TITLE

Characterization of the Running-in Period in Total Hip Resurfacing Arthroplasty: An in Vivo and in Vitro Metal Ion Analysis

AUTHOR(S)
Heisel, Christian; Streich, Nikolaus; Krachler, Michael; Jakubowitz, Eike; Kretzer, J. Philippe
PUB. DATE
August 2008
SOURCE
Journal of Bone & Joint Surgery, American Volume;Aug2008 Supplement 3, Vol. 90-A, p125
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Metal-on-metal total hip resurfacing arthroplasty is increasingly being performed in young and active patients. Preclinical in vitro testing of implants is usually performed with use of hip simulators, and the serum metal ion concentration is determined for the purpose of monitoring the patients. The goal of this study was to characterize the early running-in period in vivo and in vitro by characterizing metal ion levels. Methods: A well-functioning total hip resurfacing prosthesis was implanted in fifteen consecutive patients, and the serum metal ion concentrations in these patients were then determined preoperatively and at intervals during the first postoperative year (at one, six, twelve, twenty-four, and fifty-two weeks). The number of walking cycles was measured with use of a computerized accelerometer in order to compare walking cycles to hip simulator cycles. In vitro, five similar components were investigated for 3 million cycles with use of a hip simulator. Serum samples were obtained at different time points, and wear was measured by quantifying wear particles and ions in the samples. All patient and simulation serum samples were analyzed with use of inductively coupled plasma-mass spectrometry. One simulator implant was investigated with use of scanning electron microscopy. Results: The serum chromium and cobalt levels of the patients continuously increased during the first six months and showed an insignificant decrease thereafter. The molybdenum concentration was unchanged compared with preoperative values. In contrast, the simulator measurements showed a different wear pattern with a high-wear running-in period and a low-wear steady-state phase. The running-in period was delayed by 300,000 cycles and lasted up to 1 million cycles. Scanning electron microscopic analysis showed a carbon-rich protein film predominantly in the early phases of simulation. Scratches were detected originating from pits filled with aluminum oxide and silicon oxide and from pulled-out carbides that were causing third-body wear. Conclusions: The simulator study allowed an exact characterization of the running-in period and showed a delayed onset of running-in wear. In contrast, the clinical data showed a slow increase in measured ion concentrations. These different wear patterns are probably due to the effects of distribution, accumulation, and excretion of particles and ions in vivo.
ACCESSION #
34045933

 

Related Articles

  • Tribological Considerations in Primary and Revision Metal-on-Metal Arthroplasty. Lee, Reginald; Essner, Aaron; Wang, Aiguo // Journal of Bone & Joint Surgery, American Volume;Aug2008 Supplement 3, Vol. 90-A, p118 

    Background: Metal-on-metal hip bearings undergo biphasic wear, starting with a short period of high wear (bedding-in) and followed by low steady-state wear. Bedding-in is the process by which the cup wears locally to conform to the geometry of the head. This process reduces the maximum contact...

  • Design Considerations and Life Prediction of Metal-on-Metal Bearings: The Effect of Clearance. Tuke, Michael A.; Scott, Gareth; Roques, Anne; Hu, Xiao Q.; Taylor, Andrew // Journal of Bone & Joint Surgery, American Volume;Aug2008 Supplement 3, Vol. 90-A, p134 

    Background: Clinical observations suggest that metal-on-metal arthroplasties that have been implanted for more than twenty years do fail. It is proposed that there are not two, but three distinct phases of wear life for any metal-on-metal implant system: bedding-in, steady state, and end point....

  • Cementing Techniques for Hip Resurfacing Arthroplasty: Development of a Laboratory Model. Bitsch, Rudi G.; Loidolt, Travis; Heisel, Christian; Schmalzried, Thomas P. // Journal of Bone & Joint Surgery, American Volume;Aug2008 Supplement 3, Vol. 90-A, p102 

    Background: Hip resurfacing is extremely technique-sensitive, yet scientific investigations into cementing techniques are lacking. In this study, we tested open-cell, reticulated, carbon-foam materials in comparison with paired human femoral heads to validate a laboratory cementing model for...

  • Wear Rate of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: A Randomized Controlled Trial. McCalden, Richard W.; MacDonald, Steven J.; Rorabeck, Cecil H.; Bourne, Robert B.; Chess, David G.; Charron, Kory D. // Journal of Bone & Joint Surgery, American Volume;Apr2009, Vol. 91-A Issue 4, p773 

    Background: Highly cross-linked polyethylene was introduced for clinical use in total hip arthroplasty with the expectation that it would exhibit less wear when compared with conventional polyethylene. The purpose of this study was to report the clinical and radiographic results, after a minimum...

  • Metal Ion Levels in the Blood of Patients After Hip Resurfacing: A Comparison Between Twenty- eight and Thirty- six-Millimeter-Head Metal-on-Metal Prostheses. Antoniou, John; Zukor, David J.; Mwale, Fackson; Minarik, William; Petit, Alain; Huk, Olga L. // Journal of Bone & Joint Surgery, American Volume;Aug2008 Supplement 3, Vol. 90-A, p142 

    Background: Metal ion toxicity, metal hypersensitivity, and metal carcinogenicity are causes for concern for patients with metal-on-metal hip replacements. Thus, understanding the biological fate of metal ions, and consequently their long-term systemic effects, is of great interest to patients...

  • The Responsiveness of the Liverpool Oral Rehabilitation Questionnaire (LORQ): A Pilot Study. Pace-Balzan, Adrian; Butterworth, Christopher; Lowe, Derek; Rogers, Simon N. // International Journal of Prosthodontics;2009, Vol. 22 Issue 5, p456 

    This study aimed to evaluate the responsiveness of denture patients to the Liverpool Oral Rehabilitation Questionnaire (LORQ). Changes in scores for 20 core items completed from 2000 to 2005 by 16 patients both before and after oral rehabilitation were assessed. The median age of respondents was...

  • Antithrombotic Therapies in Primary Angioplasty. De Luca, Giuseppe; Marino, Paolo // Drugs;2008, Vol. 68 Issue 16, p2325 

    Despite the improvement in outcome observed with primary angioplasty compared with thrombolysis, there is still room for improvement. Indeed, despite restoration of optimal epicardial flow in the vast majority of patients, suboptimal myocardial reperfusion is observed in a relatively large...

  • Imageless Navigation in Hip Resurfacing: Avoiding Component Malposition During the Surgeon Learning Curve. Romanowski, James R.; Swank, Michael L. // Journal of Bone & Joint Surgery, American Volume;Aug2008 Supplement 3, Vol. 90-A, p65 

    Background: Studies suggest that hip arthroplasty procedures performed in specialty hospitals or by physicians in practices with a high surgical volume are associated with a decreased rate of adverse outcomes related to component malpositioning. Little is known, however, about the influence of...

  • Have Contemporary Hip Resurfacing Designs Reached Maturity? A Review. Ong, Kevin L.; Manley, Michael T.; Kurtz, Steven M. // Journal of Bone & Joint Surgery, American Volume;Aug2008 Supplement 3, Vol. 90-A, p81 

    Background: The increasing prevalence of hip replacements in young patients is expected to fuel the demand for hip resurfacing arthroplasty. Patient selection, surgical technique, and implant design can influence the clinical outcomes for these patients. In this review, we discuss whether...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics