TITLE

The use and characterization of a backilluminated charge-coupled device in investigations of pulsed x-ray and radiation sources

AUTHOR(S)
Fullagar, Wilfred; Uhlig, Jens; Walczak, Monika; Canton, Sophie; Sundström, Villy
PUB. DATE
October 2008
SOURCE
Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p103302
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Examinations of bremsstrahlung and energetic electron beams from a novel laser plasma source motivate and assist characterization of a backthinned, backilluminated direct detection x-ray charge-coupled device (CCD), a topology that is uncommon in hard x-ray work. Behavior toward pseudomonochromatic (55Fe) and multichromatic (241Am) sources is briefly reviewed under optimized noise conditions. Results collectively establish the previously unknown functional depth structure. Several modes of usage are illustrated in ∼4–20 keV x-ray laser plasma source investigations, where the significance of the characterization is briefly discussed. The spectral redistribution associated with this CCD topology is unfavorable, yet appropriate analysis ensures that sufficient spectral information remains for quantitative determination of broadband x-ray flux and spectra in essentially single laser shot measurements. The energy dependence of nascent electron cloud radii in silicon is determined using broadband x-rays from the laser plasma source, turning the narrow depletion depth to advantage. Finally, the characterization is used to quantify recent x-ray spectral explorations of the water jet laser plasma source operating under aspirator vacuum. These results will have key value for establishment of laboratory based ultrafast extended x-ray absorption fine structure experiments using microbolometric detectors.
ACCESSION #
35150246

 

Related Articles

  • Novel x-ray multispectral imaging of ultraintense laser plasmas by a single-photon charge coupled device based pinhole camera. Labate, L.; Giulietti, A.; Giulietti, D.; Köster, P.; Levato, T.; Gizzi, L. A.; Zamponi, F.; Lübcke, A.; Kämpfer, T.; Uschmann, I.; Förster, E. // Review of Scientific Instruments;Oct2007, Vol. 78 Issue 10, p103506 

    Spectrally resolved two-dimensional imaging of ultrashort laser-produced plasmas is described, obtained by means of an advanced technique. The technique has been tested with microplasmas produced by ultrashort relativistic laser pulses. The technique is based on the use of a pinhole camera...

  • High resolution soft x-ray spectroscopy of low Z K-shell emission from laser-produced plasmas. Dunn, J.; Magee, E. W.; Shepherd, R.; Chen, H.; Hansen, S. B.; Moon, S. J.; Brown, G. V.; Gu, M.-F.; Beiersdorfer, P.; Purvis, M. A. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E314 

    A large radius, R=44.3 m, high resolution grating spectrometer (HRGS) with 2400 lines/mm variable line spacing has been designed for laser-produced plasma experiments conducted at the Lawrence Livermore National Laboratory Jupiter Laser Facility. The instrument has been run with a low-noise,...

  • Broadband, high dynamics and high resolution charge coupled device-based spectrometer in dynamic mode for multi-keV repetitive x-ray sources. Fourment, C.; Arazam, N.; Bonte, C.; Caillaud, T.; Descamps, D.; Dorchies, F.; Harmand, M.; Hulin, S.; Petit, S.; Santos, J. J. // Review of Scientific Instruments;Aug2009, Vol. 80 Issue 8, p083505 

    We present a new operating mode, using a charged coupled device as dispersionless spectrometer dedicated to repetitive x-ray sources in the multi-keV domain. This enables to get spectra with high statistics in a short acquisition time and a way compatible with the operation of other diagnostics...

  • Spectroscopy of betatron radiation emitted from laser-produced wakefield accelerated electrons. Thorn, D. B.; Geddes, C. G. R.; Matlis, N. H.; Plateau, G. R.; Esarey, E. H.; Battaglia, M.; Schroeder, C. B.; Shiraishi, S.; Stöhlker, Th.; Tóth, C.; Leemans, W. P. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E325 

    X-ray betatron radiation is produced by oscillations of electrons in the intense focusing field of a laser-plasma accelerator. These hard x-rays show promise for use in femtosecond-scale time-resolved radiography of ultrafast processes. However, the spectral characteristics of betatron radiation...

  • Response of charge-coupled devices to direct electron bombardment. Stearns, D. G.; Wiedwald, J. D. // Review of Scientific Instruments;Jun89, Vol. 60 Issue 6, p1095 

    We report on the response of three scientific charge-coupled devices (CCD), the RCA SID501, the Tektronix TK512M, and the Texas Instruments 4849, to direct electron bombardment. A scanning electron microscope is used to provide a temporally gated, focused electron source of precise energy and...

  • Stigmatic spectrograph with a 2-D CCD detector for soft x-ray observations of laser produced plasmas. Villoresi, P.; Nicolosi, P. // Review of Scientific Instruments;Jun94, Vol. 65 Issue 6, p2049 

    Stigmatic spectroscopic observations of laser produced plasma have been performed in the 50-200 Ã… spectral interval. The purpose was to demonstrate the good instrumental performances of an intensified bidimensional detector installed on a stigmatic soft x-ray spectrometer. The latter is the...

  • Imaging of laser-plasma x-ray emission with charge-injection devices. Marshall, F. J.; Ohki, T.; McInnis, D.; Ninkov, Z.; Carbone, J. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p713 

    This work details the method of obtaining time-integrated images of laser–plasma x-ray emission using charge-injection devices (CIDs), as has been demonstrated on the University of Rochester’s 60-beam UV OMEGA laser facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)]. The...

  • X-ray sensitive charge-coupled device instrumentation for short and ultrashort pulse... Dunn, James; Young, Bruce K.F.; Shiromizu, Steven J. // Review of Scientific Instruments;Jan1995, Vol. 66 Issue 1, p706 

    Describes the use of x-ray sensitive charge coupled device (CCD) detectors for measuring emissions from high temperature plasmas produced at the L-division JANUS and USP laser facilities. Instruments based on commercially available video format cameras; Spatial resolution capability of the CCD...

  • Self-calibration of a thinned, backside illuminated charge coupled devices in the soft x-ray region. Yuelin Li; Tsakiris, G.D.; Sigel, R. // Review of Scientific Instruments;Jan1995, Vol. 66 Issue 1, p80 

    Presents a semi-empirical method of calibrating thinned, backside illuminated charge coupled device (CCD) chip in the soft x-ray region. Basis of determining the thickness of the dead layer; Use of continuum emission from laser produced plasmas; CCD camera system coupled to a transmission...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM