TITLE

OZSPEC-2: An improved broadband high-resolution elliptical crystal x-ray spectrometer for high-energy density physics experiments (invited)

AUTHOR(S)
Heeter, R. F.; Anderson, S. G.; Booth, R.; Brown, G. V.; Emig, J.; Fulkerson, S.; McCarville, T.; Norman, D.; Schneider, M. B.; Young, B. K. F.
PUB. DATE
October 2008
SOURCE
Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E303
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A novel time, space, and energy-resolved x-ray spectrometer has been developed which produces, in a single snapshot, a broadband and relatively calibrated spectrum of the x-ray emission from a high-energy density laboratory plasma. The opacity zipper spectrometer (OZSPEC-1) records a nearly continuous spectrum for x-ray energies from 240 to 5800 eV in a single shot. The second-generation OZSPEC-2, detailed in this work, records fully continuous spectra on a single shot from any two of these three bands: 270–650, 660–1580, and 1960–4720 eV. These instruments thus record thermal and line radiation from a wide range of plasmas. These instruments’ single-shot bandwidth is unmatched in a time-gated spectrometer; conversely, other broadband instruments are either time-integrated (using crystals or gratings), lack spectral resolution (diode arrays), or cover a lower energy band (gratings). The OZSPECs are based on the zipper detector, a large-format (100×35 mm) gated microchannel plate detector, with spectra dispersed along the 100 mm dimension. OZSPEC-1 and -2 both use elliptically bent crystals of OHM, RAP, and/or PET. Individual spectra are gated in 100 ps. OZSPEC-2 provides one-dimensional spatial imaging with 30–50 μm resolution over a 1500 μm field of view at the source. The elliptical crystal design yields broad spectral coverage with resolution E/ΔE>500, strong rejection of hard x-ray backgrounds, and negligible source broadening for extended sources. Near-term applications include plasma opacity measurements, detailed spectra of inertial fusion Hohlraums, and laboratory astrophysics experiments.
ACCESSION #
35150252

 

Related Articles

  • MIAWARA-C, a new ground based water vapor radiometer for measurement campaigns. Straub, C.; Murk, A.; Kämpfer, N. // Atmospheric Measurement Techniques;2010, Vol. 3 Issue 5, p1271 

    The article presents a new ground based water vapor radiometer for measuring campaigns of the middle atmosphere. It notes on the optical system MIAWARA-C, which combines a very compact system designed with a type of correlation receiver that used a digital high resolution spectrometer. Thus, the...

  • Design and performance of a curved-crystal x-ray emission spectrometer. Hudson, A. C.; Stolte, W. C.; Lindle, D. W.; Guillemin, R. // Review of Scientific Instruments;May2007, Vol. 78 Issue 5, p053101 

    A curved-crystal x-ray emission spectrometer has been designed and built to measure 2–5 keV x-ray fluorescence resulting from a core-level excitation of gas phase species. The spectrometer can rotate 180°, allowing detection of emitted x rays with variable polarization angles, and is...

  • Elementary Ion Optics with Applications to Electromagnetic Spectrometers. Davids, B. // AIP Conference Proceedings;3/2/2010, Vol. 1213 Issue 1, p64 

    This lecture, intended for physics graduate students, represents an introduction to ion optics with applications to the electromagnetic spectrometers used in nuclear astrophysics research. A particular radiative capture reaction is chosen to illustrate the requirements of such spectrometers.

  • Very Low Energy Protons From the Beta Decay of Proton Rich Nuclei For Nuclear Astrophysics. Simmons, E.; Trache, L.; Banu, A.; McCleskey, M.; Roeder, B.; Spiridon, A.; Tribble, R. E.; Saastamoinen, A.; Aysto, J.; Davinson, T.; Woods, P. J.; Lotay, G. J. // AIP Conference Proceedings;3/2/2010, Vol. 1213 Issue 1, p239 

    We have developed a new experimental technique to measure very low energy protons from β-delayed p-decay of proton-rich nuclei produced and separated with the MARS recoil spectrometer at TAMU. Recently we have investigated the β-delayed p-decays of 23Al[1] and 31Cl[2] and obtained...

  • Precision Experiments with Stored and Cooled Ions. Schuch, Reinhold // AIP Conference Proceedings;2005, Vol. 748 Issue 1, p29 

    In this article I review some of the advances that were made with cooled trapped and stored highly charged ions. SMILETRAP at Stockholm University is a mass spectrometer with extreme precision that allows measuring ion masses to 10-10 accuracy. The SMILETRAP concept rests on the fact that the...

  • Imaging spectrometer for ultraviolet-near-infrared microspectroscopy. Johansson, Thomas; Pettersson, Anders // Review of Scientific Instruments;May97, Vol. 68 Issue 5, p1962 

    Describes the design and performance of a high speed imaging spectrometer system developed for the spectral analysis of micrometer-sized features in transmitted light. Instrument design; Measurement principle; Utilization of the wavelength range from ultraviolet to near infrared; Two white...

  • Products.  // Spectroscopy;Jan2000, Vol. 15 Issue 1, p44 

    Evaluates several instruments used in spectrometry research. Features of the Analect Reflect IR system from Orbital Sciences; Components of the 932 Plus double-beam atomic absorption spectrometer from GBC Scientific; Features of the third generation ultra-violet laser ablation system for solids...

  • Infrared Spectrometers. Livingstone, Paul // R&D Magazine;Apr2010, Vol. 52 Issue 2, p15 

    The articles presents a specifications guide for infrared spectrometers.

  • UV-Vis Spectrometers. Hock, Lindsay // R&D Magazine;Apr2010, Vol. 52 Issue 2, p16 