TITLE

Radiographic Assessment of the Thickness Lost from Polyethylene Tibial Inserts That Had Been Sterilized Differently

AUTHOR(S)
Collier, Matthew B.; Engh, Jr., C. Anderson; Hatten, Kyle M.; Ginn, Stuart D.; Sheils, Todd M.; Engh, Gerard A.
PUB. DATE
July 2008
SOURCE
Journal of Bone & Joint Surgery, American Volume;Jul2008, Vol. 90-A Issue 7, p1543
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Archived serial radiographs of knee replacements provide indirect evidence of the clinical performance of ultra-high molecular weight polyethylene tibial bearings. Our purpose was to determine the loss of thickness in polyethylene tibial inserts that were of the same design but had been sterilized differently. Methods: Four hundred and sixteen knees with an Anatomic Modular Knee primary total knee replacement had five to eighteen years of follow-up and a posterior cruciate ligament-retaining polyethylene tibial insert that had been sterilized with either gamma radiation in air (from 1987 to 1993) or gamma radiation in an inert gas (from 1993 to 1995), or by means of a nonirradiation gas-plasma method (from 1995 to 2001). Readings were taken from 1975 weight-bearing anteroposterior radiographs of the knee on which the top surface of the metal tibial tray had nearly projected as a line. In each tibiofemoral compartment, loss of polyethylene thickness was calculated as the standard thickness of the insert minus the measured magnification-corrected thickness. For each sterilization method, thickness loss was plotted versus the corresponding follow-up time, and a mixed linear regression model was used to quantify the change in thickness overtime. Multiple linear regression analysis was used to determine whether loss of thickness was associated with implant factors, patient variables, and early postoperative limb alignment. Results: According to the mixed model regression coefficients, loss of medial compartment thickness was greatest for inserts that had been sterilized with gamma radiation in air (0.15 mm/yr), least for those sterilized with gamma radiation in an inert gas (0.02 mm/yr), and of an intermediate magnitude for those sterilized with a nonirradiation method (0.06 mm/year); loss of lateral compartment thickness ranged from 0.03 to 0.06 mm/yr. Notably, no insert irradiated in an inert gas showed a loss of thickness of >1 mm, and no nonirradiated insert showed a loss of >2 mm. Loss of medial compartment thickness in inserts sterilized with radiation in air increased significantly with a greater polyethylene shelf age, lesser patient age, and more varus alignment of the limb in the early postoperative period (p < 0.01). Conclusions: In this total knee design, tibial polyethylene performance improved markedly after discontinuation of the gamma radiation in air sterilization technique. Future concerns are that bearings sterilized with radiation in an inert gas may oxidize in vivo and develop fatigue wear because of free radicals generated during sterilization with radiation and that nonirradiated bearings may undergo greater losses in thickness from routine burnishing since they lack the cross-linking that accompanies sterilization with radiation.
ACCESSION #
33434229

 

Related Articles

  • Effect of limb rotation on radiographic alignment in total knee arthroplasties. Radtke, Kerstin; Becher, Christoph; Noll, Yvonne; Ostermeier, Sven // Archives of Orthopaedic & Trauma Surgery;Apr2010, Vol. 130 Issue 4, p451 

    Even in a well-aligned total knee arthroplasty (TKA), limb rotation at the time of radiographic assessment will alter the measurement of alignment. This could influence the radiographic outcome of TKA. The purpose of this study was to evaluate the effect of limb rotation on radiographic...

  • Use of Porous Tantalum Metaphyseal Cones for Severe Tibial Bone Loss During Revision Total Knee Replacement. Meneghini, R. Michael; Lewallen, David G.; Hanssen, Arlen D. // Journal of Bone & Joint Surgery, American Volume;Jan2008, Vol. 90-A Issue 1, p78 

    Background: The best treatment method for large tibial bone defects during revision knee replacement has not been established. The purpose of this study was to determine the initial results obtained with a unique reconstructive implant, the porous tantalum metaphyseal cone, designed as an...

  • The Need for Alternative Bearings. Laskin, Richard S. // Orthopedics;Sep2003, Vol. 26 Issue 9, p966 

    The article discusses the need to find alternative bearing surfaces in total knee arthroplasty. It states how polyethylene wear is a continuing problem. It discusses studies done in changing the properties of polyethylene itself. It states that it is useless to try improving polyethylene without...

  • Do Patient-specific Guides Improve Coronal Alignment in Total Knee Arthroplasty? Nunley, Ryan; Ellison, Bradley; Zhu, Jinjun; Ruh, Erin; Howell, Stephen; Barrack, Robert // Clinical Orthopaedics & Related Research;Mar2012, Vol. 470 Issue 3, p895 

    Background: Coronal alignment may impact clinical outcome and survivorship in TKA. Patient-specific instrumentation has been developed to restore mechanical or kinematic axis and potentially reduce component malpositioning. Although it is clear these instruments add cost, it is unclear whether...

  • Improving Tibial Component Coronal Alignment During Total Knee Arthroplasty with Use of a Tibial Planing Device. Patil, Shantanu; D'Lima, Darryl D.; Fait, James M.; Colwell Jr., Clifford W. // Journal of Bone & Joint Surgery, American Volume;Feb2007, Vol. 89-A Issue 2, p381 

    Background: The outcomes of knee arthroplasty have been shown to be affected by component alignment. Intramedullary and extramedullary alignment instrumentation are fairly effective for achieving the desired mean tibial component coronal alignment. However, there are outliers representing >3°...

  • The Knee, Not the Brain, Defines Quality of Life. Sorbie, Charles // Orthopedics;Jan2006, Vol. 29 Issue 1, p19 

    Focuses on a study which revealed that total knee arthroplasty (TKA) offers excellent pain relief to patients by does not always improve knee joint motion. Effect of the limitation of motion after surgery on the quality of life of patients; Significant results of the study.

  • Asymmetrical total knee arthroplasty does not improve patella tracking: a study without patella resurfacing. Barink, Marco; Meijerink, Huub; Verdonschot, Nico; Kampen, Albert; Waal Malefijt, Maarten // Knee Surgery, Sports Traumatology, Arthroscopy;Feb2007, Vol. 15 Issue 2, p184 

    It is often suggested that patella tracking after total knee arthroplasty (TKA) with an asymmetrical patella groove is more physiological than with a symmetrical patella groove. Therefore, this study tried to address two questions: what is the effect of TKA on patella tracking, and is patella...

  • Weight Bearing Capability Of An Antibiotic Loaded Pre-Formed Articulated Knee Spacer: A Case Report. Schulz, Arndt P.; Jñ/4rgens,, Christian; Faschingbauer, Maximilian // Internet Journal of Orthopedic Surgery;2007, Vol. 4 Issue 1, p12 

    One of the solutions for the problem of infected total knee arthroplasty is a two-staged procedure with the use of an antibiotic impregnated acrylic articulated spacer. Such an implant is commercially available on the German market. It has been thoroughly tested; directions supplied with this...

  • Anterior knee pain following total knee replacement caused by isolated Paget's disease of patella. Gupta, Rohit; Canty, Steve; Ryan, William G. // Internet Journal of Orthopedic Surgery;2008, Vol. 9 Issue 2, p7 

    We as a routine do not resurface the patella during a total knee replacement in our hospital. I present below a case where we had to do so because the patient developed anterior knee pain following a total knee replacement that was diagnosed as arising from isolated Paget's disease of the...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics