TITLE

Metallurgical Studies on Cracked Al–5.5Zn–2.5Mg–1.5Cu Aluminum Alloy Injector Disc of Turbine Rotor

AUTHOR(S)
Jha, Abhay K.; Sreekumar, K.
PUB. DATE
August 2008
SOURCE
Journal of Failure Analysis & Prevention;Aug2008, Vol. 8 Issue 4, p327
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The high-strength aluminum alloy Al–5.5Zn–2.5Mg–1.5Cu (AA 7075) is extensively used in aerospace applications. An injector body of a gas generator for a turbine rotor in a liquid propulsion system was fabricated out of AA 7075 forgings in the T7352 condition, and, subsequent to a qualification hot test, one of the injector discs showed the presence of cracks on the top face of the body. Detailed metallurgical investigation indicated that the failure was caused by stress-corrosion cracking (SCC).
ACCESSION #
35075876

 

Related Articles

  • Stress Corrosion Cracking Behavior of Friction-Stir-Welded Al 6061-T651. Sunggon Lim; Sangshik Kim; Chang-Gil Lee; Sungjoon Kim // Metallurgical & Materials Transactions. Part A;Jul2005, Vol. 36 Issue 7, p1977 

    In the present study, the stress corrosion cracking (SCC) behavior of friction-stir-welded Al 6061-T651 alloy was examined in 3.5 pct NaCl aqueous solution at an applied potential of -650 mV vs Ag/AgCl using a slow strain rate testing technique. The resistance to SCC was correlated to the...

  • Corrosion resistances of stressed building structures made of aluminum alloys. Sinyavskii, V. S.; Kalinin, V. D. // Protection of Metals;Nov2007, Vol. 43 Issue 6, p572 

    Propagation of various types of localized corrosion on real stressed building structures was examined. The naturally aged 1915T alloy used in such structures was found to be highly resistant under various atmospheric conditions. It was insensitive to corrosion cracking and exfoliation corrosion,...

  • INFLUENCE OF THE SELECTED STRUCTURAL PARAMETER ON A DEPTH OF INTERGRANULAR CORROSION OF Al-Si7-Mg 0,3 ALUMINUM ALLOY. BERNAT, L. // Metalurgija;Jan2016, Vol. 55 Issue 1, p25 

    The paper presents an influence of the Dendrite Arm Spacing (DAS) microstructure parameter on the intergranular corrosion of AlSi7Mg aluminum alloy. The samples were subjected to the corrosion process for: 2,5; 12; 24; 48 and 96 hours in NaCl + HCl + H2O solution. It was noted that the DAS...

  • Effect of Micro Arc Oxidation Treatment on the Corrosion and Stress Corrosion Cracking (SCC) Behaviours of AA7020-T6 Aluminum Alloy in 3.5% NaCl Solution. Venugopal, A.; Narayanan, P. Ramesh; Sharma, S. C.; George, Koshy M. // Materials Science Forum;2015, Vol. 830-831, p639 

    Alumina coating was formed on AA7020 aluminum alloy by micro arc oxidation (MAO) method and its corrosion and stress corrosion cracking (SCC) behaviors were examined in 3.5 wt. % NaCl solution. Potentiodynamic polarization (PP) was used to evaluate the corrosion resistance of the coating and...

  • Characterization of Intergranular Corrosion Defects in a 2024 T351 Aluminum Alloy. de Bonfils-Lahovary, M. L.; Laffont, L.; Blanc, C. // Materials Science Forum;2017, Vol. 877, p444 

    In the 2xxx series alloys, intergranular corrosion is generally related to the strong reactivity of copper-rich intergranular precipitates leading to a copper enrichment of these particles. While the nature of the oxides formed inside the intergranular corrosion defects was assumed to strongly...

  • Past LPB articles on corrosion.  // Loss Prevention Bulletin;Dec2015, Issue 246, p11 

    A list of articles on corrosion previously published in the journal is presented including "Hazards of Corrosion," "Stress Corrosion Cracking of Stainless Steel," and "Failure of Backup Systems."

  • Effect of pulsed electric current treatment on corrosion of structural metals. Babutskii, A.; Chrysanthou, A.; Ioannou, J. // Strength of Materials;Jul2009, Vol. 41 Issue 4, p387 

    Results of corrosion tests of structural metals previously treated using pulsed electric current of high density are presented. According to the data obtained, the treatment substantially affects corrosion of metals. In cases of HSLA steel and 5182 aluminum alloy, an increase of corrosion...

  • Effect of Micro Arc Oxidation Coatings on Corrosion Resistance of 6061-Al Alloy. Wasekar, Nitin P.; Jyothirmayi, A.; Krishna, L. Rama; Sundararajan, G. // Journal of Materials Engineering & Performance;Oct2008, Vol. 17 Issue 5, p708 

    In the present study, the corrosion behavior of micro arc oxidation (MAO) coatings deposited at two current densities on 6061-Al alloy has been investigated. Corrosion in particular, simple immersion, and potentiodynamic polarization tests have been carried out in 3.5% NaCl in order to evaluate...

  • Marine Corrosion and Protection of Aluminum Alloys According to Their Composition and Structure. Sinyavskii, V.; Kalinin, V. // Protection of Metals;Jul2005, Vol. 41 Issue 4, p317 