TITLE

Anion exchange silica monolith for capillary liquid chromatography

AUTHOR(S)
Jaafar, Jafariah; Watanabe, Yuta; Ikegami, Tohru; Miyamoto, Kosuke; Tanaka, Nobuo
PUB. DATE
August 2008
SOURCE
Analytical & Bioanalytical Chemistry;Aug2008, Vol. 391 Issue 7, p2551
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
An anion exchange monolithic silica capillary column was prepared by surface modification of a hybrid monolithic silica capillary column prepared from a mixture of tetramethoxysilane (TMOS) and methyltrimethoxysilane (MTMS). The surface modification was carried out by on-column copolymerization of N-[3-(dimethylamino)propyl]acrylamide methyl chloride-quaternary salt (DMAPAA-Q) with 3-methacryloxypropyl moieties bonded as an anchor to the silica surface to form a strong anion exchange stationary phase. The columns were examined for their performance in liquid chromatography (LC) and capillary electrochromatography (CEC) separations of common anions. The ions were separated using 50 mM phosphate buffer at pH 6.6. Evaluation by LC produced an average of 30,000 theoretical plates (33 cm column length) for the inorganic anions and nucleotides. Evaluation by CEC, using the same buffer, produced enhanced chromatographic performance of up to ca. 90,000 theoretical plates and a theoretical plate height of ca. 4 μm. Although reduced efficiency was observed for inorganic anions that were retained a long time, the results of this study highlight the potential utility of the DMAPAA-Q stationary phase for anion separations. [Figure not available: see fulltext.]
ACCESSION #
33372829

 

Related Articles

  • Studies on the feasibility of using crystalline silicotitanates for the separation of cesium-137 from fast reactor high-level liquid waste. Venkatesan, K. A.; Sukumaran, V.; Antony, M. P.; Srinivasan, T. G. // Journal of Radioanalytical & Nuclear Chemistry;Apr2009, Vol. 280 Issue 1, p129 

    The commercially available crystalline silicotitanate inorganic ion exchanger, IONSIV IE-911, and its parent precursor, TAM-5, have been evaluated for the removal of 137Cs from nitric acid medium and simulated high-level liquid waste. The distribution coefficient ( K d) of cesium decreased with...

  • Effect of steam and carbon dioxide pretreatments on methane decomposition and carbon gasification over doped-ceria supported nickel catalyst. Ta-Jen Huang; Tien-Chun Yu // Catalysis Letters;Jun2005, Vol. 102 Issue 3/4, p175 

    Effects of steam (H2O) and carbon dioxide (CO2) pretreatments on methane (CH4) decomposition and carbon gasification over doped-ceria supported nickel catalysts have been studied from 400 to 500 °C. The doped ceria employed were gadolinia-doped ceria and samaria-doped ceria. Results indicate...

  • Ion-exchange behavior of stannic selenoiodate and stannic selenosilicate: analytical application of stannic selenoiodate. Nabi, Syed Ashfaq; Khan, Amjad Mumtaz // Analytical & Bioanalytical Chemistry;Jun2005, Vol. 382 Issue 4, p1163 

    Two new inorganic ion exchangers, stannic selenoiodate and stannic selenosilicate have been synthesized. The ion-exchange capacity of stannic selenoiodate and stannic selenosilicate for K+ was found to be 1.84 and 1.23 meq g−1, respectively. pH titration studies reveal monofunctional and...

  • Properties and Uses of Sodium Titanates and Peroxotitanates. Hobbs, D. T. // Journal of the South Carolina Academy of Science;2011, Vol. 9 Issue 1, p20 

    Sodium titanates and peroxotitanates are inorganic ion-exchangers that exhibit strong affinities for a wide range of metals. These materials serve as effective ion-exchangers in strongly alkaline, neutral, and weakly acidic solutions. One of the sodium titanates, referred to as monosodium...

  • Synthesis and thermal stability of some inorganic ion exchangers based on silicon and tin. Sharma, S.; Varshney, K.; Mojumdar, S. // Journal of Thermal Analysis & Calorimetry;Jun2012, Vol. 108 Issue 3, p843 

    A number of silicon-based inorganic ion exchangers were synthesized under different conditions of preparation. The original and regenerated ion exchange capacities (IECs) were determined. Thermal stability of these materials was investigated in the temperature range of 40-800 °C. The...

  • The Making of a Column. Hinshaw, John V. // LC-GC Europe;Feb2006, Vol. 19 Issue 2, p93 

    The article reports on the manufacturing of fused-silica capillary gas chromatography (GC) columns. Fused-silica columns deliver general and application-specific separations with higher mechanical stability and lower bleed levels. Sodium, borosilicate and fused-silica are the three basic types...

  • Capillary Tubing: Uniquely Shaped Internal and External Geometries. Macomber, Joe; Stasiak, Drew // LC-GC North America;Feb2008 Applications Notebook, Vol. 26, p63 

    Synthetic fused silica capillary tubing is commonly used in applications where round geometries are of critical importance. However, there are times when round surfaces complicate analytical efforts. This application note discusses capillary with unique geometries and related design considerations.

  • The Effect of Cation Type on Lignosulfonate Dispersant Performance in Disperse Dye Systems. Dilling, Peter // Textile Chemist & Colorist;May88, Vol. 20 Issue 5, p17 

    New demands on dispersant performance in disperse dye systems require a close examination of dispersant chemistry. The impact of various cations on a lignosulfonate dispersant's performance was investigated. Properties of sodium and ammonium lignosulfonate salts were compared with lignosulfonate...

  • Methanesuiphonic acid loss during ice-core storage: recommendations based on a new diffusion coefficient. Roberts, Jason L.; Van Ommen, Tas D.; Curran, Mark A.J.; Vance, Tessa R. // Journal of Glaciology;2009, Vol. 55 Issue 193, p784 

    The article presents a study which examines the new diffusion coefficient for minimizing the loss of methanesulphonic acid (MSA) from two stored ice cores DSS43A and DSS99 collected from Law Dome in East Antarctic, Antarctica. It mentions the use of ICS3000 microbore ion chromatograph to analyze...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library