Finite element studies of reinforced concrete slab - edge column connections with openings

AUTHOR(S)
Hong Guan; Polak, Maria Anna
PUB. DATE
August 2007
SOURCE
Canadian Journal of Civil Engineering;Aug2007, Vol. 34 Issue 8, p952
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
An extended nonlinear layered finite element method (LFEM) is used to investigate the influence of openings and shear stud reinforcement (SSR) on the behaviour of reinforced concrete slab – edge column connections. In all, ten large-scale slab – edge column connections tested previously are analyzed. The laboratory test variables were the size and location of the openings in the vicinity of an edge column and the existence of SSR. The numerical results of the load–deflection response, the ultimate strength, and the crack patterns are compared with the experimental findings and good agreement is achieved. A numerical study on two connections is also carried out to determine the influence of the locations of opening in slab – edge column connections with SSR. Discussion on code provisions for slabs with openings is provided. The comparative and numerical studies confirm the accuracy, reliability, and effectiveness of the LFEM in the analysis of slab – edge column connections with both openings and SSR.
ACCESSION #
32079729

 

Related Articles

  • Structural Modeling and Analysis of Concrete Floor Slabs. Aalami, Bijan O. // Concrete International;Dec2005, Vol. 27 Issue 12, p39 

    This article discusses the similarities and differences between traditional frame methods and finite element methods for the design of floor slab systems. In the discussion, it will be illustrated that the finite element method has the greatest potential for being able to automate this design...

  • STATISTICAL ANALYSIS OF DESIGN CODES CALCULATION METHODS FOR PUNCHING SHEER RESISTANCE IN COLUMN-TO-SLAB CONNECTIONS. Zabulionis, Darius; Šakinis, Dainius; Vainiūnas, Povilas // Journal of Civil Engineering & Management;2006, Vol. 12 Issue 3, p205 

    This paper analyses the compliance of the design codes calculation methods for punching shear resistance in reinforced concrete slabs STR 2.05.05:2005, E DIN 1045-1, ENV 1992-1-1 EC 2, prEN 1992-1 [Final draft] EC 2, Model Code CEB-FIP 1990, BS 8110, ACI 318-99 to the experimental data. It has...

  • BOLLARDS BATTLE BUILDING ENCROACHMENTS.  // Government Product News;Apr2004, Vol. 43 Issue 4, p41 

    Features the Model B1838 movable bollard from Doty and Sons Concrete Products Inc. Size and weight of the bollard; Use of the bollards; Types of available bollards from the company.

  • Analysis of Concrete Slabs Using Shell Element with Assumed Strain. Teng, Susanto; Yu Liu; Chee-Kiong Soh // ACI Structural Journal;Jul/Aug2005, Vol. 102 Issue 4, p515 

    In this paper, a layered degenerated shell element was adopted for finite element analysis of reinforced concrete slabs in combination with a three-dimensional continuum model based on a space truss concept for concrete. The space truss based model combined the uniaxial stress-strain...

  • Time-Dependent Deflection and Deformation of Reinforced Concrete Flat Slabs--An Experimental Study. Gamble, William L. // ACI Structural Journal;Mar/Apr2006, Vol. 103 Issue 2, p304 

    Comments on the article "Time-Dependent Deflection and Deformation of Reinforced Concrete Flat Slabs--An Experiment," by R. I. Gilbert and X. H. Guo published in the May to June 2005 issue of the "ACI Structural Journal." Concerns raised by the author over time-dependent deflections; Problems...

  • A Review of Soft Techniques for Electromagnetic Assessment of Concrete Condition. Queiroz, F. A. A.; Vieira, D. A. G.; Travassos, X. L.; Pantoja, M. F. // Mathematical Problems in Engineering;2012, Vol. 2012, Special section p1 

    This paper describes some efforts to design more efficient analysis for the GPR raw-data interpretation. Such analysis requires algorithms by which problems having complex scattering properties can be solved as accurately and as quickly as possible. This specification is difficult to achieve...

  • A Review of Soft Techniques for Electromagnetic Assessment of Concrete Condition. Queiroz, F. A. A.; Vieira, D. A. G.; Travassos, X. L.; Pantoja, M. F. // Mathematical Problems in Engineering;2012, Vol. 2012, Special section p1 

    This paper describes some efforts to design more efficient analysis for the GPR raw-data interpretation. Such analysis requires algorithms by which problems having complex scattering properties can be solved as accurately and as quickly as possible. This specification is difficult to achieve...

  • When to Begin Block Construction on a Slab Edge.  // Concrete Construction;Mar2011, Vol. 56 Issue 3, p86 

    The article provides an answer to a question of how fast can a block wall construction start on the border of a concrete slab base.

  • Out of Plumb Precast Panels.  // Concrete Producer;Aug/Sep2012, Vol. 30 Issue 5, p12 

    The article describes an option to remedy panels that were out of plumb but which cannot be replaced. A project involving the installation of 600 panels is described including the collaborative efforts of the parties involved in resolving the damage caused by the panels being out of plumb...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics