TITLE

Flat field anomalies in an x-ray charge coupled device camera measured using a Manson x-ray source

AUTHOR(S)
Haugh, M. J.; Schneider, M. B.
PUB. DATE
October 2008
SOURCE
Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E925
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The static x-ray imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the x rays produced by lasers hitting a gold foil target. The intensity distribution taken by the SXI camera during a NIF shot is used to determine how accurately NIF can aim laser beams. This is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The charge coupled device (CCD) chip is an x-ray sensitive silicon sensor, with a large format array (2k×2k), 24 μm square pixels, and 15 μm thick. A multianode Manson x-ray source, operating up to 10 kV and 10 W, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/ΔE≈10. The x-ray beam intensity was measured using an x-ray photodiode that has an accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The x-ray beam provides full CCD illumination and is flat, within ±1% maximum to minimum. The spectral efficiency was measured at ten energy bands ranging from 930 to 8470 eV. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation occurred at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was not observable below 4 keV. We were also able to observe debris, damage, and surface defects on the CCD chip. The Manson source is a powerful tool for characterizing the imaging errors of an x-ray CCD imager. These errors are quite different from those found in a visible CCD imager.
ACCESSION #
35150073

 

Related Articles

  • A new method to calibrate the absolute sensitivity of a soft X-ray streak camera. Jian Yu; Shenye Liu; Jin Li; Zhiwen Yang; Ming Chen; Luting Guo; Li Yao; Shali Xiao // Review of Scientific Instruments;Dec2016, Vol. 87 Issue 12, p1 

    In this paper, we introduce a new method to calibrate the absolute sensitivity of a soft X-ray streak camera (SXRSC). The calibrations are done in the static mode by using a small laser-produced X-ray source. A calibrated X-ray CCD is used as a secondary standard detector to monitor the X-ray...

  • A comparison of glass fluorescers used to measure a pulsed ultraviolet image at F/2. Deniz, A. V.; Stamper, J. A. // Review of Scientific Instruments;Apr2001, Vol. 72 Issue 4, p1993 

    We built and characterized an instrument to measure the output profile of a pulsed KrF laser. The laser beam is focused onto a ∼1-mm-thick fluorescer, and the resulting fluorescence is imaged by a charge coupled device (CCD) camera. We tested 21 materials for efficiency, linearity, and...

  • Extended Field Laser Confocal Microscopy (EFLCM): Combining automated Gigapixel image capture with in silico virtual microscopy. Flaberg, Emilie; Sabelström, Per; Strandh, Christer; Szekely, Laszlo // BMC Medical Imaging;2008, Vol. 8, Special section p1 

    Background: Confocal laser scanning microscopy has revolutionized cell biology. However, the technique has major limitations in speed and sensitivity due to the fact that a single laser beam scans the sample, allowing only a few microseconds signal collection for each pixel. This limitation has...

  • Fabrication of 3-μm diameter pin hole array (PHA) on thick W substrates. Levato, T.; Pathak, N. C.; Cecchetti, C. A.; Ciricosta, O.; Koester, P.; Labate, L.; Giulietti, A.; Giulietti, D.; De Angelis, F.; Di Fabrizio, E.; Delogu, P.; Gizzi, L. A. // AIP Conference Proceedings;2/2/2010, Vol. 1209 Issue 1, p59 

    Pin-hole arrays are used for a variety of applications including, for example, X-ray imaging of laser-plasmas for fusion relevant studies [1]. More recently, a novel X-ray imaging technique has been proposed (this conference L. A. Gizzi et al.) within the High Power Laser Energy Research...

  • Implementation of a near backscattering imaging system on the National Ignition Facility. Mackinnon, A. J.; McCarville, T.; Piston, K.; Niemann, C.; Jones, G.; Reinbachs, I.; Costa, R.; Celeste, J.; Holtmeier, G.; Griffith, R.; Kirkwood, R.; MacGowan, B.; Glenzer, S. H.; Latta, M. R. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p4183 

    A near backscattering imaging diagnostic system is being implemented on the first quad of beams on the National Ignition Facility. This diagnostic images diffusing scatter plates, placed around the final focus lenses on the National Ignition Facility target chamber, to quantitatively measure the...

  • Laser Beam Analysis Using Image Processing. Alsultanny, Yas A. // Journal of Computer Science;2006, Vol. 2 Issue 1, p109 

    The laser beam profiles captured by CCD camera processed and analyzed by using 2Dgraphic and displayed on the monitor. The analysis of the He-Ne profiles and laser diode profiles are presented. The results showed that the He-Ne laser emits a pure Gaussian beam, whereas the diode laser emits an...

  • Simulation of the detection of underwater objects from air. A. Kovalev; A. Liberman; S. Moskalyuk // Measurement Techniques;Sep2007, Vol. 50 Issue 9, p960 

    Abstract  Simulation modelling of the detection through a water-air boundary of underwater objects by means of a CCD camera is performed. The situation using active illumination by pulses of laser radiation is considered. Calculation is performed for the special case of the minimum size of...

  • Discharge instability induced by external laser preionization of a XeF discharge laser. Takahashi, E.; Kato, S.; Matsumoto, Y.; Okuda, I. // Applied Physics B: Lasers & Optics;Feb2010, Vol. 98 Issue 2/3, p501 

    External-laser-induced preionization of excimer lasers was investigated. A discharge XeF laser was preionized by two different UV lasers [a KrF laser ( λ=249 nm) and an ArF laser ( λ=193 nm)], and the improvements in performance of the XeF laser were compared. The XeF laser beam profiles...

  • X-ray generation from 50-mJ, 120-ps KrF laser-produced plasmas. Broughton, J. N.; Fedosejevs, R. // Journal of Applied Physics;2/1/1992, Vol. 71 Issue 3, p1153 

    Presents a study that investigated the generation of x-rays from the interaction of low-energy laser pulses with solid targets. Details of the experiment; Experimental results; Discussion.

Share