TITLE

Generation and dose distribution measurement of flash x-ray in KALI-5000 system

AUTHOR(S)
Menon, Rakhee; Roy, Amitava; Mitra, S.; Sharma, A.; Mondal, J.; Mittal, K. C.; Nagesh, K. V.; Chakravarthy, D. P.
PUB. DATE
October 2008
SOURCE
Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p103301
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Flash x-ray generation studies have been carried out in KALI-5000 Pulse power system. The intense relativistic electron beam has been bombarded on a tantalum target at anode to produce flash x-ray via bremsstrahlung conversion. The typical electron beam parameter was 360 kV, 18 kA, and 100 ns, with a few hundreds of A/cm2 current density. The x-ray dose has been measured with calcium sulfate:dysposium (CaSO4:Dy) thermoluminescent dosimeter and the axial dose distribution has been characterized. It has been observed that the on axis dose falls of with distance ∼1/xn, where n varies from 1.8 to 1.85. A maximum on axis dose of 46 mrad has been measured at 1 m distance from the source. A plastic scintillator with optical fiber coupled to a photomultiplier tube has been developed to measure the x-ray pulse width. The typical x-ray pulse width varied from 50 to 80 ns.
ACCESSION #
35150272

 

Related Articles

  • Monte Carlo simulation of x-ray emission by kilovolt electron bombardment. Acosta, E.; Llovet, X.; Coleoni, E.; Riveros, J.A.; Salvat, F. // Journal of Applied Physics;6/1/1998 Part 1 of 2, Vol. 83 Issue 11, p6038 

    Reports on a study which described a theoretical model used in the simulation of the x-ray spectra, with reference to the kilovolt electron beams. In-depth look at the inner shell ionization; Proposition of a double differential cross section for the bremsstrahlung emission; Methodology used to...

  • Spectral softening through Compton scattering. Pereira, N. R. // Journal of Applied Physics;3/1/1985, Vol. 57 Issue 5, p1445 

    Features a study that obtained flash bremsstrahlung from multi-megaelectronvolt electron beams by Compton backscatter from a material with low photoelectric absorption. Use of an x-ray transport code; Conversion efficiency between electric-beam energy and x-ray fluence from the converter with...

  • Bremsstrahlung target optimization for reflex triodes. Swanekamp, S. B.; Weber, B. V.; Stephanakis, S. J.; Mosher, D.; Commisso, R. J. // Physics of Plasmas;Aug2008, Vol. 15 Issue 8, p083105 

    The anode (tantalum) foil thickness in a reflex triode was varied from 2.5 to 250 μm to maximize the dose from bremsstrahlung produced by a 1 MV, 1 MA, 100 ns electron beam. Experiments and computer simulations show that the dose is maximized for a foil thickness of about 25 μm, 1/18th of...

  • Spatiotemporal behavior of X-ray emission above 20 keV from a Z-pinch produced by wire-array implosion. Aleksandrov, V. V.; Grabovski, E. V.; Gribov, A. N.; Gritsuk, A. N.; Medovshchikov, S. F.; Mitrofanov, K. N; Oleinik, G. M. // Plasma Physics Reports;Feb2009, Vol. 35 Issue 2, p136 

    Results are presented from experimental studies of hard X-ray (HXR) emission in the photon energy range above 20 keV from dense radiating Z-pinch plasmas. The work is aimed at revealing the nature of fast-electron (electron beam) generation during the implosion of cylindrical and conical wire...

  • Transport of a relativistic electron beam in gas and plasma-filled focusing cells for x-ray radiography. Welch, D. R.; Rose, D. V.; Oliver, B. V.; Schamiloglu, E.; Hahn, K.; Maenchen, J. E. // Physics of Plasmas;Feb2004, Vol. 11 Issue 2, p751 

    Gas cells have been used in radiographic sources to assist in the focusing of intense electron beams, produced using pulsed-power accelerators, onto a high atomic number target to generate bremsstrahlung radiation. The quality of the resulting source increases linearly with the dose and...

  • Monte Carlo Simulation of the Conversion X-Rays from the Electron Beam of PFMA-3. Ceccolini, E.; Rocchi, F.; Mostacci, D.; Sumini, M.; Tartari, A. // AIP Conference Proceedings;12/13/2011, Vol. 1412 Issue 1, p79 

    PFMA-3, a dense Plasma Focus device, is being optimized as an X-ray generator. X-rays are obtained from the conversion of the electron beam emitted in the backward direction and driven to impinge on a 50 μm brass foil. Monte Carlo simulations of the X-ray emission have been conducted with...

  • Quasi-monochromatic field-emission x-ray source. Diop, Babacar; Binh, Vu Thien // Review of Scientific Instruments;Sep2012, Vol. 83 Issue 9, p094704 

    By favoring the L-peak emission over the bremsstrahlung part, direct quasi-monochromatic soft x-ray emission has been obtained with a field emission (FE) x-ray source. The electron impact x-ray setup uses an arrayed cathode of carbon nanopearl FE tips as a stable cold electron source within a...

  • An extra-bright X-ray source. Zakharov, O. // Instruments & Experimental Techniques;Nov2010, Vol. 53 Issue 6, p866 

    bremsstrahlung X-ray source based on deceleration of electrons in the target is described. Its overall dimensions and cost are typical of bremsstrahlung sources, and the main parameters of its X-ray beam are similar to those of synchrotron sources. In a range of Δλ/λ = 10, the spectral...

  • The use and characterization of a backilluminated charge-coupled device in investigations of pulsed x-ray and radiation sources. Fullagar, Wilfred; Uhlig, Jens; Walczak, Monika; Canton, Sophie; Sundström, Villy // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p103302 

    Examinations of bremsstrahlung and energetic electron beams from a novel laser plasma source motivate and assist characterization of a backthinned, backilluminated direct detection x-ray charge-coupled device (CCD), a topology that is uncommon in hard x-ray work. Behavior toward...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics