TITLE

Alignment Deviation Between Bone Resection and Final Implant Positioning in Computer- Navigated Total Knee Arthroplasty

AUTHOR(S)
Catani, Fabio; Biasca, Nicola; Ensini, Andrea; Leardini, Alberto; Bianchi, Luca; Digennaro, Vitantonio; Giannini, Sandro
PUB. DATE
April 2008
SOURCE
Journal of Bone & Joint Surgery, American Volume;Apr2008, Vol. 90-A Issue 4, p765
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Computer-navigated total knee arthroplasty is aimed at improving accuracy in the positioning of prosthetic components and realigning the lower limb. The optimal position and orientation of the bone resection planes are targeted by the navigation system, but, after these are obtained, additional manual surgical actions, which may considerably affect final component alignment, are necessary for implantation. The aim of this study was to measure the alignment deviation caused by standard impaction of the tibial and femoral components following bone resections with use of navigation control. Methods: Ninety-one primary total knee arthroplasties were performed with an image-free knee navigation system. The alignment of the tibial and femoral bone resections was measured in three planes during surgery by the instrumented probe of the system. The alignment measure was repeated after final tibial and femoral component implantation with cement. The alignment deviations between the two measures were considered the positioning error associated with the final manual implantation of the components. Results: The alignment deviations between the bone resections and the subsequent implant placement were >10 in the frontal plane of the femur and in the frontal and sagittal planes of the tibia in 20%, 11%, and 33% of the patients, respectively. The deviations were >2° in 4%, 3%, and 9% of the patients, respectively. Deviations as large as 3° were found at the tibia in the sagittal plane (the posterior slope). Conclusions: Positioning of the femoral and tibial components in total knee arthroplasty, which mainly involves cementation and impaction of the final components, can introduce a considerable error in alignment, regardless of how accurately the resection planes are made. After computer-navigated total knee arthroplasty, it would be useful therefore to check the alignment of the prosthetic component carefully before the cement hardens.
ACCESSION #
31599979

 

Related Articles

  • Increased flexion position of the femoral component reduces the flexion gap in total knee arthroplasty. Matziolis, Georg; Hube, Robert; Perka, Carsten; Matziolis, Doerte // Knee Surgery, Sports Traumatology, Arthroscopy;Jun2012, Vol. 20 Issue 6, p1092 

    Background: The symmetry and equality of the flexion and extension gap are essential for successful endoprosthetic knee arthroplasty. Cruciate ligament sparing endoprosthetic designs are implanted with a measured resection technique, so that the posterior bone resection corresponds to the...

  • 'Spin-out' - eine vermeidbare Komplikation in der Knieendoprothetik. Magin, M.N. // Der Orthopäde;Feb2014, Vol. 43 Issue 2, p175 

    Spin out of a rotating polyethylene (PE) platform after total knee replacement leads to rotation of the bearing compared to the fixed metal components of the prosthesis at the femur and tibia of approximately 90°. This complication occurs only in prosthesis designs which do not have a...

  • Failure in the form of disassociation of a hinged total knee arthroplasty. Ioannidis, T. T.; Karamitros, A. E.; Stamatoukou, A.; Soucacos, P. N. // European Journal of Orthopaedic Surgery & Traumatology;May2005, Vol. 15 Issue 2, p173 

    Hinged total knee arthroplasty is a useful solution in cases of severe bone loss, ligamentous laxity and, of course, revision where these conditions are usually present. In revision arthroplasty, varying rates of success have been reported and the implants fail with symptoms of septic or aseptic...

  • Primary total knee arthroplasty using rotating-hinge prosthesis in severely affected knees. Yang, Jae-Hyuk; Yoon, Jung-Ro; Oh, Chi-Hun; Kim, Taik-Sun // Knee Surgery, Sports Traumatology, Arthroscopy;Mar2012, Vol. 20 Issue 3, p517 

    Purpose: A rotating-hinge total knee prosthesis may be utilized for the treatment of global instability or severe bone loss around the knee. The outcome of primary total knee arthroplasty (TKA) using Endo-Modell (Link) rotating-hinge prosthesis was evaluated. Methods: Retrospectively, review of...

  • Assessing patient-oriented results after revision total knee arthroplasty. Baier, Clemens; Lüring, Christian; Schaumburger, Jens; Köck, Franz; Beckmann, Johannes; Tingart, Markus; Zeman, Florian; Grifka, Joachim; Springorum, Hans-Robert // Journal of Orthopaedic Science;Nov2013, Vol. 18 Issue 6, p955 

    Background: Revision total knee arthroplasties (TKA) have been performed with increasing frequency over the last 25 years. Methods: In this study, we retrospectively analyzed 78 patients who underwent 78 revision TKAs during the years 2003–2007 with an average follow-up of 81 months...

  • Intramedullary versus extramedullary alignment of the tibial component in the Triathlon knee.  // Journal of Orthopaedic Surgery & Research;2011, Vol. 6 Issue 1, p44 

    The article reports on a research related to the alignment of tibial component. It states that prosthesis alignment plays a significant role in long term survivorship in total knee arthroplasty. It also informs that radiological alignment of tibial components is more accurate in the case of...

  • Early clinical outcomes of floating platform mobile-bearing TKA: longitudinal comparison with fixed-bearing TKA. Tae Kyun Kim; Chong Bum Chang; Yeon Gwi Kang; Byung June Chung; Hyung Joon Cho; Sang Cheol Seong // Knee Surgery, Sports Traumatology, Arthroscopy;Jul2010, Vol. 18 Issue 7, p879 

    This study was conducted to longitudinally compare a new floating platform mobile-bearing (MB) prosthesis with an established fixed-bearing (FB) system with respect to early clinical outcomes in patients with bilateral TKAs using the MB prosthesis in one knee and the FB prosthesis in the other....

  • Press-Fit Condylar Design Total Knee Arthroplasty. Rodricks, David J.; Patil, Shantanu; Pulido, Pamela; Colwell Jr., Clifford W. // Journal of Bone & Joint Surgery, American Volume;Jan2007, Vol. 89-A Issue 1, p89 

    Background: The Press-Fit Condylar total knee arthroplasty implant design has been used by many orthopaedic surgeons over the last twenty years. The design has survived with relatively minor modifications and remains a popular implant system today. The present study represents the fourteen to...

  • Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Kamat, Yogeesh; Aurakzai, Kamran; Adhikari, Ajeya; Matthews, Daniel; Kalairajah, Yegappan; Field, Richard // International Orthopaedics;Dec2009, Vol. 33 Issue 6, p1567 

    Computer navigation assistance in total knee arthroplasty (TKA) results in consistently accurate alignment of prostheses. We aimed to compare the outcome of computer-navigated and conventional TKA and to analyse the radiologically malaligned knees. We analysed 637 primary TKA, carried out by a...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics