TITLE

A general approach to evaluating agreement between two observers or methods of measurement from quantitative data with replicated measurements

AUTHOR(S)
Haber, Michael; Barnhart, Huiman X.
PUB. DATE
April 2008
SOURCE
Statistical Methods in Medical Research;Apr2008, Vol. 17 Issue 2, p151
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We present a general approach to the definition and estimation of coefficients for evaluating agreement between two fixed methods of measurements or human observers. The measured variable is assumed to be continuous with a finite second moment. No other distributional assumptions are made. We introduce the term 'disagreement function' for the function of the observations that is used to quantify the extent of disagreement between the two measurements made on the same subject. The proposed inter-methods agreement coefficients compare the disagreement between measurements made by different methods on the same subject to the corresponding disagreement between replicated measurements made by the same method. Therefore, the new coefficients require data with replications readings. We propose inter-methods agreement coefficients for two practical situations involving two methods that have a measurement error: 1) comparison of a new method to a gold standard (or a reference method), and 2) comparison of two methods where neither method is considered a gold standard. We consider three disagreement functions based on the differences between two measurements: 1) the mean squared difference, 2) the mean absolute difference and 3) the mean relative difference. We then derive non-parametric estimates for the various agreement coefficients. Our approach is illustrated using data from a study comparing systolic blood pressure measurements by a human observer and an automatic monitor. The performance of the new estimates is assessed via stochastic simulations.
ACCESSION #
32055797

 

Related Articles

  • Further Traps to Blood Pressure Measurement. Bianchi, Edgardo H. // Texas Heart Institute Journal;2013, Vol. 40 Issue 4, p505 

    A letter to the editor is presented in response to the article on accurate blood pressure measurements.

  • ABC of hypertension: Blood pressure measurement. Beevers, Gareth; Lip, Gregory Y. H.; O'Brien., Eoin // BMJ: British Medical Journal (International Edition);04/28/2001, Vol. 322 Issue 7293, p1043 

    Presents a clinical review of blood pressure measurement. Use of the conventional sphygmomanometry technique of auscultatory blood measurement; History of various techniques; Recommendations for observer training.

  • ACCURATE BLOOD PRESSURE RECORDING: IS IT DIFFICULT? Bhalla, A.; Singh, R.; D'Cruz, S.; Lehl, S. S.; Sachdev, A. // Indian Journal of Medical Sciences;Nov2005, Vol. 59 Issue 11, p480 

    BACKGROUND: Blood pressure (BP) measurement is a routine procedure but errors are frequently committed during BP recording. AIMS AND SETTINGS: The aim of the study was to look at the prevalent practices in the institute regarding BP recording. The study was conducted in the Medicine Department...

  • Blood Pressure Monitors.  // American Family Physician;10/15/2004, Vol. 70 Issue 8, p1547 

    Provides information on how to monitor blood pressure. Reason people should measure their blood pressure at home; Advantages and disadvantages of aneroid monitor; Facts about digital monitor.

  • Evidence based management of hypertension: What to do when blood pressure is difficult to control. O'Rorke, Jane E; Richardson, W Scott // BMJ: British Medical Journal (International Edition);05/19/2001, Vol. 322 Issue 7296, p1229 

    Questions procedure of what to do when blood pressure is difficult to control. Consensus based on United States national guidelines for hypertensive patients with a specific blood pressure, but not for those for whom the target is an even lower pressure; Consideration of a selective, sequential...

  • M5-I blood pressure monitor.  // GP: General Practitioner;7/07/2003, p62 

    Focuses on the M5-I blood pressure monitor.

  • HEM705IT Omron BP monitor.  // GP: General Practitioner;4/14/2003, p86 

    The article presents information regarding blood pressure monitoring device.Comes supplied with software to transfer the memory of the blood pressure monitor to your PC.Optional compact printer will provide hard copies of individual or stored readings directly from the monitor.

  • Oscillometric Blood Pressure Measurement: The Methodology, Some Observations, and Suggestions. Jilek, Jiri; Fukushima, Teiichiro // Biomedical Instrumentation & Technology;May/Jun2005, Vol. 39 Issue 3, p237 

    Most noninvasive blood pressure (NIBP) devices use the oscillometric method. Published studies of oscillometric methodology introduced varied algorithmic approaches for determination of systolic (SBP), diastolic (DBP), and mean arterial (MAP) blood pressures. While there is a general agreement...

  • Blood pressure variability and multiple organ damage in primary hypertension. Leoncini, G; Viazzi, F; Storace, G; Deferrari, G; Pontremoli, R // Journal of Human Hypertension;Nov2013, Vol. 27 Issue 11, p663 

    Organ damage (OD) is an indicator of increased cardiovascular risk. Blood pressure variability (BPV) is related to greater incidence of events, regardless of the severity of hypertension. We investigated the relationship between ambulatory blood pressure monitoring (ABPM)-derived indices of BPV...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.