TITLE

Application of a digital pileup resolving method to high count rate neutron measurements

AUTHOR(S)
Belli, Francesco; Esposito, Basilio; Marocco, Daniele; Riva, Marco; Zimbal, Andreas
PUB. DATE
October 2008
SOURCE
Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E515
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The possibility of working in high count rate conditions is an important issue for neutron measurements applied to fusion experiments in order to extend the measurement dynamic range and time resolution. One of the main issues of high count rate operation is the overlapping of closely spaced events (pileup) that produces a distortion in their amplitude and therefore in the pulse height spectra. The usual way to deal with such pileup events using standard analog electronics is to reject them in the energy analysis process. Thanks to digital acquisition techniques, the waveforms of pileup events can be recorded and elaborated in order to reconstruct the contributing original single events. This work presents the results of the application of a pileup resolving method for the reconstruction and analysis of overlapping events to pulses acquired digitally from a NE213 liquid scintillator detector. The measurements have been carried out at the PTB accelerator facility with 14 MeV neutrons at total count rates over 400 kHz.
ACCESSION #
35150231

 

Related Articles

  • Cosmic-ray Muon Flux In Belgrade. Banjanac, R.; Dragić, A.; Joković, D.; Udovičić, V.; Puzović, J.; Aničin, I. // AIP Conference Proceedings;2007, Vol. 899 Issue 1, p543 

    Two identical plastic scintillator detectors, of prismatic shape (50×23×5)cm similar to NE102, were used for continuous monitoring of cosmic-ray intensity. Muon ΔE spectra have been taken at five minute intervals, simultaneously from the detector situated on the ground level and from...

  • Measurement on light yield of liquid scintillator based on p-xylene. He Li-ping; Luo Xuan; Fang Yu; Zhi-jun Wei; Liu Dong-xiao; Lin Zhang; Xin Li // Applied Mechanics & Materials;2014, Issue 513-517, p4185 

    The relative light output of liquid scintillator based on p-xylene(PX) was measured in this paper. The setup for testing on light output was clearly displayed. The results showed that the light yield increased as the addition of the second solute p-bis(o-methylatyryl)- benzene(bis-MSB). Bis-MSB...

  • The use of energy information in plastic scintillator material. Ely, J.; Anderson, K.; Bates, D.; Kouzes, R.; Lo Presti, C.; Runkle, R.; Siciliano, E.; Weier, D. // Journal of Radioanalytical & Nuclear Chemistry;Jun2008, Vol. 276 Issue 3, p743 

    Plastic scintillator material is often used for gamma-ray detection in many applications due to its relatively good sensitivity and cost-effectiveness compared to other detection materials. However, due to the dominant Compton scattering interaction mechanism, full energy peaks are not observed...

  • Radiation Hardness of a Fast Neutron Scintillation Spectrometer with a Stilbene Crystal. Klimenkov, E. E.; Kashchuk, Yu. A.; Krasil'nikov, A. V.; Oleinikov, A. A.; Sevast'yanov, V. D.; Trykov, L. A.; Semenova, N. N. // Instruments & Experimental Techniques;Mar/Apr2004, Vol. 47 Issue 2, p166 

    Neutron detectors with organic oscillators such as stilbene crystals are suggested for use in measuring the characteristics of neutron radiation in the International Thermonuclear Experimental Reactor (ITER). These detectors will be used as neutron-flux monitors in a multichannel neutron...

  • Double-Differential Cross Sections for the Production of Neutrons from Pb, W, Zr, Cu, and Al Targets Irradiated with 0.8-, 1.0-, and 1.6-GeV Protons. Trebukhovsky, Yu. V.; Titarenko, Yu. E.; Batyaev, V. F.; Mulambetov, R. D.; Mulambetova, S. V.; Smirnov, G. N.; Lipatov, K. A.; Koldobsky, A. B.; Zhivun, V. M.; Barashenkov, V. S.; Kumawat, H.; Mashnik, S. G.; Prael, R. E. // Physics of Atomic Nuclei;Jan2005, Vol. 68 Issue 1, p3 

    Experimental results obtained by determining the double-differential cross sections for neutron production in Pb, W, Zr, Cu, and Al targets irradiated with 0.8-, 1.0-, and 1.6-GeV protons are presented. The spectra of neutrons were measured at 15°, 30°, 60°, 90°, 120°, and 150°...

  • Neutron measurements on Joint European Torus using an NE213 scintillator with digital pulse shape discrimination. Esposito, B.; Bertalot, L.; Marocco, D.; Riva, M.; Kaschuck, Y.; Skopintsev, S.; Zimbal, A.; Reginatto, M.; Schuhmacher, H.; Adams, J. M.; Murari, A. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3550 

    A digital pulse shape discrimination system (DPSD) has been used in conjunction with collimated NE213 scintillators for neutron spectroscopic measurements at high count rates (MHz range) in Joint European Torus discharges (DD and DT fueled, neutral beam injection and rf heated). The system,...

  • Modification of ROSPEC to cover neutrons from thermal to 18 MeV. Ing, H.; Djeffal, S.; Clifford, T.; Li, L.; Noulty, R.; Machrafi, R. // Radiation Protection Dosimetry;Aug2007, Vol. 126 Issue 1-4, p350 

    Rotating Spectrometer (ROSPEC) is a neutron spectrometer designed to measure neutron energy distributions, and provide accurate neutron dosimetry. It is a completely self-contained unit and measures neutron energy via recoiling protons in gas proportional counters. Each of the four original gas...

  • The TOFOR neutron spectrometer and its first use at JET. Gatu Johnson, M.; Giacomelli, L.; Hjalmarsson, A.; Weiszflog, M.; Sundén, E. Andersson; Conroy, S.; Ericsson, G.; Hellesen, C.; Källne, J.; Ronchi, E.; Sjöstrand, H.; Gorini, G.; Tardocchi, M.; Murari, A.; Popovichev, S.; Sousa, J.; Pereira, R. C.; Combo, A.; Cruz, N. // Review of Scientific Instruments;Oct2006, Vol. 77 Issue 10, p10E702 

    A time-of-flight neutron spectrometer (TOFOR) has been developed to measure the 2.45 MeV d+d→3He+n neutron emission from D plasmas. The TOFOR design features the capability to operate at high rates in the 100 kHz range, data collection with fast time digitizing and storing, and monitoring...

  • A method for evaluating personal dosemeters in workplace with neutron fields. de Freitas Nascimento, Luana; Cauwels, Vanessa; Vanhavere, Filip // Radiation Protection Dosimetry;Apr2012, Vol. 149 Issue 2, p159 

    Passive detectors, as albedo or track-etch, still dominate the field of neutron personal dosimetry, mainly due to their low-cost, high-reliability and elevated throughput. However, the recent appearance in the market of electronic personal dosemeters for neutrons presents a new option for...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics