TITLE

Investigating the possibility of a monitoring fast ion diagnostic for ITER

AUTHOR(S)
De Angelis, R.; von Hellermann, M. G.; Orsitto, F. P.; Tugarinov, S.
PUB. DATE
October 2008
SOURCE
Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E517
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
In burning plasma fusion devices, fast ion transport plays a central role in the performances of the machines. Moreover the losses of energetic particles might cause severe damages on plasma facing components. Therefore real time measurements of fast ion transport would provide valuable information for safe and reliable plasma operations. In this paper, we examine the feasibility of a monitoring system based on active charge exchange recombination spectroscopy making use of the 0.5 MeV/amu ITER heating neutral beams for detecting fast 4He+2 (alphas) particles in ITER plasmas. There are two time scales relevant to fast ion dynamics: the first is the slowing down time of the distribution function which is of the order of 1 s, and the second is the time scale of burstlike transport events such as collective Alfvén mode excitations, which—for typical ITER plasma parameters—can be as low as 0.2–1 ms. To detect such fast events a broadband high-throughput spectrometer is needed, while for the reconstruction of the alpha velocity distribution function a higher resolution spectrometer and longer integration time are necessary. To monitor a spatial redistribution of fast particles due to the propagation of the instability, it is proposed to use a limited number of spatial channels, looking at the charge exchange He II spectra induced by the heating beams, whose energy matches the slowing down energies of fast particles. The proposal is to share the motional stark effect periscope on equatorial port 3 [A. Malaquias et al., Rev. Sci. Instrum. 75, 3393 (2004)] adding additional fibers and suitable instruments. A signal to noise ratio of 5 could be achieved with a spatial resolution of a/15 and a time resolution of 5 ms, in a broad spectral band of 100 Å, corresponding to the spectral broadening of the line emitted by alpha particles with energies ΔE<=1.5 MeV. Fast H and D ion populations created by heating neutral beam or ion cyclotron resonance heating are expected to produce significantly lower charge exchange signal levels and can only be monitored on substantially longer time scales as it is expected because of the strong energy difference with respect to the heating neutral beam and the consequently low charge exchange cross sections.
ACCESSION #
35150229

 

Related Articles

  • Method for neutral spectra analysis taking ripple-trapped particle losses into account. Dnestrovskij, A.Yu.; Bengtson, Roger D.; Ouroua, A.; Karzhavin, Yuri // Review of Scientific Instruments;Jan1995, Vol. 66 Issue 1, p363 

    Proposes an analysis technique of charge exchange neutral spectra to obtain ion temperatures of a tokamak plasma. Modeling of the deviation of ion distribution; Analysis code used to analyze active charge exchange data.

  • Calculation of low-Z impurity pellet induced fluxes of charge exchange neutral particles escaping from magnetically confined toroidal plasmas. Goncharov, P. R.; Ozaki, T.; Sudo, S.; Tamura, N.; Tolstikhina, I. Yu.; Sergeev, V. Yu. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10F312 

    Measurements of energy- and time-resolved neutral hydrogen and helium fluxes from an impurity pellet ablation cloud, referred to as pellet charge exchange or PCX experiments, can be used to study local fast ion energy distributions in fusion plasmas. The estimation of the local distribution...

  • Non-statistical simulations for neutral beam spectroscopy in fusion plasmas. Marchuk, O.; Ralchenko, Yu.; Schultz, D. R.; Delabie, E.; Urnov, A. M.; Biel, W.; Janev, R. K.; Schlummer, T. // AIP Conference Proceedings;5/25/2012, Vol. 1438 Issue 1, p169 

    While most of the existing models for calculation of neutral beam emission and attenuation in a fusion plasma assume a statistical distribution of population for the excited states of the beam, the observed motional Stark effect data reveal significant deviations from the statistical...

  • Ion energy distribution functions of vacuum arc plasmas. Byon, Eungsun; Anders, André // Journal of Applied Physics;2/15/2003, Vol. 93 Issue 4, p1899 

    The velocity distribution function of vacuum arc ions can be measured by a time-of-flight technique. The measuring principle makes use of the well-justified assumption that the ion drift velocity from the cathode spot region to a collector is approximately constant. It is shown that the negative...

  • New understanding of poloidal rotation measurements in a Tokamak plasma. Bell, R. E.; Synakowski, E. J. // AIP Conference Proceedings;2000, Vol. 547 Issue 1, p39 

    Significant atomic physics corrections to the measured poloidal velocity using charge exchange spectroscopy have been neglected when interpreting impurity poloidal velocity. In the presence of a magnetic field, the gyro motion of the impurity ion along with the finite lifetime of the observed...

  • The NSTX fast-ion D-alpha diagnostic. Podestà, M.; Heidbrink, W. W.; Bell, R. E.; Feder, R. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E521 

    A new diagnostic, aimed at energy-resolved measurements of the spatial and temporal dynamics of fast ions in NSTX plasmas, is described. It is based on active charge-exchange recombination spectroscopy. The fast-ion signal is inferred from light emitted in the wavelength range of the Dα line...

  • Wide-view charge exchange recombination spectroscopy diagnostic for Alcator C-Mod. Rowan, W. L.; Bespamyatnov, I. O.; Granetz, R. S. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10F529 

    This diagnostic measures temperature, density, and rotation for the fully stripped boron ion between the pedestal top and the plasma core with resolution consistent with the profile gradients. The diagnostic neutral beam used for the measurements generates a 50 keV, 6 A hydrogen beam. The...

  • On comparison of spectroscopically deduced central ion temperatures and plasma rotation at JET. Danielsson, M.; von Hellermann, M. G.; Källne, E.; Mandl, W.; Morsi, H. W.; Summers, H. P.; Zastrow, K.-D. // Review of Scientific Instruments;Apr92, Vol. 63 Issue 4, p2241 

    It is shown that a significant increase in the consistency of charge exchange spectroscopy and xray spectroscopy data for central ion temperature and plasma rotation is obtained when allowance is made for the following: (i) The charge exchange cross-section dependence on the impact energy of the...

  • Extraction of poloidal velocity from charge exchange recombination spectroscopy measurements. Solomon, W. M.; Burrell, K. H.; Gohil, P.; Groebner, R. J.; Baylor, L. R. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3481 

    An approach has been implemented on the DIII-D tokamak to allow the correct determination of the plasma poloidal velocity from charge exchange spectroscopy measurements. Unlike usual techniques, the need for detailed atomic physics calculations to properly interpret the results is alleviated....

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics