TITLE

Linked Elbow Replacement: A Salvage Procedure for Distal Humeral Nonunion

AUTHOR(S)
Cil, Akin; Veilette, Christian J. H.; Sanchez-Sotelo, Joaquin; Morrey, Bernard F.
PUB. DATE
September 2008
SOURCE
Journal of Bone & Joint Surgery, American Volume;Sep2008, Vol. 90-A Issue 9, p1939
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Nonunion is a challenging and not uncommon complication of distal humeral fractures. Our long-term experience with linked semiconstrained total elbow arthroplasty as a salvage procedure for patients with distal humeral nonunion not amenable to internal fixation was investigated. Methods: Ninety-one consecutive patients (ninety-two elbows) underwent total elbow arthroplasty for the treatment of a distal humeral nonunion, and the results were reviewed at a mean of 6.5 years postoperatively. Patients' charts and anteroposterior and lateral radiographs made prior to and immediately after the joint replacement and at the time of the latest follow-up were reviewed to identify intraoperative and postoperative complications, and radiographic evidence of loosening or bushing wear. The outcome measures consisted of prosthetic survival, with implant removal as the end point for failure, and the Mayo Elbow Performance Score (MEPS). Results: At the time of the most recent follow-up, joint stability had been initially restored in all patients, including nine who had had a grossly flailed elbow. Sixty-seven (74%) of the patients had no pain or mild pain at the time of the latest follow-up, whereas seventy-nine patients (87%) had had moderate or severe pain prior to the surgery. While 85% (seventy-seven) of the ninety-one patients rated the outcome as better or much better, twenty patients (22%) had a fair or poor MEPS. A total of forty-four complications occurred in forty elbows, and there were thirty-two reoperations, twenty-three of which involved implant revision or removal. Factors that increased the risk of implant failure were a patient age of less than sixty-five years, two or more prior surgical procedures, and a history of infection. The rate of prosthetic survival without removal or revision for any reason was 96% at two years, 82% at five years, and 65% at both ten and fifteen years. Conclusions: Linked semiconstrained total elbow arthroplasty is a salvage procedure that can provide pain relief and restore motion and function in patients with a distal humeral nonunion that is not amenable to internal fixation. Substantial risk factors for failure include an age of less than sixty-five years, multiple previous surgical procedures, and any history of infection.
ACCESSION #
34230454

 

Related Articles

  • Allograft-Prosthesis Composite for Revision of Catastrophic Failure of Total Elbow Arthroplasty. Mansat, Pierre; Adams, Robert A.; Morrey, Bernard F. // Journal of Bone & Joint Surgery, American Volume;Apr2004, Vol. 86-A Issue 4, p724 

    Background: Revision of a failed total elbow arthroplasty is a challenging procedure, often associated with bone deficiency. The purpose of this investigation was to review our experience with a composite allograft-implant reconstruction for patients with a failed total elbow arthroplasty....

  • POLYETHYLENE WEAR AFTER TOTAL ELBOW ARTHROPLASTY. Lee, Brian P.; Adams, Robert A.; Morrey, Bernard F. // Journal of Bone & Joint Surgery, American Volume;May2005, Vol. 87-A Issue 5, p1080 

    Background: Articular wear is considered to be a possible long-term complication of the use of stemmed, coupled elbow replacements with the capacity to correct deformity and restore function. There have been no reports on this topic, to our knowledge. Methods: A review of the results of 919...

  • INTRINSIC CONSTRAINT OF UNLINKED TOTAL ELBOW REPLACEMENTS--THE ULNOTROCHLEAR JOINT. Kamineni, S.; O'Driscoll, S. W.; Urban, M.; Garg, A.; Berglund, L. J.; Morrey, B. F.; An, K. N. // Journal of Bone & Joint Surgery, American Volume;Sep2005, Vol. 87-A Issue 9, p2019 

    Background: Many unlinked total elbow replacement designs with radically differing articular geometries exist, suggesting that there is no consensus regarding an optimal design. A feature inherent to the articular design is the intrinsic constraint afforded to the joint by the implant. Our aim...

  • Elbow arthroplasty results reliable in short-term, but less so at longer follow-up. Rapp, Susan M. // Orthopedics Today;Jun2008, Vol. 28 Issue 6, p69 

    The article discusses research on total elbow arthroplasty (TEA). It references a study by Robin R. Richards presented at the 8th Annual Advances in Arthritis, Arthroplasty and Trauma in Arlington, Virginia in September 2007. Richards said that TEA may not last beyond a few years, noting that...

  • Revision total elbow arthroplasty with the linked Coonrad-Morrey total elbow arthroplasty: a retrospective study of twenty procedures. Plaschke, Hans; Thillemann, Theis; Belling-Sørensen, Anne; Olsen, Bo // International Orthopaedics;May2013, Vol. 37 Issue 5, p853 

    Purpose: In this retrospective study we evaluated the short- to medium-term results after 20 Coonrad-Morrey revision total elbow arthroplasties (TEAs). Methods: We included a consecutive series of revision TEAs performed at our institution from 2004 to 2010. At a mean follow-up of 4.4 years,...

  • Débridement Arthroplasty for Primary Osteoarthritis of the Elbow. Wada, Takuro; Isogai, Satoshi; Ishii, Seiichi; Yamashita, Toshihiko // Journal of Bone & Joint Surgery, American Volume;Mar2005 Supplement 1, Vol. 87-A, p95 

    BACKGROUND: Formal and more aggressive débridement procedures have been described for the treatment of advanced primary osteoarthritis of the elbow. However, the literature contains little information on the results of long-term follow-up. The purpose of this study was to evaluate outcomes at...

  • Total Elbow Replacement as Primary Treatment for Complex Fractures of the Distal Osteopenic Humerus. Müller, Lars Peter; Dietz, Sven-Oliver; Rommens, Pol Maria; Morrey, Bernhard F. // European Journal of Trauma;Apr2003, Vol. 29 Issue 2, p63 

    Background: The use of hip and shoulder arthroplasty in elderly patients for grossly displaced intraarticular fractures is becoming more and more accepted. Total elbow replacement (TER) has not been considered an option for the treatment of extensively comminuted fractures of the distal humerus...

  • Primary Souter-Strathclyde Total Elbow Prosthesis in Rheumatoid Arthritis. van der Lugt, J. C. T.; Geskus, R. B.; Rozing, P. M. // Journal of Bone & Joint Surgery, American Volume;Mar2005 Supplement 1, Vol. 87-A, p67 

    BACKGROUND: Total elbow arthroplasty is a well-established treatment for the painful elbow joint in patients with rheumatoid arthritis. We present the results of what we believe to be the first prospective study of the Souter­Strathclyde total elbow prosthesis. METHODS: Between June 1982 and...

  • The Results of ulnohumeral arthroplasty in elbow osteoarthritis. Dehghani, M.; Rouzbahani, E. // Journal of Mazandaran University of Medical Sciences (JMUMS);2008, Vol. 18 Issue 64, p11 

    Background and Purpose: Osteoarthritis (OA) of elbow is not common but can be disabling, if it is not responding to non-operative methods. Several surgical methods are suggested (joint debridment, ulnohumeral arthroplasty, fusion and total elbow arthroplasty). In this study, we evaluated the...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics