TITLE

Impact of Hospital Volume on the Economic Value of Computer Navigation for Total Knee Replacement

AUTHOR(S)
Slover, James D.; Tosteson, Anna N. A.; Bozic, Kevin J.; Rubash, Harry E.; Malchau, Henrik
PUB. DATE
July 2008
SOURCE
Journal of Bone & Joint Surgery, American Volume;Jul2008, Vol. 90-A Issue 7, p1492
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: An aim of the use of computer navigation is to reduce rates of revisions of total knee replacements by improving the alignment achieved at the surgery. However, the decision to adopt this technology may be difficult for some centers, especially low-volume centers, where the cost of purchasing this equipment may be high. The purpose of this study was to examine the impact of hospital volume on the cost-effectiveness of this new technology in order to determine its feasibility and the level of evidence that should be sought prior to its adoption. Methods: A Markov decision model was used to evaluate the impact of hospital volume on the cost-effectiveness of computer-assisted knee arthroplasty in a theoretical cohort of sixty-five-year-old patients with end-stage arthritis of the knee to coincide with the peak incidence of knee arthroplasty in the United States. Results: Computer-assisted surgery becomes less cost-effective as the annual hospital volume decreases, as the cost of the navigation increases, and as the impact on revision rates decreases. Centers at which 250, 150, and twenty-five computer-navigated total knee arthroplasties are performed per year will require a reduction of the annual revision rate of 2%, 2.5%, and 13%, respectively, per year over a twenty-year period for computer navigation to be cost-effective. Conclusions: Computer navigation is less likely to be a cost-effective investment in health-care improvement in centers with a low volume of joint replacements, where its benefit is most likely to be realized. However, it may be a cost-effective technology for centers with a higher volume of joint replacements, where the decrease in the rate of knee revision needed to make the investment cost-effective is modest, if improvements in revision rates with the use of this technology can be realized.
ACCESSION #
33434223

 

Related Articles

  • THE FUNCTIONAL OUTCOMES OF TOTAL KNEE ARTHROPLASTY. Kane, Robert L.; Saleh, Khaled J.; Wilt, Timothy J.; Bershadsky, Boris // Journal of Bone & Joint Surgery, American Volume;Aug2005, Vol. 87-A Issue 8, p1719 

    Background: As an elective procedure, total knee arthroplasty is under scrutiny to evaluate its cost-effectiveness. In this review, we examined the available literature on total knee arthroplasty to assess the evidence regarding factors associated with better functional outcomes. Methods: A...

  • MIS: Why mess with excellence? Barrack, Robert L. // Orthopedics Today;Jan2008, Vol. 28 Issue 1, p62 

    The author offers opinion about minimally invasive total knee arthroplasty (TKA). A common notion of patients about MIS knee is that they are having an arthroscopy. One perceived advantage of this procedure is that in three months, it might be better than traditional TKA. A study that appeared...

  • Two-stage revision TKA shows good survival at 10 years mean follow-up. Piechocki, Michael // Orthopaedics Today/International Edition;May/Jun2008, Vol. 11 Issue 3, p7 

    The article reports that performing two-stage revision for infected primary total knee arthroplasty (TKA) shows good survival at 10 years mean follow-up, according to a study conducted by Mirco Pietri and colleagues. Of the 45 low-virulence and 63 high-virulence organisms isolated in patients,...

  • Resurfacing knee arthroplasty in patients with allergic sensitivity to metals. Pellengahr, C.; Mayer, W.; Maier, M.; Müller, P. E.; Schulz, C.; Dürr, H. R.; Trouillier, H.; Steinborn, M.; Jansson, V.; Refior, H. J. // Archives of Orthopaedic & Trauma Surgery;May2003, Vol. 123 Issue 4, p139 

    Background. The problem of metal sensitivity (Ni, Cr, and Co) in arthroplasty is still unsolved. To prevent the risk of allergy in cases with proved metal allergy in an epicutaneous test, a Natural Knee total knee arthroplasty, made totally from titanium (Ti-6Al-4V) and polyethylene, can be...

  • A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty. Richter, Berna I.; Ostermeier, Sven; Turger, Anke; Denkena, Berend; Hurschler, Christof // BioMedical Engineering OnLine;2010, Vol. 9, p24 

    Background: Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc...

  • An alternative method to create extramedullary references in total knee arthroplasty. Seo, Jai-Gon; Moon, Young-Wan; Park, Sang-Hoon; Shim, Jae-Woo; Kim, Sang-Min // Knee Surgery, Sports Traumatology, Arthroscopy;Jul2012, Vol. 20 Issue 7, p1339 

    Purpose: Historically, extramedullary techniques have focused on finding the femoral head center and referred mainly to the anterosuperior iliac spine (the FHC method) in total knee arthroplasty (TKA). The purpose of this study was to evaluate a new extramedullary alignment system that uses...

  • Bone mineral density changes of the proximal tibia after revision total knee arthroplasty. A randomised study with the use of porous tantalum metaphyseal cones. Jensen, Claus; Petersen, Michael; Schrøder, Henrik; Lund, Bjarne // International Orthopaedics;Sep2012, Vol. 36 Issue 9, p1857 

    Purpose: Forty patients were enrolled in a prospective randomised study using conventional method or 'Trabecular Metal Cone' (TM Cone) (Zimmer inc., Warsaw, USA) for reconstruction of bone loss of the proximal tibia during revision total knee arthroplasty (rTKA). The aim was to evaluate changes...

  • Sagittal placement of the femoral component in total knee arthroplasty predicts knee flexion contracture at one-year follow-up. Lustig, Sebastien; Scholes, Corey; Stegeman, Tim; Oussedik, Sam; Coolican, Myles; Parker, David // International Orthopaedics;Sep2012, Vol. 36 Issue 9, p1835 

    Purpose: Flexion contracture has been shown to impair function and reduce satisfaction following total knee arthroplasty (TKA). The aim of this study was to identify modifiable intra-operative variables that predict post-TKA knee extension. Methods: Data was collected prospectively on 95...

  • Experiences with computer navigated total knee arthroplasty. Bejek, Zoltán; Sólyom, László; Szendrõi, Miklós // International Orthopaedics;Oct2007, Vol. 31 Issue 5, p617 

    The successful outcome of total knee arthroplasty (TKA) is very much dependent on precise positioning of the components. Inaccuracy may result in complaints as well as in early mechanical failure. Between March 2003 and September 2005, 69 TKA procedures were performed by the computer navigated...