TITLE

Agreement between two Goldmann type applanation tonometers

PUB. DATE
November 2008
SOURCE
Indian Journal of Ophthalmology;Nov2008, Vol. 56 Issue 6, p516
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
No abstract available.
ACCESSION #
34972489

 

Related Articles

  • Comparison between standard Goldmann applanation prism and disposable applanation prism in tonometry. Goel, S.; Chua, C.; Dong, B.; Butcher, M.; Ahiat, F.; Hindi, S. K.; Kotta, S. // Eye;Feb2004, Vol. 18 Issue 2, p175 

    Background Disposable devices are increasingly becoming the preferred choice where possible in contact medical equipment.Aim To evaluate the accuracy of the disposable applanation tonometer head as a potential substitute to the standard Goldmann applanation head.Methods The study was...

  • Clinical evaluation of the pressure phosphene tonometer in patients with glaucoma. Rielveld, E.; van den Bremer, D. A.; Völker-Dieben, H. J. // British Journal of Ophthalmology;May2005, Vol. 89 Issue 5, p537 

    Aim: To evaluate the reliability of the, pressure phosphene tonometer in comparison with the Goldmann applanation tonometer. Methods: 45 consecutive patients with glaucoma (78 eyes) participated in the study. Eyes with previous eye surgery, a documented peripheral visual field defect, a...

  • Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer. Gunvant, P.; Baskaran, M.; Vijaya, I.; Joseph, I. S.; Watkins, R. J.; Nallapothula, M.; Broadway, D. C.; O'Leary, D. J. // British Journal of Ophthalmology;Apr2004, Vol. 88 Issue 4, p518 

    Aims: To investigate the effect of central corneal thickness and corneal curvature on intraocular pressure measurements using the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer, and to assess the agreement between the pulsatile ocular blood How tonograph and the...

  • Comparison of Luneau SA disposable and Goldmann applanation tonometer readings. Baddon, A. C. J.; Osborne, S. F.; Quah, S. A.; Batterbury, M.; Wong, D. // Eye;Jun2007, Vol. 21 Issue 6, p789 

    PurposeTo test the agreement of intraocular pressure (IOP) measurements made with Luneau SA applanators and Goldmann applanator.Materials and MethodsA single-blind crossover trial. IOPs were measured in both eyes of subjects with both applanators. Type of applanator was alternated to eliminate...

  • Comparison of the ICare® rebound tonometer with the Goldmann applanation tonometer by experienced and inexperienced tonometrists. Abraham, L. M.; Epasinghe, N. C. R.; Selva, D.; Casson, R. // Eye;Apr2008, Vol. 22 Issue 4, p503 

    PurposeTo assess the agreement between ICare® rebound tonometer and Goldmann applanation tonometer in the hands of experienced and inexperienced tonometrists.Patients and methodsTwo tonometrists, experienced with both Goldmann applanation tonometry (GAT) and ICare® Tonometry (ICT) measured...

  • Abstracts.  // Journal of Pediatric Ophthalmology & Strabismus;May/Jun2009, Vol. 46 Issue 3, p188 

    The article presents abstracts of two studies related to pediatric ophthalmology including the comparison of intraocular pressure measurements obtained by rebound tanometer and Goldmann applanation tonometer in children with congenital glaucoma and the effectiveness of simultaneous surgery in...

  • Factors affecting tonometry measurement. Hamilton-Maxwell, Kirsten // Optometry Today;4/11/2014, Vol. 54 Issue 7, p50 

    The article discusses the use of the tonometer for measuring intraocular pressure (IOP) and the factors that affect tonometry results. It differentiates between contact and non-contact tonometry (NCT) and the variables to consider for measuring such as the patient's eye, the type of instrument,...

  • Use of disposable prism tonometry in routine clinical practice. Salvi, S. M.; Sivakumar, S.; Sidiki, S. S. // Eye;Jul2005, Vol. 19 Issue 7, p743 

    Aim: To establish the reliability, efficacy, and safety of disposable prism tonometry and validate its routine use for screening as well as monitoring of glaucoma. Methodology: Intraocular pressure (IOP) of 400 eyes of 200 consecutive patients who attended the general...

  • Glaucoma Diagnosis and Monitoring. Fechtner, Robert D. // Ophthalmology Times;3/1/2004 Supplement, Vol. 29, p3 

    Focuses on the diagnosis and monitoring of glaucoma. Identification of intraocular pressure (IOP) as the causal risk factor for the development of glaucoma; Consideration of the Goldmann applanation tonometer as the standard method for measuring IOP; Influence of corneal thickness on applanation...

  • The utility of rebound tonometer in late elderly subjects. Rei Sakata; Jiro Numaga // Clinical Interventions in Aging;2014, Vol. 9, p227 

    Background: To compare intraocular pressure (IOP) readings using the Icare rebound tonometer (RBT) versus the Goldmann applanation tonometer (GAT) in late elderly (aged 75 years or older) subjects with or without glaucoma, and to evaluate the influence of central corneal thickness (CCT) on IOP...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics