Modes of Failure of Osteonics Constrained Tripolar Implants: A Retrospective Analysis of Forty-three Failed Implants

Olivier Guyen; David G. Lewallen; Miguel E. Cabanela
July 2008
Journal of Bone & Joint Surgery, American Volume;Jul2008, Vol. 90-A Issue 7, p1553
Academic Journal
Background: The Osteonics constrained tripolar implant has been one of the most commonly used options to manage recurrent instability after total hip arthroplasty. Mechanical failures were expected and have been reported. The purpose of this retrospective review was to identify the observed modes of failure of this device. Methods: Forty-three failed Osteonics constrained tripolar implants were revised at our institution between September 1997 and April 2005. All revisions related to the constrained acetabular component only were considered as failures. All of the devices had been inserted for recurrent or intraoperative instability during revision procedures. Seven different methods of implantation were used. Operative reports and radiographs were reviewed to identify the modes of failure. Results: The average time to failure of the forty-three implants was 28.4 months. A total of five modes of failure were observed: failure at the bone-implant interface (type I), which occurred in eleven hips; failure at the mechanisms holding the constrained liner to the metal shell (type II), in six hips; failure of the retaining mechanism of the bipolar component (type III), in ten hips; dislocation of the prosthetic head at the inner bearing of the bipolar component (type IV), in three hips; and infection (type V), in twelve hips. The mode of failure remained unknown in one hip that had been revised at another institution. Conclusions: The Osteonics constrained tripolar total hip arthroplasty implant is a complex device involving many parts. We showed that failure of this device can occur at most of its interfaces. It would therefore appear logical to limit its application to salvage situations.


Related Articles

  • Look to constrained liners to treat patients with chronic hip dislocation after THA. Brockenbrough, Gina // Orthopedics Today;Oct2008, Vol. 28 Issue 10, p9 

    The article looks at using constrained total hip designs to treat dislocation in total hip arthroplasty. Mathias P.G. Bostrom, MD, noted the success rates using the Osteonics device but suggested options such as using Durasul, a Zimmer design which has an improved range of motion. Bostrom...

  • Revision total hip arthroplasty using the Zweymuller femoral stem. Matthew Oetgen; Michael Huo // Journal of Orthopaedics & Traumatology;Jun2008, Vol. 9 Issue 2, p57 

    Abstract Background  A variety of femoral stem designs have been reported to be successful in revision total hip arthroplasty without consensus as to optimal design. We evaluated the clinical and radiographic outcomes in a consecutive series of femoral revisions using a wedge-shape,...

  • Revision of failed hip resurfacing to total hip arthroplasty rapidly relieves pain and improves function in the early post operative period. Sandiford, Nemandra A.; Muirhead-Allwood, Sarah K.; Skinner, John A. // Journal of Orthopaedic Surgery & Research;2010, Vol. 5, p88 

    We reviewed the results of 25 consecutive patients who underwent revision of a hip resurfacing prosthesis to a total hip replacement. Revisions were performed for recurrent pain and effusion, infection and proximal femoral fractures. Both components were revised in 20 cases. There were 12 male...

  • Strategies for head and inlay exchange in revision hip arthroplasty. Pospischill, Martin; Knahr, Karl // International Orthopaedics;Feb2011, Vol. 35 Issue 2, p261 

    Due to the increasing number of total hip arthroplasties performed during the last three decades and the limited long-term survival, mainly because of wear, the number of revisions has increased during the last two years. If the implant itself is still considered to be stable, only head and...

  • Jumbo cups for revision of acetabular defects after total hip arthroplasty: a retrospective review of a case series. Wedemeyer, Christian; Neuerburg, Carl; Heep, Hansjoerg; Von Knoch, Fabian; Von Knoch, Marius; Löer, Franz; Saxler, Guido // Archives of Orthopaedic & Trauma Surgery;Jun2008, Vol. 128 Issue 6, p545 

    The treatment of acetabular bone defects presents a great challenge in revision total hip arthroplasty (THA). The purpose of this study was to evaluate the clinical and radiological outcome of revision THA using jumbo cups for acetabular reconstruction after applying the bone-grafting technique....

  • The Epidemiology of Revision Total Hip Arthroplasty in the United States. Bozic, Kevin J.; Kurtz, Steven M.; Lau, Edmund; Kevin Ong; Vail, Thomas P.; Berry, Daniel J. // Journal of Bone & Joint Surgery, American Volume;Jan2009, Vol. 91-A Issue 1, p128 

    Background: Understanding the causes of failure and the types of revision total hip arthroplasty performed is essential for guiding research, implant design, clinical decision-making, and health-care policy. The purpose of the present study was to evaluate the mechanisms of failure and the types...

  • THE USE OF STRUCTURAL DISTAL FEMORAL ALLOGRAFTS FOR ACETABULAR RECONSTRUCTION. Sporer, Scott M.; O'Rourke, Michael; Chong, Paul; Paprosky, Wayne G. // Journal of Bone & Joint Surgery, American Volume;Apr2005, Vol. 87-A Issue 4, p760 

    Background: Acetabular fixation during revision total hip arthroplasty in patients who have a nonsupportive superior dome and proximal migration of tile acetabular component (a Paprosky Type-IIIa defect) cannot be achieved reliably with use of a hemispherical porous-coated component alone. The...

  • REVISION OF THE ACETABULAR COMPONENT WITHOUT CEMENT AFTER TOTAL HIP ARTHROPLASTY. Della Valle, Craig J.; Shuaipaj, Tasin; Berger, Richard A.; Rosenberg, Aaron G.; Shott, Susan; Jacobs, Joshua J.; Galante, Jorge O. // Journal of Bone & Joint Surgery, American Volume;Aug2005, Vol. 87-A Issue 8, p1795 

    Abstract: We previously reported our results at a minimum of three and seven years after use of a porous-coated acetabular metal shell in a consecutive series of 138 revision total hip arthroplasties. The current report presents the longer-term outcomes of these procedures, at fifteen to...

  • Revision of the Birmingham Hip Resurfacing cup: technical notes and the use of a novel technique to overcome unique problems. SANDIFORD, N. A.; KABIR, C.; MUIRHEAD-ALLWOOD, S. K.; SKINNER, J.; NUTHALL, T. // Hip International;Jul-Sep2008, Vol. 18 Issue 3, p220 

    The number of hip resurfacing procedures performed in the United Kingdom has doubled in the last four years reflecting its popularity among orthopaedic surgeons. Of the available options the Birmingham Hip Resurfacing (BHR) prosthesis has been the most popular choice in this country. Despite...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library