TITLE

Performance of the EBIT calorimeter spectrometer

AUTHOR(S)
Porter, Frederick Scott; Gygax, John; Kelley, Richard L.; Kilbourne, Caroline A.; King, Jonathan M.; Beiersdorfer, Peter; Brown, Gregory V.; Thorn, Daniel B.; Kahn, Steven M.
PUB. DATE
October 2008
SOURCE
Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E307
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The EBIT calorimeter spectrometer (ECS) is a new high-resolution, broadband x-ray spectrometer that has recently been installed at the Electron Beam Ion Trap Facility (EBIT) at the Lawrence Livermore National Laboratory. The ECS is an entirely new production class spectrometer that replaces the XRS/EBIT spectrometer that has been operating at EBIT since 2000. The ECS utilizes a 32-pixel x-ray calorimeter array from the XRS instrument on the Suzaku x-ray observatory. Eighteen of the pixels are optimized for the 0.1–10 keV band and yield 4.5 eV full width at half maximum energy resolution and 95% quantum efficiency at 6 keV. In addition, the ECS includes 14 detector pixels that are optimized for the high-energy band with a bandpass from 0.5 to over 100 keV with 34 eV resolution and 32% quantum efficiency at 60 keV. The ECS detector array is operated at 50 mK using a five stage cryogenic system that is entirely automated. The instrument takes data continuously for over 65 h with a 2.5 h recycle time. The ECS is a nondispersive, broadband, highly efficient spectrometer that is one of the prime instruments at the EBIT facility. The instrument is used for studies of absolute cross sections, charge exchange recombination, and x-ray emission from nonequilibrium plasmas, among other measurements in our laboratory astrophysics program.
ACCESSION #
35150251

 

Related Articles

  • The X-Ray Microcalorimeter Spectrometer for the International X-Ray Observatory. Kelley, R. L.; Bandler, S. R.; Doriese, W. B.; Ezoe, Y.; Fujimoto, R.; Gottardi, L.; den Hartog, R.; den Herder, J.-W.; Hoevers, H.; Irwin, K.; Ishisaki, Y.; Kilbourne, C. A.; de Korte, P.; van der Kuur, J.; Mitsuda, K.; Ohashi, T.; Piro, L.; Porter, F. S.; Sato, K.; Shinozaki, K. // AIP Conference Proceedings;12/16/2009, Vol. 1185 Issue 1, p757 

    The International X-Ray Observatory (IXO) is under formulation by NASA, ESA and JAXA for deployment in 2022. IXO emerged over the last 18 months as the NASA Constellation-X and ESA/JAXA X-Ray Evolving Universe Spectrometer (XEUS) missions were combined. The driving performance requirements for...

  • Large-Absorber TES X-ray Microcalorimeters and the Micro-X Detector Array. Eckart, M. E.; Adams, J. S.; Bandler, S. R.; Brekosky, R. P.; Brown, A.-D.; Chervenak, J. A.; Ewin, A. J.; Finkbeiner, F. M.; Kelley, R. L.; Kilbourne, C. A.; Porter, F. S.; Sadleir, J. E.; Smith, S. J.; Figueroa-Feliciano, E.; Wikus, P. // AIP Conference Proceedings;12/16/2009, Vol. 1185 Issue 1, p699 

    We present experimental results and designs of large-absorber transition-edge-sensor (TES) X-ray microcalorimeters. Much of our effort has focused on developing close-packed arrays of 250–300 μm-sized pixels suitable for the X-ray Microcalorimeter Spectrometer (XMS) on the...

  • Development of a microcalorimeter with transition edge sensor for detection of LX rays emitted by transuranium elements. Nakamura, Keisuke; Maeda, Makoto; Yasumune, Takashi; Maehata, Keisuke; Ishibashi, Kenji; Tanaka, Keiichi; Umeno, Takahiro; Takasaki, Koji; Momose, Takumaro // Radiation Protection Dosimetry;Jul2011, Vol. 146 Issue 1-3, p88 

    A transition edge sensor (TES) microcalorimeter has been developed for use as an energy dispersive X-ray spectrometer. The TES microcalorimeter is a thermal detector that enables one to determine the energy of an incident photon by measuring the resultant increase in temperature. In this work, a...

  • Optimal filtering, record length, and count rate in transition-edge-sensor microcalorimeters. Doriese, W. B.; Adams, J. S.; Hilton, G. C.; Irwin, K. D.; Kilbourne, C. A.; Schima, F. J.; Ullom, J. N. // AIP Conference Proceedings;12/16/2009, Vol. 1185 Issue 1, p450 

    In typical algorithms for optimally filtering transition-edge-sensor-microcalorimeter pulses, the average value of a filtered pulse is set to zero. The achieved energy resolution of the detector then depends strongly on the chosen length of the pulse record. We report experimental confirmation...

  • Transition edge sensors for imaging spectrometers. Hoevers, H. F. C. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p193 

    This paper describes single pixel microcalorimeters with a superconductor-to-normal phase transition thermometer, as developed for high resolution X-ray spectroscopy, and discusses the discrepancies between their theoretical and experimental performance. Moreover, the status and development of...

  • Status of X-ray microcalorimeter development at ISAS. Fujimoto, R.; Mitsuda, K.; Iyomoto, N.; Audley, M. D.; Miyazaki, T.; Oshima, T.; Yamazaki, M.; Futamoto, K.; Takei, Y.; Ishisaki, Y.; Kagei, T.; Hiroike, T.; Morita, U.; Ohashi, T.; Yamasaki, N. Y.; Kushino, A.; Kudo, H.; Sato, H.; Nakamura, T.; Goto, E. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p231 

    A superconducting phase-transition microcalorimeter is a promising detector for high resolution X-ray spectroscopy. We are developing such a detector for future Japanese X-ray astronomy missions. In our design, a tin absorber is electrodeposited as a mushroom structure to achieve a high covering...

  • Arraying compact pixels of transition-edge microcalorimeters for imaging x-ray spectroscopy. Stahle, C. K.; Lindeman, M. A.; Figueroa-Feliciano, E.; Li, M. J.; Tralshawala, N.; Finkbeiner, F. M.; Brekosky, R. P.; Chervenak, J. A. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p223 

    We are developing superconducting transition-edge sensor (TES) microcalorimeters for astronomical x-ray spectroscopy. We have obtained very high energy resolution (2.4 eV at 1.5 keV and 3.7 eV at 3.3 keV) in large, isolated TES pixels using Mo/Au proximity-effect bilayers on silicon-nitride...

  • Large Arrays of TES X-ray Microcalorimeters for Dark Baryon Search. Ezoe, Yuichiro; Yoshitake, Hiroshi; Ishikawa, Kumi; Ishisaki, Yoshitaka; Akamatsu, Hiroki; Ohashi, Takaya; Yamasaki, Noriko Y.; Mitsuda, Kazuhisa; Takano, Takayuki; Maeda, Ryutaro // AIP Conference Proceedings;12/16/2009, Vol. 1185 Issue 1, p60 

    Arrays of transition edge sensor (TES) X-ray microcalorimeters can provide a high energy resolution and a large area necessary for future dark baryon search missions such as DIOS (Diffuse Intergalactic Oxygen Surveyor). In the current design, the energy resolution of 2 eV at 0.3–1.5 keV...

  • First results from Position-Sensitive quantum calorimeters using Mo/Au Transition-Edge Sensors. Figueroa-Feliciano, Enectali; Chervenak, Jay; Finkbeiner, Fred M.; Li, Mary; Lindeman, Mark A.; Stahle, Caroline K.; Stahle, Carl M. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p239 

    We report the first results from a high-energy-resolution imaging spectrometer called a Position-Sensitive Transition-Edge Sensor (POST). A PoST is a quantum calorimeter consisting of two Transition Edge Sensors (TESs) on the ends of a long absorber to do one dimensional imaging spectroscopy....

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics