ABSTRACT
Background: Clinical observations suggest that metal-on-metal arthroplasties that have been implanted for more than twenty years do fail. It is proposed that there are not two, but three distinct phases of wear life for any metal-on-metal implant system: bedding-in, steady state, and end point. In this study, we asked two questions: can we explain late failure due to wear, and will there be a late failure mechanism due to a change in the frictional torque? Methods: In order to characterize wear failure, an analysis was made of five retrieved metal-on-metal couples that were mapped with use of a roundness machine. A geometrical model was developed on the basis of these observations, and wear at the end point was calculated. The literature on first-generation metal-on-metal implants retrieved for aseptic loosening was reviewed to assess the agreement with the retrieval findings as well as the wear model. Results: A wear patch of an appreciable and constant size could be measured in all five retrieved couples. The end point of revision was observed to occur when the wear progression reached a contact area corresponding to approximately 75% of the projected diameter of the ball. The wear volume was calculated from the geometry. The available literature describing the wear characteristics of retrieved bearings after successful clinical use showed good agreement with the calculated wear model. Conclusions: During the implant life of long-term successful metal-on-metal devices, a wear patch develops, as evident from retrieved failed devices. Failure often occurs through loosening, and the observed wear patch is similar in size for devices measured by us and for those described in the literature. We hypothesized that failure by loosening occurs through the accumulation of wear, which eventually leads to high friction within the bearing and increased torsional forces across the joint and its fixation. Clinical Relevance: This study will lead to a better understanding of long-term failure of first-generation metal-on-metal devices, which may lead to improvements in design and increased survival for more modern devices.
ACCESSION #
34045934

 

Related Articles

  • Tribological Considerations in Primary and Revision Metal-on-Metal Arthroplasty. Lee, Reginald; Essner, Aaron; Wang, Aiguo // Journal of Bone & Joint Surgery, American Volume;Aug2008 Supplement 3, Vol. 90-A, p118 

    Background: Metal-on-metal hip bearings undergo biphasic wear, starting with a short period of high wear (bedding-in) and followed by low steady-state wear. Bedding-in is the process by which the cup wears locally to conform to the geometry of the head. This process reduces the maximum contact...

  • Characterization of the Running-in Period in Total Hip Resurfacing Arthroplasty: An in Vivo and in Vitro Metal Ion Analysis. Heisel, Christian; Streich, Nikolaus; Krachler, Michael; Jakubowitz, Eike; Kretzer, J. Philippe // Journal of Bone & Joint Surgery, American Volume;Aug2008 Supplement 3, Vol. 90-A, p125 

    Background: Metal-on-metal total hip resurfacing arthroplasty is increasingly being performed in young and active patients. Preclinical in vitro testing of implants is usually performed with use of hip simulators, and the serum metal ion concentration is determined for the purpose of monitoring...

  • Wear Rate of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: A Randomized Controlled Trial. McCalden, Richard W.; MacDonald, Steven J.; Rorabeck, Cecil H.; Bourne, Robert B.; Chess, David G.; Charron, Kory D. // Journal of Bone & Joint Surgery, American Volume;Apr2009, Vol. 91-A Issue 4, p773 

    Background: Highly cross-linked polyethylene was introduced for clinical use in total hip arthroplasty with the expectation that it would exhibit less wear when compared with conventional polyethylene. The purpose of this study was to report the clinical and radiographic results, after a minimum...

  • Clinical digest. Trial proves apremilast is effective long-term treatment for psoriasis.  // Nursing Standard;10/10/2012, Vol. 27 Issue 6, p14 

    The article discusses research in the article "Efficacy of Apremilast in the Treatment of Moderate to Severe Psoriasis: A Randomised Controlled Trial" by K. Papp et al. which found that the drug apremilast is effective for the long term treatment of psoriasis.

  • Clinical digest. Evidence supports wider use of tranexamic acid in traumatic bleeding.  // Nursing Standard;10/10/2012, Vol. 27 Issue 6, p15 

    The article discusses research in the article "Effect of Tranexamic Acid on Mortality in Patients With Traumatic Bleeding: Prespecified Analysis of Data From Randomised Controlled Trial" by I. Roberts et al. which found that tranexamic acid is safe and effective in treating traumatic bleeding.

  • Clinical digest. Most people treated for schizophrenia experience no lasting improvements in health.  // Nursing Standard;4/18/2012, Vol. 26 Issue 33, p14 

    The article discusses research which was published in the article "Sustained Favourable Long-Term Outcome in the Treatment of Schizophrenia: A 3-Year Prospective Observational Study" by G Cuyun Carter et al. and found that most people treated for schizophrenia experience no lasting improvements...

  • PERSPECTIVE. Hee Kit Wong // Orthopedics Today;Jul2011, Vol. 31 Issue 7, p26 

    The author comments on the study by Miyako Suzuki wherein Suzuki found that, in determining whether using local bone graft is as effective as iliac crest bone graft in case of L4 degenerative spondylolisthesis, there are fusion rates of 90% and 85%, respectively, in single-level instrumented cases.

  • Clinical digest. Surgery for epilepsy can enhance patients' overall long-term quality of life.  // Nursing Standard;3/7/2012, Vol. 26 Issue 27, p18 

    The article discusses research which was reported in the article "Impact of Epilepsy Surgery on Seizure Control and Quality of Life: A 26-Year Follow-Up Study" by H. S. Mohammed et al and found that surgery for epilepsy can enhance patients’ overall long-term quality of life.

  • Emergency Brake Response Time After First Metatarsal Osteotomy. Holt, G.; Kay, M.; McGrory, R.; Kumar, C. S. // Journal of Bone & Joint Surgery, American Volume;Aug2008, Vol. 90-A Issue 8, p1660 

    Background: There is sparse information upon which to recommend a return to activity after foot surgery. The purpose of this study was to determine whether six weeks is sufficient time for the emergency brake response time to return to preoperative levels after a first metatarsal osteotomy for...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics