TITLE

Study of electron behavior in a pulsed ion sheath

AUTHOR(S)
Kar, S.; Mukherjee, S.
PUB. DATE
June 2008
SOURCE
Physics of Plasmas;Jun2008, Vol. 15 Issue 6, p063504
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
In many plasma processing applications, like plasma immersion ion implantation (PIII), the substrate is immersed in low pressure plasma and is biased with negative voltage pulses. In typical PIII, the pulse duration is much larger than the ion response time, and hence the ion matrix sheath expands and ion implantation happens on the biased substrate. It is assumed that for pulse duration shorter than ion response times, the ions remain stationary and electrons are repelled by the negative bias. In the present investigation, the negative pulse duration is varied between ion and electron plasma response times; so as to study the electron behavior assuming ions are stationary. The results indicate that the electrons that are lost to the walls come from the ion matrix sheath and probably from the bulk plasma as well. The pulse duration, when it is less than the ion response time, plays a crucial role in determining the number of electrons lost to the walls.
ACCESSION #
32970364

 

Related Articles

  • Ion depletion effects in sheath dynamics during plasma immersion ion implantation—models and data. Kellerman, Peter L.; Qin, Shu; Bradley, Michael P.; Saadatmand, Kourosh // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p837 

    In plasma immersion ion implantation, the wafer is negatively pulsed while immersed in a dc ambient plasma. During this high voltage pulse, the sheath expands, and plasma ions are accelerated to the wafer. The essential character of this plasma sheath expansion can be described by a simple...

  • Sheath criterion and Sagdeev potential for both electronegative and electropositive plasmas. Alterkop, B. // Journal of Applied Physics;Dec2008, Vol. 104 Issue 12, p123301 

    The sheath criterion was considered for electronegative as well as electropositive plasma in contact with a material boundary that is either more negative than the plasma space potential or more positive than the space potential. A fluid model accounted for the inertia and pressures of all the...

  • Modelling of dusty plasmas: A+M data needs. Goedheer, W. J.; De Bleecker, K. // AIP Conference Proceedings;2005, Vol. 771 Issue 1, p118 

    Processing plasmas often produce clusters, ranging in size from a few nanometer up to micrometers. Due to their negative charge, clusters are confined by the sheath electric fields until their mass enables gravity to pull them out of the discharge. Examples are discharges in SiH4 or C2H2....

  • Sheath and presheath in ion-ion plasmas via particle-in-cell simulation. Meige, A.; Leray, G.; Raimbault, J.-L.; Chabert, P. // Applied Physics Letters;2/11/2008, Vol. 92 Issue 6, p061501 

    A full particle-in-cell simulation is developed to investigate electron-free plasmas constituted of positive and negative ions under the influence of a dc bias voltage. It is shown that high-voltage sheaths following the classical Child-law sheaths form within a few microseconds (which...

  • Ion focusing and interaction potential for spherical and rodlike obstacles in a supersonic plasma flow: numerical simulations. Miloch, W. J.; Pécseli, H. L.; Trulsen, J.; Vladimirov, S. V. // AIP Conference Proceedings;9/7/2008, Vol. 1041 Issue 1, p287 

    The parameter dependence of the ion focus [1, 2] behind perfectly conducting or alternatively perfectly insulating spherical grains for different electron to ion temperature ratios is studied. For elongated, insulating dust grains we study the potential and plasma density wakes in drifting...

  • Probe measurements in a nonstationary plasma. Bliokh, Yu. P.; Brodsky, Yu. L.; Chashka, Kh. B.; Felsteiner, J.; Slutsker, Ya. Z. // Journal of Applied Physics;Mar2008, Vol. 103 Issue 5, p053303 

    Single and double probes are simple and common tools for plasma measurements. In the case of nonstationary plasmas, the values of the plasma density obtained with these tools may differ significantly from the correct values measured, e.g., by microwave methods. The reason for such discrepancy...

  • Measurement of expanding plasma sheath from a target biased by a negative pulse with a fast rise time. Kim, Gon-Ho; Kim, Young-Woo; Han, Seunghee; Uhm, Han-Sup; Cho, Jeonghee; Jung, Min Joong; Hong, Munpyo // Journal of Applied Physics;2/1/2003, Vol. 93 Issue 3, p1384 

    The pulse rise time effect on sheath size is investigated. Experiments are carried out on a planar target biased by a negative pulse with a fast rise time in a plasma source ion implantation (PSII) system. The fast rise time of the pulse provides that the speed of sheath expansion is larger than...

  • Instrumentation for plasma immersion ion implantation. López-Callejas, R.; Valencia-Alvarado, R.; Muñoz-Castro, A. E.; Godoy-Cabrera, O. G.; Tapia-Fabela, J. L. // Review of Scientific Instruments;Dec2002, Vol. 73 Issue 12, p4277 

    Plasma immersion ion implantation (PIII) has proved to be a good method to implant ions into materials in order to modify their surface properties. In this article, we describe the design and construction of a small and low cost PIII device. The instrumentation consists of: (i) a simple plasma...

  • Secondary electron enhanced discharges in plasma source ion implantation. Cluggish, B. P.; Munson, C. P. // Journal of Applied Physics;12/1/1998, Vol. 84 Issue 11, p5945 

    Presents the measurements of a plasma discharge enhanced by secondary electrons during plasma source ion implantation. Description of the apparatus; Simulation; Experiments on hollow cathode instability and beam-plasma instability; Discussion.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics