TITLE

Duplex multiwire proportional x-ray detector for multichord time-resolved soft x-ray and electron temperature measurements on T-10 tokamak

AUTHOR(S)
Sushkov, A. V.; Andreev, V. F.; Kravtsov, D. E.
PUB. DATE
October 2008
SOURCE
Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E319
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Compact 64-channel multiwire proportional chamber is successfully used on T-10 and TCV tokamaks as a continuous-current soft x-ray detectors. The duplex multiwire proportional x-ray detector is a new generation of these detectors. It has been designed for simultaneous multichord measurement of plasma soft x-ray emissivity in a two spectral ranges and determination of the electron temperature by the two-absorber method. The detector consists of two identical multiwire proportional chambers filled by 90%Kr+10%CH4 gas mixture at atmospheric pressure. The first multiwire chamber has 64 channels. The second multiwire chamber (installed behind the first one) has 32 channels. Both chambers view the plasma through the one helium-filled slot-hole camera. Thus, the first multiwire chamber serves as an absorber filter for the second one. Such construction of the detector allows us in addition to soft x-ray measurements to provide measurement of the plasma core electron temperature with spatial resolution of about 2 cm and a time resolution of less than 50 μs. The construction of the detector and experimental results illustrating the potential of the diagnostic are presented.
ACCESSION #
35150245

 

Related Articles

  • Soft x-ray tomography diagnostic for the Alcator C tokamak. Camacho, J. F.; Granetz, R. S. // Review of Scientific Instruments;Mar86, Vol. 57 Issue 3, p417 

    A soft x-ray tomography diagnostic has been built and operated on the Alcator C tokamak with the use of an 80-channel array of detectors. The detector system consists of miniature PIN photodiodes which are located around the periphery of the plasma at one toroidal location (top and bottom ports)...

  • A photodiode for the measurement of soft x-ray radiation from plasma. Qingjun Xiao; Navratil, Gerald // Review of Scientific Instruments;Sep96, Vol. 67 Issue 9, p3334 

    Reports on the use of photodiodes as detectors on the high beta tokamak-extended pulse tokamak for soft x-ray radiation measurement. Sawteeth instabilities and magnetohydrodynamic oscillations found in the signals from the photodiodes.

  • A multichord soft x-ray diagnostic for electron temperature profile measurements in RFX-mod. Bonomo, F.; Franz, P.; Murari, A.; Gadani, G.; Alfier, A.; Pasqualotto, R. // Review of Scientific Instruments;Oct2006, Vol. 77 Issue 10, p10F313 

    We report on the design and first results obtained with a multichord diagnostic for the measurement of the electron temperature profiles in RFX-mod. The diagnostic consists of four groups of five photodiodes each, measuring the soft x-ray plasma emissivity through four pinholes. Each pinhole...

  • High-resolution soft x-ray spectrometer for the NSTX tokamak. Beiersdorfer, P.; Bitter, M.; May, M. J.; Roquemore, L. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1974 

    A high-resolution spectrometer for measuring the soft x-ray emission (7-24 Ã…) has been implemented on the National Spherical Tokamak Experiment (NSTX). The instrument will be used to study the K-shell spectra of O, Ne, and Mg as well as the L-shell spectra of Fe and Ni and to calibrate...

  • A Z Pinch-Based Source of Selective Soft X Rays. Zaitsev, V.I.; Volkov, G.S. // Instruments & Experimental Techniques;Jul/Aug2004, Vol. 47 Issue 4, p498 

    A setup for metrological measurements of X rays in the energy range of 50-1000 eV is described. A Z pinch with a discharge time of a few microseconds is used as the X-ray source. Radiation of a given energy is selected with the help of multilayer X-ray mirrors in combination with special X-ray...

  • Characterization of compact bright soft X-ray source based on picosecond laser plasma. Magunov, A. I.; Batani, D.; Faenov, A. Y.; Lucchini, G.; Desai, T.; Padoan, F.; Pikuz, T. A.; Skobelev, I. Y.; Canova, F.; Chiodini, N. // Applied Physics B: Lasers & Optics;Jan2006, Vol. 82 Issue 1, p19 

    Radiation emission of silicon and aluminum plasmas produced by 40-ps laser pulses with peak intensity above 1014 W/cm2 was studied. High-resolution soft X-rayspectra of H-like and He-like ions were analyzed to determine plasma parameters. We compared the line shape of resonance transitions and...

  • A UHV Apparatus for Soft X-ray Spectroscopy with Symmetry Selection for Solids and Surfaces. Takata, Y.; Tokushima, T.; Harada, Y.; Kamakura, N.; Kitajima, Y.; Nagasono, M.; Tamenori, Y.; Ohashi, H.; Hiraya, A.; Ishiguro, E.; Shin, S.; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p1186 

    A UHV apparatus for soft x-ray spectroscopic studies on solids and surfaces has been constructed at the beamline BL27SU in SPring-8. A newly developed flat field spectrometer with a CCD detector is equipped for soft X-ray emission spectroscopy (SXES). The focused beam, less than 10μm in...

  • A beam intensity monitor for the evaluation beamline for soft x-ray optical elements. Imazono, Takashi; Moriya, Naoji; Harada, Yoshihisa; Sano, Kazuo; Koike, Masato // AIP Conference Proceedings;7/12/2012, Vol. 1465 Issue 1, p38 

    Evaluation Beamline for Soft X-Ray Optical Elements (BL-11) at the SR Center of Ritsumeikan University has been operated to measure the wavelength and angular characteristics of soft x-ray optical components in a wavelength range of 0.65-25 nm using a reflecto-diffractometer (RD). The beam...

  • Calibration of a high resolution grating soft x-ray spectrometer. Magee, E. W.; Dunn, J.; Brown, G. V.; Cone, K. V.; Park, J.; Porter, F. S.; Kilbourne, C. A.; Kelley, R. L.; Beiersdorfer, P. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E314 

    The calibration of the soft x-ray spectral response of a large radius of curvature, high resolution grating spectrometer (HRGS) with a back-illuminated charge-coupled device detector is reported. The instrument is cross-calibrated for the 10-50 Ã… waveband at the Lawrence Livermore National...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics