TITLE

Optimization of Energy Conservation Potential for VAV Air Conditioning System using Fuzzy based Genetic Algorithm

AUTHOR(S)
Parameshwaran, R.; Karunakaran, R.; Iniyan, S.; Samuel, Anand A.
PUB. DATE
October 2008
SOURCE
International Journal of Mathematical, Physical, & Engineering S;2008, Vol. 2 Issue 4, p223
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The objective of this study is to present the test results of variable air volume (VAV) air conditioning system optimized by two objective genetic algorithm (GA). The objective functions are energy savings and thermal comfort. The optimal set points for fuzzy logic controller (FLC) are the supply air temperature (Ts), the supply duct static pressure (Ps), the chilled water temperature (Tw), and zone temperature (Tz) that is taken as the problem variables. Supply airflow rate and chilled water flow rate are considered to be the constraints. The optimal set point values are obtained from GA process and assigned into fuzzy logic controller (FLC) in order to conserve energy and maintain thermal comfort in real time VAV air conditioning system. A VAV air conditioning system with FLC installed in a software laboratory has been taken for the purpose of energy analysis. The total energy saving obtained in VAV GA optimization system with FLC compared with constant air volume (CAV) system is expected to achieve 31.5%. The optimal duct static pressure obtained through Genetic fuzzy methodology attributes to better air distribution by delivering the optimal quantity of supply air to the conditioned space. This combination enhanced the advantages of uniform air distribution, thermal comfort and improved energy savings potential.
ACCESSION #
35619455

 

Related Articles

  • Design Guide Outlines Efficient Ventilation.  // Design News;10/7/91, Vol. 47 Issue 19, p17 

    Reports on the compilation of a design guide for engineers who use variable air volume as the air-delivery system in buildings in the U.S. Role of the system in saving energy; Ability of the system to deliver the right amount of air; Testing of the systems in several buildings.

  • Detecting Faults In Hong Kong High-Rise. YOUMING CHEN; HAITAO WANG; CHAN, CARY W. H.; JIANYING QIN // ASHRAE Journal;Jan2014, Vol. 56 Issue 1, p46 

    The article focuses on the installation of a fault detection system with nearly 1,200 variable air volume systems (VAV) at Cambridge House building in Hong Kong, China. It explores the use of fault detection and diagnosis (FDD) in VAV terminals, saying that FDD can improve the thermal comfort,...

  • System Differences.  // Heating/Piping/Air Conditioning Engineering;Aug2009, Vol. 81 Issue 8, p20 

    The article focuses on the American Society of Heating, Refrigerating, and Air-Conditioning Engineers "single-duct" variable-air-volume (VAV) system as an illustration of the system differences where it is the most often encountered form of VAV. It states that it comprises a single air handling...

  • Energy Performances of Prototype VAV and CAV Systems under Simulated Humid Tropical Climates. Ameen, Ahmadul; Mahmud, Khizir // ASHRAE Transactions;2005, Vol. 111 Issue 1, p320 

    This paper reports the relative energy consumption of prototype VAV and CAV air-conditioning systems under various load conditions simulating those of a typical office building in humid tropical climates such as Singapore's. Tests were conducted inside two adjoining environmental chambers where...

  • Experimental Study of Lab Controlled Faults in Dual-Duct VAV System. Ran Liu; Xiaohui Zhou; Milbrandt, Robert; Lochhead, Scott // ASHRAE Transactions;2015, Vol. 121 Issue 2, p1 

    No abstract available.

  • BE CAREFUL What You Ask For. Audin, Lindsay // Engineered Systems;Jan2004, Vol. 21 Issue 1, p42 

    Focuses on the impact of energy cost cutting in buildings on the heating and ventilation industry (HVAC). Link between lighting and HVAC; Result on the reduction in lighting wattage; Need to raise the minimum variable air volume systems flow rate.

  • Energy Modeling. Nelson, Kirby // ASHRAE Journal;Sep2014, Vol. 56 Issue 9, p10 

    A letter to the editor is presented in response to a letter writer in the July 2014 "Letters" about the article "VAV vs. Radiant" on energy modeling in the May issue.

  • Effect of room modelling and sensor position on performance assessment of variable air volume control systems. Riederer, P; Dexter, AL // Building Services Engineering Research & Technology;Feb2003, Vol. 24 Issue 1, p9 

    Variable air volume (VAV) systems are commonly used for air conditioning in buildings. The testing of different control strategies and controllers for this application has been a main concern in several simulation studies. In these simulations much attention has been paid to the accuracy of the...

  • VAV Boxes. Stein, Jeff // Occupational Hazards;Nov2005, Vol. 67 Issue 11, p40 

    Discusses the important zone-level and controls decisions a specifying engineer must take regarding variable-air-volume boxes to achieve a system that is both energy efficient and that provides thermal comfort. Use of cooling-only boxes; Sizes of box that can be chosen; Basic steps of box sizing.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics