analyses of plastics from a single measurement. Features; Benefits; Price.

  • Employing Near-Infrared Spectroscopic Methods of Analysis for Fermentation Monitoring and Control: Part 1, Method Development. Arnold, S. Alison; Harvey, Linda M.; McNeil, Brian; Hall, Jeffrey W. // BioPharm International;Nov2002, Vol. 15 Issue 11, p26 

    Part I. Focuses on the employment of near-infrared spectroscopic (NIR) methods of analysis for fermentation monitoring and control. Importance of process information about fermentation biomass, substrates, intermediates and nutrients in making control decisions; Way by which NIR spectroscopy...

  • Employing Near-Infrared Spectroscopic Methods of Analysis for Fermentation Monitoring and Control/ Part 2, Implementation Strategies. Arnold, S. Alison; Harvey, Linda M.; McNeil, Brian; Hall, Jeffrey W. // BioPharm International;Jan2003, Vol. 16 Issue 1, p47 

    Part II. Reports on the strategies for implementing near-infrared (NIR) spectroscopy methods of analysis for fermentation monitoring and control. Physical characteristics of the broth media; Requirements of process monitoring and control; Evaluation of the potential use of NIR spectroscopy for...

  • Estimation of wood stiffness of increment cores by near-infrared spectroscopy. Schimleck, L.R.; Evans, R.; Ilic, J.; Matheson, A.C. // Canadian Journal of Forest Research;Jan2002, Vol. 32 Issue 1, p129 

    Describes the use of calibrated near infrared spectroscopy to estimate the wood stiffness of increment cores. Importance of wood stiffness for solid timber applications; Calculation of the mean air-dry densities of the samples using wood masses and dimensions; Factor essential in the success of...

  • Resonant and nonresonant transmission through waveguide bends in a planar photonic crystal. Olivier, S.; Benisty, H.; Rattier, M.; Weisbuch, C.; Qiu, M.; Karlsson, A.; Smith, C. J. M.; Houdre´, R.; Oesterle, U. // Applied Physics Letters;10/15/2001, Vol. 79 Issue 16, p2514 

    We have measured the near-infrared transmission spectra of 60° bends defined in two-dimensional photonic crystal waveguides consisting of three missing rows. Two limit cases are studied: a basic nonresonant bend and a bend built around a resonant lozenge cavity, which is found to exhibit...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics