TITLE

Value of 3D fluoroscopic imaging of acetabular fractures comparison to 2D fluoroscopy and CT imaging

AUTHOR(S)
Kendoff, D.; Gardner, M. J.; Citak, M.; Kfuri Jr., M.; Thumes, B.; Krettek, C.; Hüfner, T.
PUB. DATE
June 2008
SOURCE
Archives of Orthopaedic & Trauma Surgery;Jun2008, Vol. 128 Issue 6, p599
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Intraoperative two-dimensional (2D) fluoroscopy of acetabular fractures is difficult due to the complex three-dimensional (3D) anatomy. Intraoperative 3D fluoroscopy may have particular utility in the evaluation of acetabular fractures. We compared the accuracy of 3D fluoroscopic imaging in evaluating acetabular fracture displacement and implant placement with fluoroscopy and computed tomography (CT) scans. In 24 cadaveric acetabuli, a transverse acetabular fracture was created. First a 2 mm step-off of the articular surface was created and reconstruction plates placed on the anterior and posterior columns. In 12 specimens, two screws were placed intraarticularly, protruded by 2 mm. In the remaining 12 specimens, the same constructs were used but the screws remained extraarticular. Second tests were designed to simulate an impaction injury. After hardware removal, a hollow trephine (diameter of 14.9 mm) was used to core a bonecyliner on the dome of the acetabulum, and impacted until it was recessed into the articular surface by 2 mm. Plates were placed, and screws were placed intraarticularly in 12 specimens, as in the first set of tests. All cadavers were imaged with standard 2D-, 3D fluoroscopy and CT. Three observers randomly evaluated all imaging studies for all specimens. For detection of intraarticular screws, both the Iso-C3D and the CT scans were significantly more sensitive (96 and 96%, respectively) and specific (96 and 100%, respectively) in detecting the intraarticular position compared to 2D fluoroscopy (75%; P < 0.05). Sensitivity of articular step-off detection was no different between the Iso-C3D (83%), CT (79%), and 2D fluoroscopy (87%). Articular impaction was correctly identified in 79% of specimens with the Iso-C 3 D technique, while the CT was accurate in 92%. 2D fluoroscopy was accurate in 62% for the impactions ( P < 0.05 vs. CT). 3D-fluoroscopic imaging appears to be extremely accurate in evaluating acetabular fracture constructs. Its sensitivity and specificity for evaluating intraoperative hardware was greater than with 2D fluoroscopy and equivalent to CT scan. Volumetric impactions were also reliably demonstrated on both of the 3D modalities, which were both superior to 2D fluoroscopy. Overall, Iso-C3D multiplanar imaging yields information regarding implant placement and articular reduction that is more detailed and accurate than standard fluoroscopy and is comparable to CT.
ACCESSION #
31722156

 

Related Articles

  • RATIONAL IMAGING. O'Connor, Philip J. // BMJ: British Medical Journal (International Edition);9/15/2007, Vol. 335 Issue 7619, p563 

    The article presents an overview of the tests which are available to doctors to help diagnosis a fractured hip. A discussion of the benefits and drawbacks which are associated with radiographs, bone scintigraphy, ultrasound, computed tomography and magnetic resonance imaging, is presented. The...

  • On the Reduction of Side Effects in Tomography. Masilamani, V.; Vanniarajan, C.; Krithivasan, Kamala // International Journal of Biomedical Sciences;2007, Vol. 2 Issue 4, p216 

    As the Computed Tomography(CT) requires normally hundreds of projections to reconstruct the image, patients are exposed to more X-ray energy, which may cause side effects such as cancer. Even when the variability of the particles in the object is very less, Computed Tomography requires many...

  • A targeted viewing. Casci, Tanita // Nature Reviews Genetics;Jun2006, Vol. 7 Issue 6, p412 

    Discusses research being done on a hybrid vector for ligand-directed tumor targeting and molecular imaging. Reference to a study done by A. Hajitou et al, published in the 2006 issue of "Cell"; Development of a tool that would integrate tumor targeting and molecular-genetic imaging; Use of a...

  • Evaluation of subjective assessment of the low-contrast visibility in constancy control of computed tomography. Thilander-Klang, Anne; Ledenius, Kerstin; Hansson, Jonny; Sund, Patrik; Båth, Magnus // Radiation Protection Dosimetry;Apr2010, Vol. 139 Issue 1-3, p449 

    The purpose of the present work was to investigate the reliability of subjective assessments of the low-contrast visibility in constancy control of computed tomography (CT). Axial CT images of a low-contrast phantom were acquired on an 8-slice multi-detector CT scanner at nine tube current...

  • Case report: drug interference with MIBG uptake in a patient with metastatic paraganglioma. Zaplatnikov, K.; Menzel, C.; Döbert, N.; Hamscho, N.; Kranert, W. T.; Gotthard, M.; Behr, T. M.; Grünwald, F. // British Journal of Radiology;Jun2004, Vol. 77 Issue 918, p525 

    Metaiodobenzylguanidine (MIBG) labelled with iodine-131 ((131)I) has become a well established therapeutic tool for inoperable metastastic tumours of paraganglioma. There are different pharmacological substances known to interfere with MIBG-uptake which may result in a false negative MIBG scan....

  • Quantification of Aortic Valve Calcification. Abildgaard, A. // Acta Radiologica;Sep2005, Vol. 46 Issue 6, p556 

    Introduces the themes of the research papers featured in the September 2005 issue of the journal "Acta Radiologica." Introduction of a scoring system for coronary arterial calcification; Relationship between the progression of calcification and stenosis; Evaluation of aortic valve calcification...

  • Computerized Axial Tomography (CT) Scans.  // New Harvard Guide to Women's Health;2004, p159 

    Presents a woman's guide to computerized axial tomography scans, also known as CAT or CT scan, an x-ray technique that are useful in evaluating tumors, infections and injuries. Details of the procedure; Risks and complications.

  • Actual diagnostic approach to the acute stroke patient. Lövblad, Karl-Olof; Baird, Alison E. // European Radiology;Jun2006, Vol. 16 Issue 6, p1253 

    Since acute stroke is now considered a potentially treatable medical emergency, a rapid and correct diagnosis must be made. The first step is to exclude hemorrhage, then to visualize any early ischemic changes, demonstrate the presence of hypoperfusion and locate the presence of a vascular...

  • Automatic exposure control in computed tomography – an evaluation of systems from different manufacturers. Söderberg, Marcus; Gunnarsson, Mikael // Acta Radiologica;Jul2010, Vol. 51 Issue 6, p625 

    Background: Today, practically all computed tomography (CT) systems are delivered with automatic exposure control (AEC) systems operating with tube current modulation in three dimensions. Each of these systems has different specifications and operates somewhat differently. Purpose: To evaluate...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics