TITLE

Lateral External Fixation--A New Surgical Technique for Displaced Unreducible Supracondylar Humeral Fractures in Children

AUTHOR(S)
Slongo, Theddy; Schmid, Timo; Wilkins, Kaye; Joeris, Alexander
PUB. DATE
August 2008
SOURCE
Journal of Bone & Joint Surgery, American Volume;Aug2008, Vol. 90-A Issue 8, p1690
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Percutaneous Kirschner wire fixation represents the classic treatment for displaced supracondylar humeral fractures in childhood. This type of treatment first requires satisfactory reduction of the fracture. Failure to achieve a satisfactory reduction or inadequate stabilization can result in instability of the fracture fragments, which can result in either an unsatisfactory cosmetic or functional outcome. In our experience, these problems can be overcome with the use of a small lateral external fixator. Methods: Between 1999 and 2005, thirty-one of 170 Gartland type-III supracondylar humeral fractures were treated with a lateral external fixator. The outcome of treatment was analyzed with regard to limb alignment, elbow movement, cosmetic appearance, and patient satisfaction. Results: In twenty-eight of the thirty-one patients, a satisfactory reduction was achieved with closed methods. All children except one had a normal or good range of movement. The cosmetic result was excellent in all cases. All of the children and their parents stated that they would choose this treatment again. Conclusions: The use of a small lateral external fixator seems to be a safe alternative for the treatment of displaced supracondylar fractures of the humerus when a closed reduction appears to be unattainable by means of manipulation alone or when sufficient stability is not achieved with standard methods of Kirschner wire fixation. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
ACCESSION #
34412599

 

Related Articles

  • Comparison of Surgical Outcomes in Thoracolumbar Fractures Operated with Posterior Constructs Having Varying Fixation Length with Selective Anterior Fusion. Hak Sun Kim; Seung Yup Lee; Nanda, Ankur; Ju Young Kim; Jin Oh Park; Seong Hwan Moon; Hwan Mo Lee; Ho Joong Kim; Huan Wei; Eun Su Moon // Yonsei Medical Journal;8/31/2009, Vol. 50 Issue 4, p546 

    Purpose: Surgical treatment in the case of thoracolumbar burst fractures is very controversial. Posterior instrumentation is most frequently used, however, but the number of levels to be instrumented still remains a matter of debate. Materials and Methods: A total of 94 patients who had a single...

  • Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware. Windolf, Markus; Klos, Kajetan; Wähnert, Dirk; van der Pol, Bas; Radtke, Roman; Schwieger, Karsten; Jakob, Roland P. // BMC Musculoskeletal Disorders;2010, Vol. 11, p95 

    Background: Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence")...

  • Triplane fractures of the ankle. Patel, Shelain; Haddad, Fares // British Journal of Hospital Medicine (17508460);Jan2009, Vol. 70 Issue 1, p36 

    Triplane fractures are fractures that occur in three planes. They occur in the adolescent population, with the ankle joint most frequently involved. Early recognition of the complex fracture pattern and appropriate treatment thereafter will maximize the chances of a favourable outcome.

  • Comparison of Autogenous Bone Graft and Endothermic Calcium Phosphate Cement for Defect Augmentation in Tibial Plateau Fractures. Russell, Thomas A.; Leighton, Ross K. // Journal of Bone & Joint Surgery, American Volume;Oct2008, Vol. 90-A Issue 10, p2057 

    Background: Bone graft augmentation is often selected to treat defects associated with unstable tibial plateau fractures. This prospective, randomized, multicenter study was undertaken to determine the efficacy of bioresorbable calcium phosphate cement compared with standard autogenous iliac...

  • UNSTABLE FRACTURE OF RADIUS AND ULNA OUTCOME OF INTRAMEDULLARY KIRSCHNER WIRE FIXATION IN CHILDREN. ALAM, WAQAR; ALI SHAH, FAAIZ; DURRANI, ZAFAR; ASKAR, ZAHID; AYAZ KHAN, MUHAMMAD; HAYAT, SIKANDAR // Professional Medical Journal;May2011, Vol. 18 Issue 2, p323 

    Objectives: To know the functional outcome of Intramedullary Kirschner Wire fixation of unstable Radius-Ulna fractures in children. Study Design: Descriptive study. Period: 27/03/2009 to 26/03/2010. Setting: Department of Orthopedic and Trauma, Khyber Teaching Hospital, Peshawar. Patients and...

  • A Simple and Light Weight External Fixator for Distraction Advancement Manoplasty. Nazerani, Shahram; Kalantar Motamedi, Mohammad Hosein; Ebrahimpoor, Adel; Vahedian, Jalal; Nazerani, Tara; Nazerani, Tina; Bidarmaghz, Bardia // Kowsar Medical Journal;Fall2012, Vol. 17 Issue 3, p353 

    Background: With the growing interest in long bone distraction several types of distractors have been introduced; all have the same principle of an outer structure which acts like a scaffold and the distracting mechanism is a separate device which is mounted on this outer structure. Objectives:...

  • Finite element analysis of a subtrochanteric fractured femur with dynamic hip screw, dynamic condylar screw, and proximal femur nail implants – a comparative study. Sowmianarayanan, S.; Chandrasekaran, A.; Kumar, R. Krishna // Proceedings of the Institution of Mechanical Engineers -- Part H;Jan2008, Vol. 222 Issue 1, p117 

    Selection of the correct type of implant for fracture fixation has become a very interesting problem in the orthopaedic community. The present work studies the biomechanical behaviour of the femur with three different implant configurations for simple transverse subtrochanteric fracture and the...

  • Long bone fractures treated by traditional bonesetters: a study of patients' behaviour. Solagberu, Babatunde A. // Tropical Doctor;Apr2005, Vol. 35 Issue 2, p106 

    This is a study of 295 patients (23.1% of 1278 patients with long bone fractures) who had visited the traditional bonesetter (TBS). The initial idea of visiting TBS was mooted by an external person in 75% of cases, whereas to discharge from TBS was usually the patient's idea. The reasons for a...

  • Torsional stability of interference screws derived from bovine bone - a biomechanical study. Bauer, Joscha; Efe, Turgay; Herdrich, Silke; Gotzen, Leo; El-Zayat, Bilal Farouk; Schmitt, Jan; Timmesfeld, Nina; Schofer, Markus Dietmar // BMC Musculoskeletal Disorders;2010, Vol. 11, p82 

    Background: In the present biomechanical study, the torsional stability of different interference screws, made of bovine bone, was tested. Interference screws derived from bovine bone are a possible biological alternative to conventional metallic or bioabsorbable polymer interference screws....