ABSTRACT
Background: Arthritic changes to glenoid morphology can be difficult to fully characterize on both plain radiographs and conventional two-dimensional computer tomography images. We tested the hypothesis that three-dimensional imaging of the shoulder would increase inter-rater agreement for assessing the extent and location of glenoid bone loss and also would improve surgical planning for total shoulder arthroplasty. Methods: Four shoulder surgeons independently and retrospectively reviewed the preoperative computed tomography scans of twenty-four arthritic shoulders. The blinded images were evaluated with conventional two-dimensional imaging software and then later with novel three-dimensional imaging software. Measurements and preoperative judgments were made for each shoulder with use of each imaging modality and then were compared. The glenoid measurements were glenoid version and bone loss. The judgments were the zone of maximum glenoid bone loss, glenoid implant fit within the glenoid vault, and how to surgically address abnormal glenoid version and bone loss. Agreement between observers was evaluated with use of intraclass correlation coefficients and the weighted kappa coefficient (K), and we determined if surgical decisions changed with use of the three-dimensional data. Results: The average glenoid version (and standard deviation) measured - 17° ± 2.2° on the two-dimensional images and -19° ± 2.4° on the three-dimensional images (p < 0.05). The average posterior glenoid bone loss measured 9 ± 2.3 mm on the two-dimensional images and 7 ± 2 mm on the three-dimensional images (p < 0.05). The average anterior bone loss measured 1 mm on both the two-dimensional and the three-dimensional images. However, the intraclass correlation coefficients for anterior bone loss increased significantly with use of the three-dimensional data (from 0.36 to 0.70; p < 0.05). Observers were more likely to locate mid-anterior glenoid bone loss on the basis of the three-dimensional data (p < 0.05). The use of three-dimensional data provided greater agreement among observers with regard to the zone of glenoid bone loss, glenoid prosthetic fit, and surgical decision-making. Also, when the judgment of implant fit changed, observers more often determined that it would violate the vault walls on the basis of the three-dimensional data (p < 0.05). Conclusions: The use of three-dimensional imaging can increase inter-rater agreement for the analysis of glenoid morphology and preoperative planning. Important considerations such as the extent and location of glenoid bone loss and the likelihood of implant fit were influenced by the three-dimensional data. Clinical Relevance: We believe that these data support the concept that three-dimensional imaging techniques applied to the shoulder provide further information that may be useful to the surgeon during the planning of total shoulder arthroplasty.
ACCESSION #
35282019

 

Related Articles

  • Relationship of Bicipital Groove Rotation with Humeral Head Retroversion. Johnson, Jeff W.; Thostenson, Jeff D.; Suva, Larry J.; Ashfaq Hasan, S. // Journal of Bone & Joint Surgery, American Volume;4/17/2013, Vol. 95-A Issue 8, p719 

    Background: Bicipital groove location has been used as a reference for humeral stem orientation in total shoulder arthroplasty to recreate humeral head retroversion. However, anatomic variability has rendered its use for prosthetic orientation problematic in cases of comminuted proximal...

  • Determinants of Femoral Tunnel Length in Anterior Cruciate Ligament Reconstruction: CT Analysis of the Influence of Tunnel Orientation on the Length. Iyyampillai, Geethan; Thirunellai Raman, Easwar; Vaithyalingam Rajan, David; Krishnamoorthy, Ajith; Sahanand, Santhosh // Knee Surgery & Related Research;Dec2013, Vol. 25 Issue 4, p207 

    Purpose: The purpose of the study was to identify the femoral tunnel orientation that consistently results in a tunnel length of more than 35 mm in anterior cruciate ligament reconstruction. Materials and Methods: Computed tomography (CT) scans were obtained from 30 patients who did not have any...

  • Can an extracorporeal glenoid aiming device be used to optimize the position of the glenoid component in total shoulder arthroplasty? Verstraeten, Tom R. G. M.; Berghs, Bart; Van Tongel, Alexander; Volders, David; De Wilde, Lieven F. // International Journal of Shoulder Surgery;Oct-Dec2015, Vol. 9 Issue 4, p114 

    Purpose: Successful total shoulder arthroplasty (TSA) requires a correct position of the glenoid component. This study compares the accuracy of the positioning with a new developed glenoid aiming device and virtual three-dimensional computed tomography (3D-CT) scan positioning. Materials and...

  • Three-dimensional computed tomographic scanning. Banerjee, Arpan K.; Higgins, N. // Journal of the Royal Society of Medicine;Oct1990, Vol. 83 Issue 10, p607 

    The article discusses how three dimensional (3D) images produced by improved technology of computed tomography (CT) helped to diagnose and treat diseases. New models of CT scanners produce 3D image without using any extra hardware. Use of new software in three dimensional CT scanning helps to...

  • Analysis of three-dimensional photoacoustic imaging of a vascular tree in vitro. Pilatou, Magdalena C.; Voogd, Nico J.; de Mul, Frits F.M.; Steenbergen, Wiendelt; Adrichem, Leon N.A. // Review of Scientific Instruments;Oct2003, Vol. 74 Issue 10, p4495 

    We used photoacoustics in order to image a vasculature cast, which was obtained from a Wistar rat. The main objective was to investigate the imaging quality and the performance of the beamforming algorithm. For these purposes, the specimen was measured in several Intralipidâ„¢ 10% solutions...

  • Comparative evaluation of scatter correction techniques in 3D positron emission tomography. Zaidi, Habib // European Journal of Nuclear Medicine;2000, Vol. 27 Issue 12, p1813 

    Provides information on a study which examined the use of Monte Carlo simulations, experimental measurements and clinical studies to characterize scatter correction algorithms in three dimensional positron emission tomography. Materials and methods used in the study; Results and discussion.

  • Quantitative 3D-CT Anatomy of Hamate Osteoarticular Autograft for Reconstruction of the Middle Phalanx Base. Berg, Paul; Ring, David // Clinical Orthopaedics & Related Research;Dec2012, Vol. 470 Issue 12, p3492 

    Background: Hamate osteoarticular autografts are difficult to obtain and it is unclear to what degree the graft matches the joint surface to be replaced and whether a direct ulnar approach might provide a more reliable graft than the standard proximal to distal approach. Purpose: We modeled...

  • CT scan evaluation of glenoid component fixation: a prospective study of 27 minimally cemented shoulder arthroplasties. Vidil, A.; Valenti, Ph.; Guichoux, F.; Barthas, J. // European Journal of Orthopaedic Surgery & Traumatology;Jul2013, Vol. 23 Issue 5, p521 

    Background: Glenoid component failure is the most common complication of total shoulder arthroplasty. It can be correlated with failure of the component itself to resist wear and deformation, failure of fixation or failure of the glenoid bone. Anchor Peg Glenoid component (Depuy) seems to have a...

  • Duocentric reversed shoulder prosthesis and Personal Fit templates: innovative strategies to optimize prosthesis positioning and prevent scapular notching. Trouilloud, P.; Gonzalvez, M.; Martz, P.; Charles, H.; Handelberg, F.; Nyffeler, R.; Baulot, E. // European Journal of Orthopaedic Surgery & Traumatology;May2014, Vol. 24 Issue 4, p483 

    We describe our experience with a new system of patient-specific template called Personal Fit, which is unique in shoulder surgery and used in combination with Duocentric prosthesis. The reverse prosthesis's concept is the invention of Paul Grammont, developed with Grammont's team of Dijon...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics