TITLE

Cholera toxin subunit B detection in microfluidic devices

AUTHOR(S)
Bunyakul, Natinan; Edwards, Katie; Promptmas, Chamras; Baeumner, Antje
PUB. DATE
January 2009
SOURCE
Analytical & Bioanalytical Chemistry;Jan2009, Vol. 393 Issue 1, p177
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Fluorescence and electrochemical microfluidic biosensors were developed for the detection of cholera toxin subunit B (CTB) as a model analyte. The microfluidic devices were made from polydimethylsiloxane (PDMS) using soft lithography from silicon templates. The polymer channels were sealed with a glass plate and packaged in a polymethylmethacrylate housing that provided leakproof sealing and a connection to a syringe pump. In the electrochemical format, an interdigitated ultramicroelectrode array (IDUA) was patterned onto the glass slide using photolithography, gold evaporation and lift-off processes. For CTB recognition, CTB-specific antibodies were immobilized onto superparamagnetic beads and ganglioside GM1 was incorporated into liposomes. The fluorescence dye sulforhodamine B (SRB) and the electroactive compounds potassium hexacyanoferrate (II)/hexacyanoferrate (III) were used as detection markers that were encapsulated inside the liposomes for the fluorescence and electrochemical detection formats, respectively. Initial optimization experiments were carried out by applying the superparamagnetic beads in microtiter plate assays and SRB liposomes before they were transferred to the microfluidic systems. The limits of detection (LoD) of both assay formats for CTB were found to be 6.6 and 1.0 ng mL−1 for the fluorescence and electrochemical formats, respectively. Changing the detection system was very easy, requiring only the synthesis of different marker-encapsulating liposomes, as well as the exchange of the detection unit. It was found that, in addition to a lower LoD, the electrochemical format assay showed advantages over the fluorescence format in terms of flexibility and reliability of signal recording.
ACCESSION #
35757071

 

Related Articles

  • Microfluidic biosensor for cholera toxin detection in fecal samples. Bunyakul, Natinan; Promptmas, Chamras; Baeumner, Antje // Analytical & Bioanalytical Chemistry;Jan2015, Vol. 407 Issue 3, p727 

    Sample preparation and processing steps are the most critical assay aspects that require our attention in the development of diagnostic devices for analytes present in complex matrices. In the best scenarios, diagnostic devices should use only simple sample processing. We have therefore...

  • Detection of Explosives in a Dynamic Marine Environment Using a Moored TNT Immunosensor. Charles, Paul T.; Adams, André A.; Deschamps, Jeffrey R.; Veitch, Scott; Hanson, Al; Kusterbeck, Anne W. // Sensors (14248220);Mar2014, Vol. 14 Issue 3, p4074 

    A field demonstration and longevity assessment for long-term monitoring of the explosive 2,4,6-trinitrotoluene (TNT) in a marine environment using an anti-TNT microfluidic immunosensor is described. The TNT immunosensor is comprised of a microfluidic device with 39 parallel microchannels (2.5 cm...

  • Fluorescence-based Sensing of 2,4,6-Trinitrotoluene (TNT) Using a Multi-channeled Poly(methyl methacrylate) (PMMA) Microimmunosensor. Charles, Paul T.; Adams, Andre A.; Howell Jr., Peter B.; Trammell, Scott A.; Deschamps, Jeffrey R.; Kusterbeck, Anne W. // Sensors (14248220);2010, Vol. 10 Issue 1, p876 

    Fluorescence immunoassays employing monoclonal antibodies directed against the explosive 2,4,6-trinitrotoluene (TNT) were conducted in a multi-channel microimmunosensor. The multi-channel microimmunosensor was prepared in poly (methyl methacrylate) (PMMA) via hot embossing from a brass molding...

  • Transcutaneous Immunization Studies in Mice Using Diphtheria Toxoid-Loaded Vesicle Formulations and a Microneedle Array. Ding, Zhi; Bal, Suzanne; Romeijn, Stefan; Kersten, Gideon; Jiskoot, Wim; Bouwstra, Joke // Pharmaceutical Research;Jan2011, Vol. 28 Issue 1, p145 

    Purpose: To determine the immunogenicity of diphtheria toxoid (DT) formulated in two types of vesicles following transcutaneous immunization (TCI) of mice onto microneedle array-treated skin. Methods: DT-containing cationic liposomes or anionic surfactant-based vesicles were prepared by...

  • Design and construction of a micromilled fluidic device as part of a DNA biosensor. Townsend, R. J.; Harris, N. R.; Wenn, D.; Brennan, D.; Grabham, N. J. // Proceedings of the Institution of Mechanical Engineers -- Part C;May2008, Vol. 222 Issue 5, p847 

    Under the Optonanogen project (EU contract IST-2001-37239), a novel biosensor has been developed, which incorporates a disposable acrylic polymethylmethacrylate (PMMA) fluidic header. This header is designed to deliver a sample to a series of chemically primed cantilevers where hybridization of...

  • Application of Liposome Based Sensors in High-Throughput Screening Systems. Przybylo, Magda; Borowik, Tomasz; Langner, Marek // Combinatorial Chemistry & High Throughput Screening;Jul2007, Vol. 10 Issue 6, p441 

    High throughout screening is an approach based on the concept which assumes that when sufficiently large library of compounds are tested, the chance of discovering a new active compound is increased. In order to meet this expectation, proper testing criteria need to be devised. Those criteria...

  • Biosensing with Paper-Based Miniaturized Printed Electrodes-A Modern Trend. Silveira, Célia M.; Monteiro, Tiago; Almeida, Maria Gabriela // Biosensors (2079-6374);Dec2016, Vol. 6 Issue 4, p1 

    From the bench-mark work on microfluidics from the Whitesides's group in 2007, paper technology has experienced significant growth, particularly regarding applications in biomedical research and clinical diagnostics. Besides the structural properties supporting microfluidics, other advantageous...

  • Picoliter droplet microfluidic immunosorbent platform for point-of-care diagnostics of tetanus. Golberg, Alexander; Yarmush, Martin; Konry, Tania // Microchimica Acta;Jul2013, Vol. 180 Issue 9/10, p855 

    We have developed a sensitive, specific, rapid and low cost picoliter microsphere-based platform for bioanalyte detection and quantification. In this method, a biological sample, biosensing microspheres, and fluorescently labeled detection (secondary) antibodies are co-encapsulated to capture...

  • Recent Developments in Optical Detection Technologies in Lab-on-a-Chip Devices for Biosensing Applications. Matos Pires, Nuno Miguel; Tao Dong; Hanke, Ulrik; Hoivik, Nils // Sensors (14248220);Aug2014, Vol. 14 Issue 8, p15458 

    The field of microfluidics has yet to develop practical devices that provide real clinical value. One of the main reasons for this is the difficulty in realizing low-cost, sensitive, reproducible, and portable analyte detection microfluidic systems. Previous research has addressed two main...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics