TITLE

Grazing incidence surface-induced dissociation: molecules sliding along a surface

AUTHOR(S)
Zulauf, Alexander; Schmidt, Lothar; Jungclas, Hartmut
PUB. DATE
November 2008
SOURCE
Analytical & Bioanalytical Chemistry;Nov2008, Vol. 392 Issue 5, p793
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Principles of grazing incidence SID and a brief overview of previous works are summarized and the experimental setup for grazing incidence SID experiments is described. New results with fullerene C60 are presented; these demonstrate that grazing incidence SID is not a special case of the conventional SID.
ACCESSION #
34851689

 

Related Articles

  • Are the time resolutions for the conventional and the pseudorandom methods for time-of-flight analysis different? Verheij, Laurens K.; Zeppenfeld, Peter // Review of Scientific Instruments;Nov87, Vol. 58 Issue 11, p2138 

    The pseudorandom method for time-of-flight analysis has the advantage over the conventional method of a greatly improved efficiency, but, according to previous theory, the disadvantage that the time resolution is worse. Here we present an improved theory of pseudorandom modulation. We show that...

  • Fullerenes coated with sulfur and phosphorous molecules. Tast, F.; Malinowski, N. // Journal of Chemical Physics;6/8/1997, Vol. 106 Issue 22, p9372 

    Investigates clusters composed of a single fullerene molecule and several phosphorus or sulfur molecules produced in a low pressure inert gas aggregation cell. Use of vacuum-ultraviolet photoionization time-of-flight mass spectrometry; Indication of the formation of a layer on the fullerene...

  • Pulsed discharge in a hollow cathode with the detection of ions in a time-of-flight mass spectrometer: Analytical capabilities in the analysis of solid samples. Ganeev, A. A.; Kuz'menkov, M. A.; Lyubimtsev, V. A.; Potapov, S. V.; Drobyshev, A. I.; Potemin, S. S.; Voronov, M. V. // Journal of Analytical Chemistry;May2007, Vol. 62 Issue 5, p444 

    The results of a study of a new analytical system that includes an ion source with a hollow-cathode pulsed gas discharge and a time-of-flight mass spectrometer are reported. It was found that such a system can be successfully used for the direct analysis of metal and dielectric solid samples....

  • Low-Noise High-Accuracy TOF Laser Range Finder. Nejad, Shahram Mohammad; Olyaee, Saeed // American Journal of Applied Sciences;2008, Vol. 5 Issue 7, p755 

    This paper presents a new low-noise high-accuracy laser range finder based on the Time-Of-Flight (TOF) method. A Q-switched Nd:YAG laser at 1064 nm as a source and a SLIK avalanche photodiode as a detector are used. The optical section of the system including ZnS/MgF2 optical filter, designed by...

  • Time-of-flight energy analyzer for the plasma potential measurements by a heavy ion beam diagnostic. Nedzelskiy, I. S.; Malaquias, A.; Gonçalves, B.; Silva, C.; Varandas, C. A. F.; Cabral, J. A. C. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3514 

    A time-of-flight (TOF) technique for the plasma potential measurements by a heavy ion beam diagnostic (HIBD) with a multiple cell array detector has been elaborated on tokamak ISTTOK as an alternative to the traditional electrostatic energy analyzer. This article describes the design and...

  • Avalanche photodiode based time-of-flight mass spectrometry. Keiichi Ogasawara; Livi, Stefano A.; Desai, Mihir I.; Ebert, Robert W.; McComas, David J.; Walther, Brandon C. // Review of Scientific Instruments;Aug2015, Vol. 86 Issue 8, p1 

    This study reports on the performance of Avalanche Photodiodes (APDs) as a timing detector for ion Time-of-Flight (TOF) mass spectroscopy. We found that the fast signal carrier speed in a reach-through type APD enables an extremely short timescale response with a mass or energy independent <2 ns...

  • Time-of-flight emission profiles of the entire plume using fast imaging during pulsed laser deposition of YBa2Cu3O7-x. Druffner, Carl J.; Perram, Glen P.; Biggers, Rand R. // Review of Scientific Instruments;Sep2005, Vol. 76 Issue 9, p093101 

    Emission time-of-flight (TOF) profiles have been obtained using gated imagery to further the process control during the pulsed laser deposition of the high temperature superconductor, YBa2Cu3O7-x. An intensified charge coupled device array was used to obtain a sequence of plume images at 10 ns...

  • Correlation time-of-flight spectrometry of ultracold neutrons. Novopol'tsev, M. I.; Pokotilovski, Yu. N. // Instruments & Experimental Techniques;Sep2010, Vol. 53 Issue 5, p635 

    The features of the correlation method used in time-of-flight spectrometry of ultracold neutrons are analyzed. The time-of-flight spectrometer for the energy range of ultracold neutrons is described, and results of its testing by measuring spectra of neutrons passing through interference filters...

  • Determination of impurities in uranium matrices by time-of-flight ICP-MS using matrix-matched method. Bürger, S.; Riciputi, L.; Bostick, D. // Journal of Radioanalytical & Nuclear Chemistry;Dec2007, Vol. 274 Issue 3, p491 

    The analysis of impurities in uranium matrices is performed in a variety of fields, e.g., for quality control in the production stream converting uranium ores to fuels, as element signatures in nuclear forensics and safeguards, and for non-proliferation control. We have investigated the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics