TITLE

Electrosynthesized, non-conducting films of poly(2-naphthol): electrochemical and XPS investigations

AUTHOR(S)
Ciriello, Rosanna; Guerrieri, Antonio; Pavese, Filomena; Salvi, Anna Maria
PUB. DATE
November 2008
SOURCE
Analytical & Bioanalytical Chemistry;Nov2008, Vol. 392 Issue 5, p913
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Advanced biosensors are frequently based on electrosynthesized polymeric films. In this context, the electrosynthesis mechanism underlying the electrochemical oxidation of 2-naphthol (2-NAP) in phosphate buffer at pH 7 on Pt electrodes has been investigated. The voltammetric behaviour suggested the formation of a non-conducting polymer (poly(2-NAP)) through an irreversible electrochemical process complicated by 2-NAP adsorption and fast electrode passivation. Repeat experiments showed the passive films to be strongly adherent to the Pt surface with thicknesses of approximately 10 nm, as estimated by in-situ electrochemical quartz crystal microbalance (EQCM) measurements and by X-ray photoelectron spectroscopy (XPS). The polymer structure was then investigated by XPS, which gave evidence of the presence of naphthalene rings bonded through poly(oxide) groups (C–O–C) and of quinonoid groups, probably present as the ends of polymeric chains. The polymer repeat unit and terminal groups derived by XPS analysis are in accordance with electrochemical results and with synthesis routes reported for phenol-derived compounds in aqueous solution. XPS also gave evidence of a large excess of oxygen, probably arising from water molecules entrapped by the polymeric chains, as suggested by angle-resolved XPS and thermal treatment of poly(2-NAP)/Pt film under ultra-high vacuum (UHV).
ACCESSION #
34851679

 

Related Articles

  • Disposable Non-Enzymatic Glucose Sensors Using Screen-Printed Nickel/Carbon Composites on Indium Tin Oxide Electrodes. Won-Yong Jeon; Young-Bong Choi; Hyug-Han Kim // Sensors (14248220);Dec2015, Vol. 15 Issue 12, p31083 

    Disposable screen-printed nickel/carbon composites on indium tin oxide (ITO) electrodes (DSPNCE) were developed for the detection of glucose without enzymes. The DSPNCE were prepared by screen-printing the ITO substrate with a 50 wt% nickel/carbon composite, followed by curing at 400 C for 30...

  • Phase-frequency relationships in oscillating quartz microbalance electrodes: Determination of an... Komplin, Glenn C.; Pietro, William J. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1131 

    Presents a systematic study of the effects of overtone harmonic, operating frequency, and electrode surface area on mass sensitivity of liquid-phase quartz-crystal microbalance (QCM) operation. Complex impedance measurements; Electrical characteristics of the QCM; Complex impedance of...

  • A microchip based fluoride sensor based on the use of CdO doped ferric oxide nanocubes. Rahman, Mohammed; Khan, Sher; Asiri, Abdullah // Microchimica Acta;Feb2015, Vol. 182 Issue 3/4, p487 

    CdO-doped FeO nanocubes (NCs) were prepared by a hydrothermal method using reducing precursors in alkaline medium, and characterized by UV/vis, FT-IR, Raman, and X-ray photoelectron spectroscopy, by X-ray powder diffraction, energy-dispersive X-ray spectroscopy, and field-emission scanning...

  • Low Leakage Current Transport and High Breakdown Strength of Pulsed Laser Deposited HfO2/SiC Metal-Insulator-Semiconductor Device Structures. Hullavarad, S. S.; Pugel, D. E.; Jones, E. B.; Vispute, R. D.; Venkatesan, T. // Journal of Electronic Materials;Jun2007, Vol. 36 Issue 6, p648 

    Hafnium oxide (HfO2) thin films were deposited by the pulsed laser deposition (PLD) method on SiC substrates. The bandgap of HfO2 thin films was observed to be 5.8 eV. The chemical nature and stoichiometry of the films were analyzed by x-ray photoelectron spectroscopy (XPS)....

  • Conduction band offset at GeO2/Ge interface determined by internal photoemission and charge-corrected x-ray photoelectron spectroscopies. Zhang, W. F.; Nishimula, T.; Nagashio, K.; Kita, K.; Toriumi, A. // Applied Physics Letters;3/11/2013, Vol. 102 Issue 10, p102106 

    We report a consistent conduction band offset (CBO) at a GeO2/Ge interface determined by internal photoemission spectroscopy (IPE) and charge-corrected X-ray photoelectron spectroscopy (XPS). IPE results showed that the CBO value was larger than 1.5 eV irrespective of metal electrode and...

  • Quartz crystal microbalance immunosensor for the detection of antibodies to double-stranded DNA. Fakhrullin, Rawil F.; Vinter, Victor G.; Zamaleeva, Alsu I.; Matveeva, Maria V.; Kourbanov, Roustem A.; Temesgen, Belayhun K.; Ishmuchametova, Dilara G.; Abramova, Zinaida I.; Konovalova, Olga A.; Salakhov, Myakzyum K. // Analytical & Bioanalytical Chemistry;May2007, Vol. 388 Issue 2, p367 

    We report the development of a novel quartz crystal microbalance immunosensor with the simultaneous measurement of resonance frequency and motional resistance for the detection of antibodies to double-stranded DNA (dsDNA). The immobilization of poly( l-lysine) and subsequent complexation with...

  • Bioanalytical device based on cholesterol oxidase-bonded SAM-modified electrodes. Parra, A.; Casero, E.; Pariente, F.; Vázquez, L.; Lorenzo, E. // Analytical & Bioanalytical Chemistry;Jul2007, Vol. 388 Issue 5/6, p1059 

    A rapid, simple and reproducible two-step method for constructing cholesterol biosensors by covalently bonding cholesterol oxidase (ChOx) to a 3,3′-dithiodipropionic acid di( N-succinimidyl ester) (DTSP)-modified gold electrode is described. Exhaustive characterizations of both the...

  • Motion of redox molecules in solution monitored by the highly-sensitive EQCM technique. Asakura, Noriyuki; Kamachi, Toshiaki; Okura, Ichiro // Research on Chemical Intermediates;2006, Vol. 32 Issue 3/4, p341 

    The behavior of redox molecules in solution that was not detected by electrochemical techniques was measured by a highly-sensitive electrochemical quartz crystal microbalance (EQCM) technique that has been improved in this study to obtain a high sensitivity of EQCM measurement in solution. The...

  • Electrochemical Characteristics of a 7-Ferrocenyl(carbonyloxy)-1-Heptanethiol-Modified Gold Electrode. Rahman, Mohammed Muzibur; Jeon, Il Cheol // Turkish Journal of Chemistry;2007, Vol. 31 Issue 1, p17 

    The electrochemical properties of 7-ferrocenyl(carbonyloxy)-1-heptanethiol [FcCO2(CH2)7SH] were characterized by an electrochemical quartz crystal microbalance (EQCM). A gold surface was modified with FcCO2(CH2)7SH by the self-assembly method. EQCM was used to investigate mass change during the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library