ABSTRACT
The Electron Beam Ion Trap (EBIT) facility at the Lawrence Livermore National Laboratory is being used to absolutely calibrate the transmission efficiency of x-ray filters employed by diodes and spectrometers used to diagnose laser-produced plasmas. EBIT emits strong, discrete monoenergetic lines at appropriately chosen x-ray energies. X rays are detected using the high resolution EBIT Calorimeter Spectrometer (ECS), developed for LLNL at the NASA/Goddard Space Flight Center. X-ray filter transmission efficiency is determined by dividing the x-ray counts detected when the filter is in the line of sight by those detected when out of the line of sight. Verification of filter thickness can be completed in only a few hours, and absolute efficiencies can be calibrated in a single day over a broad range from about 0.1 to 15 keV. The EBIT calibration lab has been used to field diagnostics (e.g., the OZSPEC instrument) with fully calibrated x-ray filters at the OMEGA laser. Extensions to use the capability for calibrating filter transmission for the DANTE instrument on the National Ignition Facility are discussed.
ACCESSION #
35150215

 

Related Articles

  • One-dimensional time resolved soft x-ray imaging of colliding plasmas in a laser heated cavity Eagleton, R. T.; Foster, J. M.; Rosen, P. A.; Graham, P. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p834 

    Describes x-ray streak camera measurements of wall motion and plasma filling in hohlraum targets heated by the AWE HELEN laser. Soft x-ray imaging; Design of the streak camera; One-dimensional numerical simulation and modeling.

  • X-ray yield scaling studies performed on the OMEGA laser. Workman, J.; Kyrala, G. A. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p678 

    We have performed experiments with planar targets on the OMEGA laser facility at the University of Rochester. These experiments investigated the scaling of x-ray yield and conversion efficiency with the laser energy and focusing properties for several different target materials. The experiments...

  • Density profile of the ablating plasma produced by soft x-ray irradiation. Nishikino, M.; Shiraga, H.; Matsuoka, M.; Fujioka, S.; Shigemori, K.; Nakai, M.; Azechi, H.; Miyanaga, N.; Yamanaka, T.; Nakai, S. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p653 

    Indirect/direct-hybrid irradiation has been proposed for suppressing the initial imprint of laser-irradiation nonuniformities. Indirect soft x-ray preirradiation of the target generates a plasma expansion layer on the target surface. When the drive laser beam comes later, the target has a...

  • X-ray imaging techniques on Z using the Z-Beamlet laser. Bennett, G. R.; Landen, O. L.; Adams, R. F.; Porter, J. L.; Ruggles, L. E.; Simpson, W. W.; Wakefield, C. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p657 

    The Z-Beamlet laser backlighter system at Sandia National Laboratories, which will be operational in 2001, will create a point or area source of high (or moderate) energy x rays behind a Z-accelerator [R. B. Spielman et al., Phys. Plasmas 5, 2105 (1998)] -driven target. In the former case with...

  • Generation of hard x rays by ultrafast terawatt lasers. Guo, T.; Spielmann, Ch.; Walker, B. C.; Barty, C. P. J. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p41 

    A compact, tabletop terawatt Ti:sapphire laser drive, ultrafast hard x-ray source for time-resolved x-ray diffraction studies is described. With a copper target the energy conversion efficiency from laser photons (800 nm) to copper K x-ray radiation (1.54 Ã…) is 0.008%. The optimal laser...

  • Fourier-space image processing for spherical experiments on OMEGA (invited). Smalyuk, V. A.; Boehly, T. R.; Iwan, L. S.; Kessler, T. J.; Knauer, J. P.; Marshall, F. J.; Meyerhofer, D. D.; Stoeckl, C.; Yaakobi, B.; Bradley, D. K. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p635 

    Studies of compressed shell integrity of spherical targets on the 60-beam 30 kJ UV OMEGA laser system involve spatially and temporally resolved measurements of core emission at different x-ray energies. Hot-core emission backlights a titanium-doped shell that is imaged at x-ray energies above...

  • Diagnostics for first plasma and development plan on KSTAR. Lee, J. H.; Na, H. K.; Lee, S. G.; Bak, J. G.; Seo, D. C.; Seo, S. H.; Oh, S. T.; Ko, W. H.; Chung, J.; Nam, Y. U.; Lee, K. D.; Ka, E. M.; Oh, Y. K.; Kwon, M.; Jeong, S. H. // Review of Scientific Instruments;Jun2010, Vol. 81 Issue 6, p063502 

    The first plasma with target values of the plasma current and the pulse duration was finally achieved on June 13, 2008 in the Korea Superconducting Tokamak Advanced Research (KSTAR). The diagnostic systems played an important role in achieving successful first plasma operation for the KSTAR...

  • Operation of target diagnostics in a petawatt laser environment (invited). Stoeckl, C.; Glebov, V. Yu.; Jaanimagi, P. A.; Knauer, J. P.; Meyerhofer, D. D.; Sangster, T. C.; Storm, M.; Sublett, S.; Theobald, W.; Key, M. H.; MacKinnon, A. J.; Patel, P.; Neely, D.; Norreys, P. A. // Review of Scientific Instruments;Oct2006, Vol. 77 Issue 10, p10F506 

    The operation of target diagnostics in a high-energy petawatt laser environment is made challenging by the large number of energetic electrons, hard x rays, and energetic particles produced in laser-target interactions. The charged particles and x rays from the target create secondary radiation...

  • Different methods of reconstructing spectra from filtered x-ray diode measurements. Seifter, Achim; Kyrala, George A. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10F323 

    Filtered x-ray diodes, sensitive in different spectral regions, are used to measure the emission spectrum of laser-driven hohlraums at the Omega laser facility in Rochester, NY. Here we present two new methods to reconstruct the emission spectra from the response of the x-ray diodes and compare...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics