TITLE

System Configurations

PUB. DATE
December 2008
SOURCE
Heating/Piping/Air Conditioning Engineering;Dec2008, Vol. 80 Issue 12, p19
SOURCE TYPE
Periodical
DOC. TYPE
Article
ABSTRACT
The article discusses the configuration management for thermal-energy transfer (TET) system in the U.S. These TET system configurations factors include vertical stack, consule, water-to-water and roof-top water-to-air. Information about the brief description, usefulness and its contribution towards green commercial building is included.
ACCESSION #
35598688

 

Related Articles

  • Dont Do It for Al Gore; Do It Because It's Good for Business! Rawson, Randy // Heating/Piping/Air Conditioning Engineering;Jan2008, Vol. 80 Issue 1, pBSE3 

    The author reflects on going green for commercial, institutional, and industrial boiler owners. He says that while companies wait for guidance from lawmakers and regulators, fuel and money are wasted while the cost energy increases. He argues that the decision to go green should come as the...

  • The optimization ratio study of steady state heat transfer and dynamic heat transfer in Hot-humid and Cold-humid Area. Shuang Liang; Wang Yan // Advanced Materials Research;2014, Issue 935, p52 

    By means of the establishment of thermal stability evaluation model and simulating in Huafeng factory residential building, the relationship between the D value and building thermal stability and the optimal distribution ratio are obtained. The results show that:at the shape coefficient=0.40,...

  • Heat transfer characteristics in latent heat storage system using paraffin wax. Jesumathy, Stella; Udayakumar, M.; Suresh, S. // Journal of Mechanical Science & Technology;Mar2012, Vol. 26 Issue 3, p959 

    An energy storage system has been designed to study the heat transfer characteristics of paraffin wax during melting and solidification processes in a vertical annulus energy storage system. In the experimental study, three important issues are focused. The first one is temperature distribution...

  • PHASE CHANGE MATERIAL AS A THERMAL ENERGY STORAGE MATERIAL FOR COOLING OF BUILDING. Ravikumar, M.; Srinivasan, Pss. // Journal of Theoretical & Applied Information Technology;6/1/2008, Vol. 4 Issue 6, p503 

    As the demand for refrigeration and Air conditioning has been increased during the last decade, the cool storage systems can be used to the economic advantage over conventional cooling plants. Cool storage system using phase change materials can be used for peak load shifting if they are...

  • TECHNOLOGY OF GRAVITY COOLING AND HEAT TRANSFER SYSTEMS. McIntosh, G. E. // AIP Conference Proceedings;4/9/2010, Vol. 1218 Issue 1, p1541 

    Dewar pressure build-up coils, thermosiphon cooling systems and closed loop thermosiphons are simple and effective tools when properly designed and fabricated. However, out of ignorance or misplaced economy, some of these systems work poorly or not at all. This paper reviews the fundamentals of...

  • Entransy and its Utilization in Problems of Thermodynamics and Heat Transfer. Oliveira, Santiago del Rio; Milanez, Luiz Fernando // International Review of Mechanical Engineering;Mar2012, Vol. 6 Issue 3, p420 

    The concept of entransy was recently proposed in terms of the analogy to the electric energy stored in a capacitor. The entransy of a system describes its heat transfer ability, as the exergy of a system quantifies its work production potential. Hence, the concept of entransy can be useful in...

  • CHAPTER 44: AIR-TO-AIR ENERGY RECOVERY.  // ASHRAE Handbook: Heating, Ventilating & Air-Conditioning Systems;2004, p44.1 

    Chapter 44 of the book "2004 ASHRAE Handbook: Heating, Ventilating and Air-Conditioning Systems and Equipment" is presented. It gives an account of various technologies for air-to-air energy recovery. It also points out the thermal and economic performance, maintenance and related operational...

  • The Effect of Fouling on Low Temperature Heat Exchangers Performance Based on Exergy Analysis. Shuang-Ying Wu; Xiao-Feng Yuan; You-Rong Li // Journal of Superconductivity & Novel Magnetism;Aug2010, Vol. 23 Issue 6, p1119 

    By analyzing heat and exergy transfer processes of heat exchangers operating below the surrounding temperature, the effect of fouling on the low temperature heat exchangers performance has been conducted. Taking the parallel flow, counter flow, and cross flow low temperature heat exchangers as...

  • Heat flow in proteins: Computation of thermal transport coefficients. Yu, Xin; Leitner, David M. // Journal of Chemical Physics;2/1/2005, Vol. 122 Issue 5, p054902 

    The rate of vibrational energy transfer and thermal transport coefficients are computed for two structurally distinct proteins, green fluorescent protein (GFP) and myoglobin. The computation of thermal transport coefficients exploits the scaling of the energy diffusion coefficient with the...