TITLE

Preface

AUTHOR(S)
Sykes, Pamela; Mitchel, Ron; Higson, Donald
PUB. DATE
October 2007
SOURCE
Dose-Response;2007, Vol. 5 Issue 4, p256
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A preface for the October 2007 issue of the "Dose-Response" is presented.
ACCESSION #
32523432

 

Related Articles

  • STATISTICAL CHALLENGES IN EVALUATING DOSE-RESPONSE USING EPIDEMIOLOGICAL DATA. Mundt, Kenneth A. // Dose-Response;2005, Vol. 3 Issue 4, p453 

    The article discusses various reports published within the issue, including one by Kenny S. Crump on the impact of random error on the assessment of the shape of the dose-response and another by Edwin van Wijngaarden on graphical approach for uncovering dose-responses.

  • Lose-Dose Abdominal CT for Appendicitis. Kuritzky, Louis // Internal Medicine Alert;6/15/2012 Supplement, p87 

    The article informs that the use of low-dose abdominal computed tomography (AB-CT) scan to diagnose appendicitis is as effective as high-dose AB-CT.

  • Measurement of parameters for the quality control of X-ray units by using PIN diodes and a personal computer. Ramı´rez, F.; Gayta´n, E.; Mercado, I.; Estrada, M.; Cerdeira, A. // AIP Conference Proceedings;2000, Vol. 538 Issue 1, p196 

    The design of a new system for the measurement of the main parameters of X-ray units used in medicine is presented. The system measures automatically the exposure time, high voltage applied, waveform of the detected signal, exposure ratio and the total exposure (dose). The X-ray detectors...

  • Evolution of dose distribution calculations in brachytherapy. Rodrı´guez-Villafuerte, M. // AIP Conference Proceedings;2000, Vol. 538 Issue 1, p149 

    In this report the evolution of dose distribution calculations is revised in detail, considering the simplest case (a point source in free space) and the more complex situation of a real encapsulated line source embedded in a scattering medium. The most recent formalism to perform the dosimetry...

  • Monte Carlo dosimetry in HDR brachytherapy. Martı´nez-Da´valos, A. // AIP Conference Proceedings;2000, Vol. 538 Issue 1, p128 

    A Monte Carlo simulation of an encapsulated [sup 192]Ir source for high dose rate (HDR) prostate brachytherapy is presented. Basic dosimetric quantities related to this source are derived from the simulation data following the AAPM Task Group 43 formalism, including dose rate constant, source...

  • Patient-Circumference-Adapted Dose Regulation in Body Computed Tomography. A Practical and Flexible Formula. Nyman, U.; Ahl, T. L.; Kristiansson, M.; Nilsson, L.; Wettemark, S. // Acta Radiologica;Jul2005, Vol. 46 Issue 4, p396 

    Purpose: To illustrate that the attenuation formula based on monochromatic radiation in homogeneous objects may be used for dose regulation in body computed tomography (CT) based on patient circumference and using a simple cloth measuring tape. Material and Methods: Based on the attenuation...

  • PATIENT SKIN DOSE ASSESSMENT DURING CT-GUIDED INTERVENTIONAL PROCEDURES. Tsapaki, V.; Triantopoulou, C.; Maniatis, P.; Kottou, S.; Tsalafoutas, J.; Papailiou, J. // Radiation Protection Dosimetry;2008 Special Issue, Vol. 129 Issue 1-3, p29 

    The purpose of this study was to investigate patient skin doses in the most frequent computed tomography-guided interventional radiology procedures. The study includes 14 abdominal biopsies and 15 radiofrequency (RF) ablations. Patient skin dose was assessed by slow verification films. The...

  • EFFECTS OF RADIOLOGISTS' SKILL AND EXPERIENCE ON PATIENT DOSES IN INTERVENTIONAL EXAMINATIONS. Bor, Dogan; Sancak, Tanzer; Toklu, Turkay; Olgar, Turan; Ener, Selmin // Radiation Protection Dosimetry;2008 Special Issue, Vol. 129 Issue 1-3, p32 

    In this study, effects of radiologists' skill and experience on patient doses were investigated. Dose-area product and entrance surface doses of two groups of patients, one examined by a number of junior radiologists and another one by a senior radiologist, have been compared for the diagnostic...

  • OCCUPATIONAL RADIATION DOSES IN INTERVENTIONAL RADIOLOGY: SIMULATIONS. Siiskonen, T.; Tapiovaara, M.; Kosunen, A.; 6 Lehtinen, M.; Vartiainen, E. // Radiation Protection Dosimetry;2008 Special Issue, Vol. 129 Issue 1-3, p36 

    In interventional radiology, occupational radiation doses can be high. Therefore, many authors have established conversion coefficients from the dose-area product data or from the personal dosemeter reading to the effective dose of the radiologist. These conversion coefficients are studied also...