TITLE

Sensitivity of the integrating pulse magnetometer with a first-order gradiometer

AUTHOR(S)
Trojanowski, S.; Ciszek, M.
PUB. DATE
October 2008
SOURCE
Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p104702
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Inductive magnetometers used for measurements in pulsed magnetic fields should have proper frequency characteristics. In the present work we describe the construction of an inductive magnetometer for measurements of the magnetic moment in pulsed magnetic fields, together with the calculation procedures for determination of its sensitivity. We present a method for determination of the effective coefficient of the coupling between the coils set (gradiometer) and cylindrical samples, as well as a method for calculation of the thermal noise in the measuring system. The determination of the effective coupling coefficient permits a straightforward connection of the value of the measured signal with the magnetic moment of the sample and calibration of the gradiometer in absolute units. In the work we also present, as examples, some experimental hysteresis loops of pulse magnetization measurements for some ferromagnetic samples and a single crystal of high temperature superconductor. The results were obtained using our homemade pulse magnet and magnetometer with a gradiometer designed and constructed on basis of presented here calculations.
ACCESSION #
35150248

 

Related Articles

  • Microvibration sample magnetometer: A force-type measurement. Morais, P. C.; Köche, N. M. L.; Tronconi, A. L.; Skeff Neto, K. // Review of Scientific Instruments;Mar85, Vol. 56 Issue 3, p411 

    A simple microvibrating sample magnetometer (MVSM), particularly inexpensive, sensitive, and versatile has been developed. An alternating magnetic field superposed to a steady uniform magnetic field is applied to the sample. The sample undergoes a periodic motion around an equilibrium position,...

  • Use of a phase-sensitive detector for measuring magnetic hysteresis loops. Gömöry, Fedor // Review of Scientific Instruments;Aug1991, Vol. 62 Issue 8, p2019 

    A method for magnetic hysteresis loop measurement on small samples of high Tc superconductors is described, applicable to other types of magnetic materials as well. It is based on an unusual working regime of the phase-sensitive detector with a square wave mixer signal and controllable reference...

  • Feasibility Study for Elimination of the Screening Current-Induced Fields in HTS Coil. Kim, K.; Hahn, S.; Choi, Y.; Kim, Y.; Kang, D.; Kazikawa, K.; Lee, H. // Journal of Superconductivity & Novel Magnetism;Jan2015, Vol. 28 Issue 1, p83 

    Herein, we report a feasibility study for elimination of the screening current-induced field (SCIF) in fully insulated (INS) and no-insulation (NI) GdBCO coated conductor (CC) coils exposed to an external AC magnetic field generated by background solenoid copper coils. Prior to investigating the...

  • 30 Hz-10 kHz hysteresis loop tracer with field up to 0.1 T for high-T[sub c] superconductors. Ji, Z.M.; Wang, H.B.; Zhou, J.; Zhou, G.D.; Xu, W.W.; Cheng, Q.H.; Yang, S.Z.; Wu, P.H. // Review of Scientific Instruments;Jul97, Vol. 68 Issue 7, p2830 

    Describes a hysteresis loop tracer to measure the alternating current magnetization of high-critical temperature superconductors. Frequency range of the superconductors; Display of the hysteresis loops on an oscilloscope; Testing of the demagnetization factor, stability and the frequency...

  • Vector vibrating-sample magnetometer with permanent magnet flux source. Stamenov, P.; Coey, J. M. D. // Journal of Applied Physics;4/15/2006, Vol. 99 Issue 8, p08D912 

    A compact magnetometer, which uses two nested 1 T Halbach cylinders to generate a variable magnetic field of up to 2 T in any direction in the xy plane, has two sets of quadrupole pickup coils to detect the components mx and my of the magnetic moment of a sample vibrating along Oz. Sensitivity...

  • Active compensation in combination with weak passive shielding for magnetocardiographic measurements. Kuriki, S.; Hayashi, A.; Washio, T.; Fujita, M. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p440 

    We studied different schemes of noise reduction using active compensation of environmental magnetic field noises in order to develop a high-temperature-superconductor (HTS) magnetometer system for the measurement of magnetocardiographic signals. The active compensation was combined with weak...

  • Toroid magnetometer for high-critical-temperature superconductors (abstract). Cross, R. W.; Goldfarb, R. B. // Journal of Applied Physics;5/1/1990, Vol. 67 Issue 9, p5476 

    Presents an abstract of the study 'Toroid Magnetometer for High-Critical-Temperature Superconductors,' by R.W. Cross and R.B. Goldfarb.

  • How to measure Earth's magnetic field. Auster, Hans-Ulrich // Physics Today;Feb2008, Vol. 61 Issue 2, p76 

    This article briefly describes the methods and devices used to measure geomagnetic fields. Magnetic measurements are accomplished by a wide variety of magnetometers, usually coupled to digital data-acquisition systems. The discovery of the relation between proton precession and magnetic-field...

  • Measuring DC Fields as Low as 0.5 nT by Using Bi-2223 Polycrystalline Superconductors. Topal, Ugur; Alıkma, Fatma; Coker, E. // Journal of Superconductivity & Novel Magnetism;May2013, Vol. 26 Issue 5, p1831 

    In this study a novel type of magnetometer capable of direct measurement of DC fields as low as 0.5 nT was described. The second harmonic voltage generated by polycrystalline superconductors inserted in AC and DC fields was used as sensor signal. The experiments have shown that a 0.5 nT DC field...