TITLE

A new liquid chromatographic method for routine determination of oxytetracycline marker residue in the edible tissues of farm animals

AUTHOR(S)
Fletouris, Dimitrios J.; Papapanagiotou, Elias P.
PUB. DATE
June 2008
SOURCE
Analytical & Bioanalytical Chemistry;Jun2008, Vol. 391 Issue 4, p1189
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A simple, rapid, and specific ion-pair liquid chromatographic method for routine determination of the marker residue of oxytetracycline (OTC), namely OTC and 4-epi-oxytetracycline (4-epiOTC), in edible animal tissues (muscle, liver, kidney, and fat) has been developed. Minced tissue samples were acidified at pH 2.7 with 2 mol L−1 sulfuric acid and extracted with acetonitrile. The extracts were purified by treatment with ammonium sulfate solution and concentrated into 0.1 mol L−1 phosphoric acid. Baseline separation was carried out isocratically on a Nucleosil 100-5 C18, 5-μm column using an acetonitrile–0.01 mol L−1 disodium hydrogen phosphate (20:80, v/ v) mobile phase that contained both positively (tetrabutylammonium) and negatively (octanesulfonate) charged pairing ions and EDTA, and was adjusted to pH 3.8. Detection was by UV at 370 nm. The method was fully validated according to Commission Decision 2002/657/EC. Overall recoveries were better than 82.6% and overall relative standard deviation was better than 6% for all the tissues examined. The good analytical characteristics of the method allowed limits of quantification as low as 30 ng g−1 for muscle and fat and 50 ng g−1 for liver and kidney, for both OTC and 4-epiOTC, to be realized. The method was successfully used to determine the OTC marker residue in tissues of two sheep intramuscularly administered a commercial OTC formulation.
ACCESSION #
32127813

 

Related Articles

  • Understanding Split Peaks. Dolan, John W. // LC-GC North America;Dec2003, Vol. 21 Issue 12, p1134 

    Describes the problems involved in peak splitting in liquid chromatography separation. Occurrence of peak splitting; Number of peaks that are affected; Ways for correcting peak splitting; Sources of peak splitting; Methods for troubleshooting.

  • Phase Collapse in Reversed-Phase LC. Przybyciel, Matthew; Majors, Ronald E. // LC-GC Europe;Oct2002, Vol. 15 Issue 10, p652 

    Examines the topic of phase collapse in reversed-phase liquid chromatography. Problems that can be caused by phase collapse; Classic explanation of phase collapse with highly aqueous mobile phases; Wetting phenomenon for alkyl phases; Restoration of a column to its original state.

  • The Hazards of Adjusting Gradients. Dolan, John W. // LC-GC Europe;Nov2002, Vol. 15 Issue 11, p706 

    Explains that gradient elusion is a powerful tool that enables reversed-phased liquid chromatographers to obtain separations that are impossible with isocratic techniques. Need for analysts to be careful that they make no unintentional changes in the separation conditions; Importance of...

  • LC Columns --- The Top-10 List. Dolan, John W. // LC-GC Europe;Apr2003, Vol. 16 Issue 4, p196 

    Lists tips on the care and use of liquid chromatography columns. Use in-line filters; Importance of flushing columns regularly; Need to control temperature; Use guard columns; Minimization of garbage.

  • Process Purification of Polypeptides and Proteins by Reversed-Phase Column Chromatography. Lu, Philip; Carr, C. David; Chadwick, Paul; Li, Michael; Harrison, Kervin // BioPharm International;Sep2001, Vol. 14 Issue 9, p28 

    Discusses misconceptions about the use of process-scale reversed-phase chromatography for purification of polypeptides and proteins. Misconceptions about denaturation and cost; Recommendation of reversed-phase high-performance liquid chromatography (RP-HPLC); Tools that process development...

  • Separation is faster and more efficient.  // Food Engineering & Ingredients;Dec2000, Vol. 25 Issue 6, p43 

    Focuses on the usefulness of Chromalith High Performance Liquid Chromatography Columns in liquid chromatography in Germany. Efficiency on mixture separation processes; Solution to back pressure problems; Utilization of a solid silica rod.

  • An Organic Solvent-Free Method for Determining Oxytetracycline in Cow's Milk. Furusawa, Naoto // LC-GC North America;Apr2003, Vol. 21 Issue 4, p362 

    Reports on the development of an organic solvent-free method for the determination of oxytetracycline residue in cow's milk using high performance liquid chromatography. Use of photodiode-array detector and homogenizing extractor; Average recoveries of oxytetracycline; Relative standard...

  • Now What's Going On? Dolan, John W. // LC-GC North America;Jun2003, Vol. 21 Issue 6, p540 

    Answers questions related to troubleshooting of liquid chromatography. Source of a negative peak in chromatograms; Column pressure buildup; Separation deterioration.

  • Why Do Peaks Tail? Dolan, John W. // LC-GC North America;Jul2003, Vol. 21 Issue 7, p612 

    Discusses information related to the occurrence of peak tailing during separation and liquid chromatography processes. Definition of peak tails; Measurement of peak tailing; Potential problems created by tailing peaks; Causes of peak tailing.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics