TITLE

Reliable and repeatable characterization of optical streak cameras

AUTHOR(S)
Charest, Michael R.; Torres, Peter; Silbernagel, Christopher T.; Kalantar, Daniel H.
PUB. DATE
October 2008
SOURCE
Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10F546
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Optical streak cameras are used as primary diagnostics for a wide range of physics and laser experiments at facilities such as the National Ignition Facility. To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electrical components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases, the characterization data are applied to the raw data images to correct for the nonlinearities. In order to characterize an optical streak camera, a specific set of data is collected, where the response to defined inputs are recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, and temporal resolution from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information.
ACCESSION #
35150031

 

Related Articles

  • Ultrafast x-ray imaging with sliced sampling streak cameras. Huang, T. X.; Nakai, M.; Shiraga, H.; Azechi, H.; Ding, Y. K.; Zheng, Z. J. // Review of Scientific Instruments;Feb2006, Vol. 77 Issue 2, p026105 

    The ultrafast imaging methods in sliced sampling streak cameras are investigated. It is shown that the sampling-image x-ray streak camera has potential advantages in highly time-resolved and space-resolved imaging for imploded core plasmas. An optimized sampling method is presented to acquire...

  • A versatile high-resolution x-ray imager (HRXI) for laser-plasma experiments on OMEGA. Bourgade, J. L.; Troussel, P.; Casner, A.; Huser, G.; Sangster, T. C.; Pien, G.; Marshall, F. J.; Fariaud, J.; Remond, C.; Gontier, D.; Chollet, C.; Zuber, C.; Reverdin, C.; Richard, A.; Jaanimagi, P. A.; Keck, R. L.; Bahr, R. E.; Armstrong, W. J.; Dewandel, J.; Maroni, R. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E904 

    A high-resolution x-ray imager (HRXI) devoted to laser-plasma experiments combines two state-of-the-art technologies developed in France: a high-resolution x-ray microscope and a high-speed x-ray streak camera. The resulting streaked imager achieves spatial and temporal resolutions of ∼5...

  • Temporal dispersion of a spectrometer. Visco, A.; Drake, R. P.; Froula, D. H.; Glenzer, S. H.; Pollock, B. B. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10F545 

    The temporal dispersion of an optical spectrometer has been characterized for a variety of conditions related to optical diagnostics to be fielded at the National Ignition Facility (e.g., full-aperture backscatter station, Thomson scattering). Significant time smear is introduced into these...

  • Observation of asymmetrically imploded core plasmas with a two-dimensional sampling image x-ray streak camera. Shiraga, Hiroyuki; Lee, Myongdok; Mahigashi, Norimitsu; Fujioka, Shinsuke; Azechi, Hiroshi // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E920 

    A shell target with a cone for guiding the heating beam has been proposed for the fast ignition scheme. Implosion of such target is no longer symmetric because of the cone. A fast two-dimensional x-ray imaging technique, two-dimensional (2D) sampling image x-ray streak camera was applied for the...

  • Anisotropic, transparent fluoroapatite ceramics for high-power laser applications.  // American Ceramic Society Bulletin;Dec2012, Vol. 91 Issue 9, p17 

    The article offers information on research conducted by a team from the U.S. Lawrence Livermore National Laboratory on the use of antisotropic, transparent fluoroapatite ceramics in high-power lasers. The study assessed the efficiency of ceramics in igniting a thermonuclear reaction in a fuel...

  • Setup and performance of a streak camera apparatus for transient absorption measurements in the ns to ms range. Kutta, Roger-Jan; Langenbacher, Thomas; Kensy, Uwe; Dick, Bernhard // Applied Physics B: Lasers & Optics;May2013, Vol. 111 Issue 2, p203 

    We describe the setup and performance of an apparatus for simultaneous time- and spectrally resolved measurements of transient absorption. The key component in this apparatus is a streak camera, yielding, for every excitation of the sample, a two-dimensional data array with 512 × 512 data...

  • Nonlinear optical input–output characteristics of 1.55 μm injection-locked vertical-cavity surface-emitting lasers. Onishi, Y.; Koyama, F.; Nishiyama, N.; Caneau, C.; Zah, C.E. // Applied Physics Letters;4/26/2004, Vol. 84 Issue 17, p3247 

    The optical input–output characteristics of a 1.55 μm vertical-cavity surface-emitting laser (VCSEL) with external light injection to its fundamental mode were investigated. Appropriate wavelength detuning of external light enables abrupt modal switching in an injection-locked VCSEL....

  • The motional Stark effect diagnostic on NSTX. Levinton, F. M.; Yuh, H. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10F522 

    This work describes the implementation and recent results from the motional Stark effect (MSE) collisionally induced fluorescence diagnostic on NSTX. Due to the low magnetic field on NSTX the MSE diagnostic requires a new approach for the viewing optics and spectral filter. This has been...

  • The next generation of electron cyclotron emission imaging diagnostics (invited). Zhang, P.; Domier, C. W.; Liang, T.; Kong, X.; Tobias, B.; Shen, Z.; Luhmann, N. C.; Park, H.; Classen, I. G. J.; van de Pol, M. J.; Donné, A. J. H.; Jaspers, R. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10F103 

    A 128 channel two-dimensional electron cyclotron emission imaging system collects time-resolved 16×8 images of Te profiles and fluctuations on the TEXTOR tokamak. Electron cyclotron emission imaging (ECEI) is undergoing significant changes which promise to revolutionize and extend its...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics